首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 672 毫秒
1.
This report describes a fatal intoxication with two different drugs: clozapine and orphenadrine. A 38-year-old man was found dead in the bedroom of his residence. Near the body were found various empty pharmaceutical boxes, employed in schizophrenic therapy, two of them containing clozapine and orphenadrine. High concentrations of clozapine and orphenadrine detected in blood, urine and gastric content were related to death. These compounds were identified and quantitated by liquid-liquid extraction followed by gas chromatographic/mass spectrometry (GC/MS) analysis.  相似文献   

2.
A screening method for detecting volatile hydrocarbons in blood has been developed using gas chromatography/mass spectrometry with a wide-bore capillary column and a headspace method. Toluene-d8 and indan were used as the internal standards for quantitative analysis. Hydrocarbons with retention indices from 600 to 1200 were simultaneously and quantitatively detected in relatively low concentrations (0.01 microgram/ml) in reconstructed ion chromatography. This method could prove useful in forensic cases in which urgent examination of complex hydrocarbon mixtures, e.g. petroleum components, is required.  相似文献   

3.
Benzoylecgonine (BE) was detected in hair samples using nonproprietary extraction methodology and modifications of well-established radioimmunoassay (RIA) screening/quantitative gas chromatography/mass spectrometry (GC/MS) confirmation procedures. Samples collected anonymously from a population of 48 jail detainees weighed between 5.3 and 61.2 mg. All of the 22 hair samples which had RIA results indicating the presence of BE or immunologically similar substances above a cutoff amount of 1.25 ng/sample (50 ng/mL) were confirmed by GC/MS. Several varieties of hair color and texture were tested, although in each general category there were samples which contained BE as well as other samples which did not reveal detectable amounts of BE. The range of concentrations in 22 hair extracts that screened positive were 0.26 to 18 ng/mg hair as determined by GC/MS. In comparison with other reports of cocaine-related substances in hair, these data show consistent concentrations.  相似文献   

4.
Two cases of fatal intoxications with toluene due to glue sniffing are described. In case 1, the autopsy did not indicate cause of death, while in case 2, the cause of death was determined to possibly be due to mechanical asphyxia by drowning. As the decedents had a history of glue sniffing, toxicological analyses were performed. Using gas chromatography with flame ionization detector and gas chromatography/mass spectrometry (GC/MS) with headspace method, toluene was detected in biological samples. Toluene ranged from 3.81 to 20.97 μg/g, with the highest concentrations observed in liver and brain (13.82–20.97 μg/g) in both cases. Based upon this data, the cause of death in both cases was determined to be toluene poisoning. Toxicological investigations are extremely important and should be considered mandatory in all deaths thought to be due to volatile substance abuse, as well as all deaths that are thought to be due to poisoning in young people.  相似文献   

5.
We describe four fatal cases due to ingestion of carbofuran, a carbamate insecticide. Carbofuran was detected in the gastric contents using thin layer chromatography (TLC) and gas chromatography/mass spectrophotometry (GC/MS), and quantified in the blood using a gas chromatograph equipped with nitrogen-phosphorus detector (NPD). Fatal concentrations of carbofuran in blood ranged from 0.32 to 11.6 microg/ml.  相似文献   

6.
陈斌  雷霖 《刑事技术》2006,(5):14-15
目的建立GC/MS分析被焚烧人体内脏组织中氯氮平的方法。方法采用试管超声提取、三氯甲烷浸提苯溶解、过柱净化的方法,以岛津QP5050ADB-5MS石英毛细柱分析结果。结果成功检出被焚烧人体内脏组织中氯氮平成分。结论该方法操作简单,准确可靠,适用于中毒及临床药物观察。  相似文献   

7.
Two techniques for analyzing contaminants released as gases from postmortem tissues were described and compared. One technique used gas chromatography/mass spectrometry (GC/MS); the other, infrared spectroscopy (IR). Brain, lung, liver, blood and urine specimens were obtained from suspected drug-overdose victims whose deaths were contributed to or caused by inhalation of unknown gases or vapors during the period immediately preceding death. Gases from the postmortem tissues and liquid samples were separately admitted into an evacuated IR gas cell, the IR spectra recorded, and gas samples then removed for GC/MS analysis. Nitrous oxide, glue, and paint solvent constituents were identified and measured. Only the brain and lung tissues contained measurable amounts of inhalants. Both IR and GC/MS methods were adequate for normal confirmatory analyses; the GC/MS system was judged superior for fast routine efforts normally hampered by incomplete sample history.  相似文献   

8.
Poisoning with volatile substances remains exceptional. Authors report the case of a married couple who were found in a car with a butane gas bottle: the woman was dead and her husband alleged it was an unsuccessful suicide pact. A specific research of volatile substances on postmortem samples with headspace gas chromatography–mass spectrometry following a quantitative determination was performed. The n‐butane concentrations detected were composed of 610 μg/L (cardiac blood), 50 μg/kg (brain), 134 μg/kg (lungs), 285 μg/kg (liver), and 4090 μg/kg (heart) and were compatible with the rare lethal concentrations evoked in the literature. The cause of death was determined to be asphyxiation through n‐butane criminal poisoning. Authors recommendation therefore is to take samples immediately and place them in properly sealed containers and hence analyzing the samples as soon as possible after collecting them or storing them under ?30°C (?22°F) if analyses cannot be performed immediately.  相似文献   

9.
To establish a method for the routine analysis of carboxyhemoglobin (COHb) in autopsy materials including those which have undergone postmortem changes, e.g. thermo-coagulation, putrifaction and contamination, an automated head-space gas chromatography/mass spectrometry (GC/MS) analysis was utilized. The procedure consisted of preparation of the sample in a vial and a carbon monoxide (CO) saturated sample, for estimation of hemoglobin content, in another vial, the addition of n-octanol, potassium ferricyanide and an internal standard (t-butanol), GC separation and determination of CO using a GC/MS system equipped with an automated head-space gas sampler. The method was practical not only with the blood and bone marrow aspirates to confirm the findings on the CO-oximeter system, but also with the thermo-coagulated and putrified blood.  相似文献   

10.
血中十六种挥发性碳氢化合物的固相微萃取   总被引:1,自引:0,他引:1  
为认定火灾现场烧死尸体 ,用固相微萃取技术从血中快速提取十六种碳氢化合物 (直链烃从八碳到十三碳 ,芳香烃从二甲苯异构体到三甲基苯 )。在室温条件下直接用 10 0 μm 聚二甲基硅氧烷萃取头以顶空方式萃取浓缩2 0min。气相色谱仪 ,氢火焰检测器测定 ,外标法定量。结果显示 :血中检测浓度可达 0 1μg/ml。固相微萃取是筛选血中碳氢化合物一种灵敏而准确的方法。  相似文献   

11.
Abstract:  Three cases are reported of elevated postmortem blood morphine concentrations (189–3036 ng/mL) that were observed during the course of death investigations involving three children ranging in age from 1 week to 2 years, all of whom underwent withdrawal of life support. In all three cases, the presence of opiates in postmortem blood was indicated by immunoassay (ELISA) and quantitative confirmatory analysis of free morphine concentrations in postmortem blood was performed by solid-phase extraction followed by gas chromatography/mass spectrometry (GC/MS) in the selected ion monitoring mode. While the practice of withdrawing life support from terminally ill patients, with the accompanying administration of narcotics/analgesics has been reported in the medical literature, it has not been adequately described in the forensic literature. The implications of this practice on the forensic toxicological interpretation of morphine findings are discussed. To our knowledge, this is the first report of postmortem morphine concentrations arising directly from administration in conjunction with withdrawal of care in pediatric patients.  相似文献   

12.
In contrast to typical autoerotic fatalities, when death is due to asphyxia mostly by mechanical compression of the neck, atypical autoerotic accidental deaths (AADs) involve sexual self-stimulation by other means such as electrocution or inhalation of chemical agents. Especially in lethal cases of volatile substance abuse (VSA), a differentiation between suicide or sexually or nonsexually motivated accident is often complicated in practical casework. Considering the small number of AADs involving chemical substance abuse reported in the literature, the number of unreported cases seems to be very high. We report about 5 lethal cases of VSA; analysis was performed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC/MS). When headspace sampling is not performed at autopsy, the analysis of volatile substances can be very complicated. In 2 cases, an AAD was diagnosed considering findings at the scene, reconstruction of the event, and discussion of the circumstances of the death. These findings demonstrate the importance of VSA in atypical autoerotic asphyxia. Therefore, in cases of suspected lethal inhalational intoxications, as a matter of principle, headspace asservation should be performed at autopsy and an autoerotic motivational background should be taken into consideration for differential diagnosis.  相似文献   

13.
When a forensic toxicologist interprets postmortem blood cocaine findings he usually must make assumptions regarding perimortem drug concentrations. In-vitro studies have shown that cocaine rapidly hydrolyzes in unpreserved blood, particularly at elevated temperatures. However, other studies have demonstrated site-dependent postmortem release of some drugs from tissue stores accompanied by increases in drug concentrations in the blood. This study was undertaken to investigate whether blood cocaine concentrations change in the body during the postmortem interval and, if so, to measure the direction and magnitude of the changes. In medical examiner cases in which scene investigation suggested that the decreased was a cocaine user, blood samples were collected as soon after death as possible. At autopsy, a second set of samples was collected. Analysis of paired samples by gas chromatography/mass spectrometry (GC/MS) revealed dramatic differences in the cocaine concentration. The magnitude and direction of the change appears to be site dependent. Usually, but not invariably, cocaine concentration in subclavian vein blood decreases while that in heart, aorta, and femoral vein blood increases during the interval between death and autopsy. The findings emphasize the danger inherent in attempting to estimate the concentration of cocaine in blood at the time of death from postmortem data.  相似文献   

14.
Seven cases involving acute fatalities due to ingestion of furathiocarb, a carbamate insecticide, are presented. Furathiocarb was detected in the gastric contents using thin layer chromatography (TLC) and gas chromatography/mass spectrophotometry (GC/MS), and quantified in the blood using a gas chromatograph equipped with a nitrogen-phosphorus detector (NPD). The fatal levels of furathiocarb in the blood ranged from 0.1 to 21.6 micrograms/ml.  相似文献   

15.
《Science & justice》2022,62(2):193-202
Cyanide is a powerful and rapidly acting poison. In Japan, cyanide poisoning is rare, and regular cyanide testing can be costly and time consuming. In contrast, alcohol analysis is routinely performed in most forensic laboratories. In this study, we attempted to develop a method for the simultaneous quantification of cyanide and alcohols in blood using headspace gas chromatography (HS–GC). As nitrogen-phosphorus detection (NPD) is more sensitive to hydrogen cyanide than mass spectrometry (MS), a Deans switch was used to switch the detectors during a single run. The separation provided by three analytical columns, PoraBOND Q, CP-Sil 5 CB, and HP-INNOWax, was investigated, and PoraBOND Q was selected. The use of HS–GC–MS/NPD with a Deans switch enabled the simple and simultaneous quantification of cyanide, ethanol, and 1-propanol. Eighteen other volatile compounds were detected in the SIM/scan mode of the MS.  相似文献   

16.
A reliable and sensitive method to analyze thiamylal in biological materials was developed, using gas chromatography/mass spectrometry (GC/MS). A quantitative determination was made by use of mass fragmentography with the lower detection limit of 0.01 microgram/g. Thiopental was used as the internal standard. Distribution of the drug in the blood and body tissues of rats was examined. The method was then used to detect thiamylal in tissues from an autopsied patient and concentration of this drug in the body materials was evaluated, from medico-legal aspects.  相似文献   

17.
The aim of the study is to present the application of a headspace–gas chromatography–mass spectrometry (HS‐GC‐MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS‐GC‐MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.  相似文献   

18.
Author examined cadaver organs and bone samples (sternum, rib) of drug poisoning cases. Following suitable procedures, active drug components (amobarbital, glutethimide, and so forth) were identified by gas chromatography/mass spectrometry (GC/MS). Based on results of quantitative GC analysis, relationships were sought between the active agent concentrations measured in the organs and the bone samples.  相似文献   

19.
气相色谱-串联质谱法分析尿和血中除草剂百草枯   总被引:1,自引:1,他引:0  
目的建立尿和血中百草枯的离子交换固相萃取-气相色谱-串联质谱分析方法。方法尿样加内标乙基百草枯,用732阳离子交换树脂提取;血样加内标乙基百草枯,用三氯乙酸凝聚蛋白质后取上清液用732阳离子交换树脂提取。提取物用硼氢化钠在水溶液中碱性条件下还原,还原物用有机溶剂提取进行气相色谱-串联质谱法分析。结果尿和血中百草枯的提取率分别为76%和74%,检测限分别为2ng/mL和10ng/mL,尿添加百草枯100ng/mL和血添加百草枯500ng/mL水平的回收率分别为99.6±5.6%和99.3±7.6%(Mean±CV)。结论本文建立的分析方法灵敏度高,能够满足中毒致死案件检验及临床毒物检验的需要。  相似文献   

20.
A qualitative method for the determination of cocaine alone without its metabolites in human hair by gas chromatography/mass spectrometry (GC/MS) was developed. The assay used helium as carrier gas, a 30-m bonded phase fused silica OV-1 capillary column, and solid injection at 290 degrees C evaporator temperature. The cocaine concentrations in hair were determined also by radioimmunoassay (RIA). The values obtained are the sum of cocaine and its metabolites. Both GC/MS and RIA meet the requirements for the determination of drug abuse by two different methods in forensic science.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号