首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
GC and GC/MS analysis was used to detect cocaine and cocaethylene in hair extracts of mice injected with 20 mg/kg cocaine hydrochloride or an equivalent dose of cocaethylene fumarate twice daily for 3 weeks. Some mice were fed liquid Lieber-DeCarli diets containing ethanol (26% of total calories) and injected twice daily with the same doses of cocaine or cocaethylene or combination of cocaine and morphine (5 mg/kg). The average concentrations of cocaine in different experimental groups were in the range of 0.9-2.4 ng/mg of hair and for cocaethylene, 2.4-2.8 ng/mg of hair. There were no significant differences in hair concentrations of cocaine among groups receiving cocaine treatment, nor were there significant difference in cocaethylene concentration in hair in the two groups administered cocaethylene. In hair extracts of mice treated with cocaine and ethanol, levels of cocaethylene were below the limit of detection.  相似文献   

2.
Hair samples of eight postmortem cases were analyzed in segments of 1 to 3 cm for cocaine, benzoylecgonine and cocaethylene. Samples were prepared for analysis by digestion in 0.1 M HCl and subsequent extraction with mixed-mode solid-phase extraction columns. Measurement was made by reversed-phase, narrow-bore HPLC and fluorescence detection using two laboratory-made internal standards. The concentrations were in the region of 0.29-316 ng/mg of hair for cocaine, 0.43-141 ng/mg of hair for benzoylecgonine and 0.93-1.83 ng/mg of hair for cocaethylene. All eight investigated cases had cocaine-positive segments. In six of the cases, all segments were positive, suggesting regular cocaine use and two showed in-between negative segments indicating an interruption or a change of the abuse intensity. The results showed a second, remarkable observation, i.e. enormous concentration differences (factor >150) for both cocaine and benzoylecgonine between the different subjects. Furthermore, interindividual cocaine/benzoylecgonine ratios ranged from 0.02 to 8.43. We believe these observations could in part be attributed to both some of the still existing limitations in the analytical approach(es), especially the mandatory hair washing steps, and in our still too limited knowledge of the hair incorporation processes. Nevertheless, in some cases, segmental analysis proved to be an important tool to distinguish, together with postmortem examination, deadly chronic abuse from single acute drug overdosage.  相似文献   

3.
Hair samples of eight postmortem cases were analyzed in segments of 1 to 3 cm for cocaine, benzoylecgonine and cocaethylene. Samples were prepared for analysis by digestion in 0.1 M HCl and subsequent extraction with mixed-mode solid-phase extraction columns. Measurement was made by reversed-phase, narrow-bore HPLC and fluorescence detection using two laboratory-made internal standards. The concentrations were in the region of 0.29–316 ng/mg of hair for cocaine, 0.43–141 ng/mg of hair for benzoylecgonine and 0.93–1.83 ng/mg of hair for cocaethylene. All eight investigated cases had cocaine-positive segments. In six of the cases, all segments were positive, suggesting regular cocaine use and two showed in-between negative segments indicating an interruption or a change of the abuse intensity. The results showed a second, remarkable observation, i.e. enormous concentration differences (factor >150) for both cocaine and benzoylecgonine between the different subjects. Furthermore, interindividual cocaine/benzoylecgonine ratios ranged from 0.02 to 8.43. We believe these observations could in part be attributed to both some of the still existing limitations in the analytical approach(es), especially the mandatory hair washing steps, and in our still too limited knowledge of the hair incorporation processes. Nevertheless, in some cases, segmental analysis proved to be an important tool to distinguish, together with postmortem examination, deadly chronic abuse from single acute drug overdosage.  相似文献   

4.
In our laboratory, analysis of human hair for the detection of drugs of abuse was first performed in 1995. Initially, requests for hair analysis were few, and it is only since 1997 that these analyses have become routine. As demand grew, we developed an automatic solid-phase extraction method; the use of a robot ASPEC allowed us to drop certain fastidious manipulations, and to treat a large number of samples at a time. This method is described, along with analysis by gas-chromatography-mass spectrometry (GC/MS) in selected ion monitoring mode (SIM), for the following drugs: codeine, 6-monoacetylmorphine (6-MAM), morphine, cocaine, methadone, ecstasy (MDMA) and Eve (MDE). This requires prior derivatization with propionic anhydride. The different validation parameters, linearity, repeatability, recovery and detection limits are described, as well as the application of this method to some real cases. Analysis of these cases is also performed by an ion trap GC/MS in chemical ionization mode (GC/IT/CI/MS) in order to demonstrate the usefulness of this technique as a complement to routine analysis. Analysis by GC/IT/CI/MS indeed avoids the risk of false-positive results by the identification of metabolites.  相似文献   

5.
A procedure is presented for the simultaneous identification and quantification of morphine (MOR), codeine (COD), ethylmorphine (EM), 6-monoacetylmorphine (6-MAM), cocaine (COC), benzoylecgonine (BZE), ecgonine methylester (EME) and cocaethylene (CE), contained in the hair of opiates and cocaine addicts. The method involves decontamination in dichloromethane, pulverization in a ball mill, heat-acid hydrolysis, addition of deuterated internal standards, liquid-liquid extraction and gas chromatography/mass spectrometry (GC/MS) after silylation. The limit of detection (LOD) was ~0.1–0.8 ng/mg for each drug, using a 30-mg hair sample. The method is reproductible, with a coefficient of variation (CV) of ~8–17%. Cocaine and 6-monoacetylmorphine were the major compounds detected in cases of cocaine (14 cases) and heroin (68 cases) intake. Concentrations were in the range 0.4–78.4 ng/mg (COC), 0.0–36.3 ng/mg (BZE), 0.0–1.6 ng/mg (EME), 0.0–2.1 ng/mg (CE), 0.0–84.3 ng/mg (6-MAM), 0.2–27.1 ng/mg (MOR) and 0.1–19.6 ng/mg (COD). An application in forensic sciences, involving multi-sectional analysis, is given.  相似文献   

6.
GC/MS和GC法定性定量分析可卡因   总被引:1,自引:0,他引:1  
目的建立用于可卡因案件检验鉴定的GC和GC/MS定性、定量分析方法。方法通过选择和优化,建立GC、GC/MS法检验可卡因的最佳分析条件;用分别含0.6mg/ml地西泮为内标的0.10、0.20、0.40、0.60、0.80、1.00、1.20mg/ml可卡因标准品乙醇液,考察线性范围和方法检测限。结果分析方法线性方程:GC/FID,Y=1.055X-0.0021,R2=0.9999,GC/NPD,Y=0.556X-0.0016,R2=0.9996;可卡因检测限:GC/FID法10ng,GC/NPD法2ng;分别以所建GC/FID、GC/NPD分析方法和内标法对案件中缴获的可卡因毒品进行定量分析,结果为72%±2.3%,且两方法定量重现性良好。结论本文所建方法可以用于可卡因涉毒案件的检验鉴定。  相似文献   

7.
Toxicological evaluation of postmortem urine collected from a 41-year-old deceased white male detected anhydroecgonine ethyl ester (ethylecgonidine, AEEE), a transesterification product of smoked cocaine co-abused with ethanol. A solid phase extraction (SPE) method was used to extract cocaine, AEEE, and related metabolites from urine. SPE on a 1 mL urine sample from the decedent followed by GC-MS detected AEEE. Other metabolites identified by GC-MS included cocaine, cocaethylene, and anhydroecgonine methyl ester (AEME). To determine whether some or all of the AEEE was artifactually produced in the heated GC injector port, an alternative LC-MS method was developed. LC/MS following SPE found at least 50 ng/mL of AEEE in the extract. The mass fragmentation (MS/MS and MS3) of AEEE detected in the urine was compared to spectra of authentic, synthesized compound. AEEE is a potential additional forensic marker for the co-abuse of smoked cocaine and ethanol.  相似文献   

8.
When a forensic toxicologist interprets postmortem blood cocaine findings he usually must make assumptions regarding perimortem drug concentrations. In-vitro studies have shown that cocaine rapidly hydrolyzes in unpreserved blood, particularly at elevated temperatures. However, other studies have demonstrated site-dependent postmortem release of some drugs from tissue stores accompanied by increases in drug concentrations in the blood. This study was undertaken to investigate whether blood cocaine concentrations change in the body during the postmortem interval and, if so, to measure the direction and magnitude of the changes. In medical examiner cases in which scene investigation suggested that the decreased was a cocaine user, blood samples were collected as soon after death as possible. At autopsy, a second set of samples was collected. Analysis of paired samples by gas chromatography/mass spectrometry (GC/MS) revealed dramatic differences in the cocaine concentration. The magnitude and direction of the change appears to be site dependent. Usually, but not invariably, cocaine concentration in subclavian vein blood decreases while that in heart, aorta, and femoral vein blood increases during the interval between death and autopsy. The findings emphasize the danger inherent in attempting to estimate the concentration of cocaine in blood at the time of death from postmortem data.  相似文献   

9.
In a study of subjects in drug rehabilitation programs, cocaine and cocaine metabolite levels were determined in the hair of 75 subjects who had produced cocaine-positive urine results. The hair was analyzed after being washed with the 3.75 h wash procedure developed by this laboratory. In addition, results of testing 73 non-users are presented, as well as levels of cocaine, benzoylecgonine (BE), cocaethylene, and norcocaine from workplace population samples. The data support a recommendation of reporting as positive a sample with cocaine of 500 pg/mg hair and either a 5% ratio of benzoylecgonine (BE) to cocaine in samples, or the presence of cocaethylene at 50 pg/mg hair, or norcocaine at 50 pg/mg hair for samples < or =2000 pg cocaine/mg hair. For samples with cocaine present at >2000 pg/mg hair, the data indicate that a ratio of 5% BE may be an overly conservative approach. In appropriately washed hair samples, cocaine users can produce hair levels of <5% BE and thus a minimum BE cutoff in lieu of a ratio could be considered.  相似文献   

10.
Several samples of Colombian and a sample of Peruvian coca paste were subjected to chemical analysis to ascertain the complexity of these products. A neutral and acid fraction and a basic fraction were analyzed by gas chromatography/flame ionization detection (GC/FID) and gas chromatography/mass spectrometry (GC/MS). The basic fraction was also analyzed as its trimethylsilyl (TMS) derivative. Several gasoline residue components were identified in the neutral fraction. In addition to cocaine (greater than 60% in all cases), other alkaloids were identified. Lead and manganese analyses were carried out on these samples. While all the samples contained no lead (less than 45 ppm), most of the Colombian samples contained significant amounts of manganese (greater than 5%). Preliminary smoking experiments with a Colombian coca paste sample indicated that it behaves more like free cocaine than like a cocaine sulfate salt.  相似文献   

11.
Two techniques for analyzing contaminants released as gases from postmortem tissues were described and compared. One technique used gas chromatography/mass spectrometry (GC/MS); the other, infrared spectroscopy (IR). Brain, lung, liver, blood and urine specimens were obtained from suspected drug-overdose victims whose deaths were contributed to or caused by inhalation of unknown gases or vapors during the period immediately preceding death. Gases from the postmortem tissues and liquid samples were separately admitted into an evacuated IR gas cell, the IR spectra recorded, and gas samples then removed for GC/MS analysis. Nitrous oxide, glue, and paint solvent constituents were identified and measured. Only the brain and lung tissues contained measurable amounts of inhalants. Both IR and GC/MS methods were adequate for normal confirmatory analyses; the GC/MS system was judged superior for fast routine efforts normally hampered by incomplete sample history.  相似文献   

12.
A method for the simultaneous determination of cocaine (COC) and cocaethylene (CE) in human hair was developed, using solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) as analytical technique to identify and quantify the drugs. Selected ion monitoring (SIM) mode was used to obtain higher sensitivity. The deuterated-labeled analogues were used as internal standards. The detector response was linear for the drugs studied over the range 0.4-15 ng/mg, with correlation coefficients higher than 0.995. The coefficients of variation oscillated between 0.65% and 14.18% and the accuracy was in the range from 0.73% to 11.20%. The limits of quantitation and detection were found to be acceptable. Finally, this method was applied to 15 hair samples from cocaine users, obtaining positive results in all cases. The mean concentrations were 5.39 ng/mg (range: 0.43-8.98 ng/mg) for cocaine and 1.11 ng/mg (range: 0.42-2.23 ng/mg) for cocaethylene.  相似文献   

13.
DNA extracted from 33 postmortem muscle specimens was analyzed using MZ 1.3, a hypervariable minisatellite probe, as well as locus-specific minisatellite probes (g3, MS1 and MS43). After storage at -25 degrees C for 10 months, DNA from all the samples was partially (approximately 21% of total DNA) degraded even when autopsy was performed 1 day postmortem. However, more than 90% of DNA samples up to at least 3 days postmortem were suitable to obtain good restriction fragment length polymorphism (RFLP) patterns. When small strips of specimen were stored for 8 days at room temperature in moist chambers, approximately 42% of total DNA was degraded. Only 30% of these DNA samples still showed good RFLP patterns. However, no obvious relation between qualities of DNA analyzed by detection of RFLP and quantities of total and high-MW DNA became apparent. A case of familial relationship was ascertained by DNA fingerprints. Since DNA of good quality can be recovered from muscle tissues in large quantities, DNA extraction from muscle tissues and detection of RFLP patterns should be very useful for individual identification in autopsy cases.  相似文献   

14.
GC/MS研究海洛因代谢物在吸毒者体内的分布   总被引:5,自引:2,他引:3  
Xiang P  Shen M  Wu HJ  Huang ZJ 《法医学杂志》1999,15(4):208-210
应用GC/MS-SIM测定了海洛因代谢物吗啡在两例海洛因延缓死亡者的体内分布,并分析了收集到的7例案子的毛发(头发、腋毛和阴毛)中6-单乙酰吗啡和吗啡含量。生物检材和毛发经酸水解、提取、醋酸酐或双(三甲基硅基)三氟乙酰胺(BSTFA)衍生化,然后进行GC/MS-SIM分析。结果表明尿、胆汁和肝脏是判定死者是否曾使用海洛因的最佳检材;毛发分析与生物检材相比有其独特的优点,可提供数月甚至数年的用药情况。为公安司法机关打击吸毒、惩治犯罪提供更可靠、有效的证据。  相似文献   

15.
The evaluation of drug abuse in a defined population was performed through toxicological hair analysis. Hair samples from university students ranging from 18 to 25 years of age were anonymously collected and screened for cocaine, amphetamines and cannabinoids by radioimmunoassay (RIA). Positive results (cut-off values adopted were 2 ng/mg for cocaine and amphetamines and 0.5 ng/mg for cannabinoids) were confirmed by GC/MS. Preliminary results showed 19% of positive results for cocaine on 200 samples analysed. No confirmed positive results were obtained for amphetamine analysis. RIA technique demonstrated its unsuitability for cannabinoids preliminary screening on hair, giving a high percent of false positive results.  相似文献   

16.
The analysis of hair for drugs of abuse is becoming increasingly popular and is under consideration by the Division of Health and Human Services as a possible alternative or adjunct to urinalysis in workplace programs. The detection of cocaine in human hair using a commercially available micro-plate enzyme immunoassay is described for the first time. Sample size and incubation time were the major variables in the optimization of the method. In order to validate the procedure, the method was applied to 105 consecutive hair samples routinely received into our laboratory. The samples were simultaneously analyzed by the Micro-Plate immunoassay (EIA), as well as our current fluorescence polarization immunoassay (FPIA) procedure and gas chromatography-mass spectrometry (GC/MS). The sensitivity of the EIA and FPIA assays were 75% and 67.8% respectively; specificity 97.4% and 80.5% respectively; and efficiency 91.4 and 77.1% respectively. The Micro-Plate EIA was shown to be a valid alternative to other immunoassay screening methods for the detection of cocaine in hair by demonstrating increased sensitivity, specificity and efficiency over our current technique.  相似文献   

17.
In an effort to improve laboratories performing hair analysis in forensic cases, the French Society of Analytical Toxicology (S.F.T.A.) has implemented a proficiency testing program since 1992. Actually about 10 laboratories are participating. Each survey is dedicated to one analyte or one pharmacological class: opiates (6-monoacetylmorphine, morphine and codeine), cocaine and benzoylecgonine, tetrahydrocannabinol, buprenorphine and norbuprenorphine, beta-blockers (metoprolol, atenolol), beta 2-agonists (salbutamol, clenbuterol). Animal hair was tested for clenbuterol. Prior to sending, hair samples were reduced to a powdered form, well mixed to ensure homogeneity, and then tested by GC/MS or HPLC/MS. Results confirm those obtained in a preliminary study on opiates and cocaine analysis in hair: a common analytical procedure has to be used by all the participants, including hydrolysis of hair. It is essential to work on authentic drug-positive hair samples and not on spiked samples. Participation at this program is free of charge and considered as an educational tool. Comparison of the results with those of other laboratories in Europe and USA shows that the analytical methods used during this program are in accordance with all the other procedures.  相似文献   

18.
An ingestion of an unknown quantity of Ivadal (zolpidem) tablets in a case of drug abuse is described. The authors report a new and fast method of analysing and determining the zolpidem concentration in postmortem specimens. Quantitation of zolpidem was performed by ethyl acetate extraction from alkalinized body fluids before GC/MS analysis. The analyses were performed without any complex sample clean-up steps and with little sample material. Postmortem concentrations of zolpidem in body fluids are given. The proposed method is a rapid procedure of analysis in cases of deliberate poisoning with the sedative-hypnotic drug, zolpidem.  相似文献   

19.
目的采用液-液萃取、衍生化和GC/MS、GC/NPD方法,进行毛发中氯胺酮定性定量分析。方法选择4-苯基丁胺为内标,毛发样本用NaOH、HCl及芳基硫酸酯酶/β-葡萄糖醛酸酶等3种方式进行水解,再进行衍生化后,采用GC/MS和GC/NPD方法定性定量分析。对不同水解和衍生化条件以及提取溶剂进行比较优化,并考察方法精密度、稳定性和检出限。结果方法的提取回收率大于95%,精密度和样品稳定性良好,日内和日间标准偏差小于6%;采用GC/NPD和GC/MS直接分析毛发中的氯胺酮,检出限为0.2ng/mg和2.0ng/mg,线性范围为10.0~250.0ng/mg,相关系数均大于0.99;采用酰化衍生化后分析,GC/NPD和GC/MS检出限分别提高至0.1ng/mg和0.2ng/mg。结论该方法回收率高、检测限低,可以用于毛发中氯胺酮的定性定量分析检验。  相似文献   

20.
The objective of this study was to develop a two-step strategy for analysis of opiates and cocaine in hair samples involving an immunological screening procedure followed by confirmation of results using gas chromatography-mass spectrometry (GC-MS). A semi-quantitative automated competitive enzyme-linked immunosorbent assay (ELISA) methodology using Oral Fluid Micro-Plate Enzyme Immunoassays (Orasure Technologies, Inc.) was developed and validated. Applicability was proven by analysis of authentic head hair samples from drug users (n=103) and from opiate associated fatalities (n=21). The optimum cutoff values for the ELISA tests were 0.1 ng cocaine-equivalents/mg hair and 0.05 ng morphine-equivalents/mg hair using a 50 mg hair sample. Both ELISA tests had a sensitivity of 100%, the specificity was 66% for cocaine-equivalents and 42% for morphine-equivalents. The intraassay precision was 11% for the cocaine and 3% for the opiates ELISA, while interassay precision was 12% for the cocaine and 4% for the opiates ELISA test. The actual analyte concentrations in the hair samples were determined using GC-MS and were between 0.04 and 5.20 ng/mg for heroin (HER), between 0.04 and 30.01 ng/mg for 6-monoacetylmorphine (MAM), between 0.03 and 11.87 ng/mg for morphine (MOR), between 0.02 and 1.84 ng/mg for codeine (COD), between 0.02 and 2.48 ng/mg for acetylcodeine (AC), between 0.01 and 21.37 ng/mg for cocaine (COC), between 0.03 and 10.51 ng/mg for benzoylecgonine (BE) and between 0.05 and 1.26 ng/mg for cocaethylene (CE). The automated ELISA tests were proven to be valid screening procedures for the detection of cocaine and opiates in hair as confirmed by GC-MS. Screening methods provide rapid and inexpensive automated pre-test procedures to detect drugs in hair or other matrices. For forensic purposes screening therefore represents an ideal complement to routinely applied GC-MS procedures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号