首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 387 毫秒
1.
2.
GC法检测血液和尿液中甲基苯丙胺和咖啡因   总被引:1,自引:1,他引:0  
目的建立同时测定血、尿中甲基苯丙胺和咖啡因含量的方法。方法应用GC/NPD技术,以4-苯基丁胺为内标,直接碱化,用氯仿提取,三氟乙酸酐衍生化,8CB熔融石英毛细管柱(30m×0.25mm×0.25μm)分析。结果生物样品中甲基苯丙胺与咖啡因在0.012—7.5μg/mL浓度范围内线性关系良好,检测限(S/N=3)依次为1.2ng/mL,0.6ng/mL(血);1.6ng/mL,0.8ng/mL(尿)。苯丙胺在0.017—10.0μg/mL浓度范围内线性关系良好,检测限为1.6mg/mL(血),3.2ng/mL(尿)。所有样本回收率均大于85%。结论本方法准确、灵敏,适用于血、尿中甲基苯丙胺及其代谢物苯丙胺的三氟乙酸酐衍生化物和咖啡因的同时检测,为判定滥用毒品种类、追查毒品来源以及研究生物体内甲基苯丙胺和咖啡因的交互影响提供了检测手段。  相似文献   

3.
目的建立分子印迹固相萃取(MISPE)、GC/MS分析方法,用于血液中苯丙胺类毒品检测。方法 10mmol/L醋酸铵缓冲液(pH8.0)4倍稀释空白添加血液,1mL甲醇,1mL10mmol/L醋酸铵缓冲液(pH8.0)活化苯丙胺类分子印迹固相萃取柱;2×1mL去离子水、1mL60%的乙腈去离子水、1mL1%醋酸乙腈洗涤杂质;2×1mL1%甲酸/甲醇洗脱,洗脱液挥干定容,经GC/NPD、GC/MS分析检测。结果各种苯丙胺类毒品回收率均在90%以上,在20~5 000ng/mL浓度范围内线性关系良好,r2为0.995 7~0.998 9,LOQ在16~30ng/mL之间,LOD在8~15ng/mL之间。结论本方法回收率高,净化效果显著,稳定性好,杂质干扰少,可用于血液中低浓度苯丙胺类毒品的分析检测。  相似文献   

4.
Toxicological evaluation of postmortem samples collected from a pilot involved in a unique fatal civil aircraft accident is described in this paper. A one-occupant airplane was substantially damaged upon colliding with terrain in poor visibility. Remains of the pilot were found outside the aircraft. Pathological examination revealed multiple blunt force injuries and vascular congestion. The fluorescence polarization immunoassay disclosed 8.0 microg/mL amphetamines in urine. Gas chromatographic/mass spectrometric analyses determined the presence of methamphetamine (1.13 microg/mL in blood and 59.2 microg/mL in urine) and amphetamine (0.022 microg/mL in blood and 1.50 microg/mL in urine). Methamphetamine was distributed throughout the body, including the brain. The amount of methamphetamine in gastric contents was 575-fold higher than that of amphetamine. The (+)- and (-)-forms of methamphetamine were present in equal proportions in gastric contents. The methamphetamine concentration found in blood was in the range sufficient to produce toxic effects, causing performance impairment.  相似文献   

5.
A rapid and effective solid-phase extraction procedure using Bond Elute Certify bonded silica sorbent cartridges was adopted to extract amphetamine, methamphetamine, and 3,4-methylenedioxymethamphetamine (MDMA or Ecstasy) from urine samples. The extract was derivatized with trichloroacetic anhydride prior to gas chromatography/mass spectrometry (GC/MS) analysis with selected ion monitoring of the following ions: 190, 91, 188; 204, 91, 202; 162, 135, 202; 194, 123; and 211, 209 for the derivatized amphetamine, methamphetamine, MDMA, d5-amphetamine, and d9-methamphetamine, respectively. The first of the ions listed for each compound was used for quantitation. The compound d5-amphetamine was used as the internal standard for amphetamine, and d9-methamphetamine was used for methamphetamine and MDMA. Results showed a higher than 65% recovery and a reproducibility with less than a 5% coefficient of variation. When a sample size of 2 mL was used, the lowest detectable concentration was about 50 ng/mL, and a near-perfect fit can be obtained (within the 250 to 4000-ng/mL concentration range studied) using a second-order polynomial model.  相似文献   

6.
In New Zealand many children have been removed from clandestine laboratories following Police intervention. In the last few years it has become standard procedure that these children have hair samples taken and these samples are submitted to the laboratory for analysis. There are various mechanisms for the incorporation of drugs into hair. The hair follicle has a rich blood supply, so any drug that may be circulating in the blood can be incorporated into the growing hair. Another mechanism is via external contamination, such as spilling a drug on the hair or through exposure to fumes or vapours. Hair samples were analysed for methamphetamine and amphetamine. From the 52 cases analysed 38 (73%) were positive for methamphetamine (>0.1 ng/mg) and amphetamine was detected in 34 of these cases. In no case was amphetamine detected without methamphetamine. The hair washes (prior to extraction) were also analysed (quantified in 30 of the positive cases) and only 3 had a wash to hair ratio of >0.1 (all were <0.5), which may be indicative of a low level of external contamination. This low level of evidence of external contamination suggests that the children are exposed to methamphetamine and are incorporating it into the hair through the blood stream.  相似文献   

7.
A fast method was designed for the simultaneous determination of amphetamine (A), methamphetamine (MA), PMA, MDA, MDMA, MDEA and MBDB in urine. The drugs were analysed by LC (ESI)-MS/MS, after a simple liquid-liquid extraction in the presence of the deuterated analogues. Reverse phase separation on an Atlantis dC18 Intelligent Speed column was achieved in less than 4 min under gradient conditions, and the total run time was 8 min. The method was fully validated, including linearity (1-1000 ng/mL for A, MDMA, MDEA and MBDB; 2-1000 ng/mL for MDA and PMA; 1-200 ng/mL for MA; r2>0.99 for all compounds), recovery (>80%), within-day and between-day precision and accuracy (CV and MRE<12.7% for intermediate level and ULOQ, and <17.2% for LLOQ), limit of detection (0.2 ng/mL for MDMA, MDEA and MBDB; 0.5 ng/mL for A, MA and PMA; 1 ng/mL for MDA) and quantitation (1 ng/mL for A, MA, MDMA, MDEA and MBDB; 2 ng/mL for MDA and PMA) and relative ion intensities. No matrix effect was observed. The procedure proved to be sensitive, specific and rapid, and was applied to real forensic cases.  相似文献   

8.
目的研究甲基苯丙胺及其代谢物苯丙胺在家兔体内的毒物代谢动力学行为。方法GC/MS法测定家兔灌胃甲基苯丙胺后不同时间点血、尿中甲基苯丙胺和代谢物苯丙胺浓度,采用3P97程序进行房室模型拟合以及毒物代谢动力学参数计算。结果甲基苯丙胺和苯丙胺在家兔体内的毒物代谢动力学过程均呈一级动力学特征,符合二室开放模型。甲基苯丙胺在家兔体内Cm ax为1.457 mg/L±0.094 mg/L,Tm ax为1.557h±0.078h,t1/2 ka、t1/2α和t1/2β分别为0.384h±0.052h、1.614h±0.036h和3.007h±0.430h,CL为1.769 L/h/kg±0.114 L/h/kg。甲基苯丙胺的毒物代谢动力学方程为:C t=2.767 e-0.746 t+1.454 e-0.234 t+4.119 e-1.746 t。结论甲基苯丙胺在家兔体内吸收、消除和代谢都较快。建立的甲基苯丙胺毒物代谢动力学方程和参数可为甲基苯丙胺分析的合理取样、从血药浓度推断服毒时间以及甲基苯丙胺滥用的法医学鉴定提供理论依据。  相似文献   

9.
目的考察司来吉兰及其代谢物在尿液中的含量变化,并结合实际案例探讨手性分析区分甲基苯丙胺滥用与司来吉兰服用的可行性。方法采用CHIROBIOTICTM V2手性液相色谱柱对尿液样品进行手性分离和液相色谱-串联质谱(LC-MS/MS)法测定,并对司来吉兰服药志愿者尿样、疑服用司来吉兰的涉毒人员尿样进行甲基苯丙胺和苯丙胺的手性分析。结果服用5 mg司来吉兰后,尿液中司来吉兰的检出时限仅为7h。尿液中R(-)-甲基苯丙胺和R(-)-苯丙胺约在7h质量浓度最高,分别为0.86μg/m L和0.18μg/m L,并在80 h和168 h后无法检出。应用该方法成功分析了疑服用司来吉兰的涉毒人员尿液中甲基苯丙胺和苯丙胺的来源。结论甲基苯丙胺和苯丙胺的手性分析以及司来吉兰代谢物检测可区分甲基苯丙胺滥用与司来吉兰服用。  相似文献   

10.
A simple and sensitive method for the simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood was developed using a headspace-solid phase microextraction (SPME) and derivatization. A 0.5 g whole blood sample, 5 microl d(5)-methamphetamine (50 micrig/ml) as an internal standard, and 0.5 ml sodium hydroxide (1 M) were placed into a 12 ml vial, and sealed rapidly with a silicone septum and an aluminum cap. Immediately after the vial was heated to 70 degrees C in an aluminium block heater, the needle of the SPME device was inserted through the septum of the vial, and the extraction fiber was exposed in the headspace for 15 min. First, heptafluorobutyric anhydride was injected into the injection port of the GC-MS, and the compounds extracted by the fiber were then desorbed and derivatized simultaneously by exposing the fiber in the injection port. The calibration curves, using an internal standard method, demonstrated good linearity throughout the concentration range from 0.01 to 1.0 microg/g. The detection limits of this method were 5.0 ng/g for fenfluramine and methamphetamine, and 10 ng/g for amphetamine. No interferences were found, and the time for analysis was about 30 min for one sample. This method was applied to a suicide case in which the victim ingested fenfluramine. Fenfluramine was detected in the blood sample collected from the victim at the concentration of 7.7 microg/g.  相似文献   

11.
Two hundred and forty-seven serum samples which have been collected by police during roadside testing and have been found positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDE) were analyzed for gamma-hydroxybutyrate (GHB). Serum samples were spiked with deuterated GHB as internal standard and acetonitrile was added to achieve dilution and protein precipitation. Samples were analyzed with a LC-MS/MS system operated in the multiple reaction monitoring mode (MRM) using a TurboIonSpray source. Chromatographic separation was achieved using a Synergi Polar RP column applying a gradient elution with a runtime of 15 min. To differentiate between endogenous and exogenously administered GHB a cut-off concentration of 10 microg/mL was applied. Five samples exceeded this concentration and were found positive for GHB. These samples were only found positive for amphetamine but no other amphetamine derivatives were detected, while in three samples THC and in one sample cocaine, benzoylecgonine and ethanol were found.  相似文献   

12.
Cocaine and methamphetamine remain highly abused drugs in the United States due to their euphoric effects. This study examines classical stimulant casework, defined as cases positive for methamphetamine and/or cocaine, received by the Toxicology Laboratory and the Drug Analysis Laboratory at the Dallas County Southwestern Institute of Forensic Sciences from local law enforcement agencies and/or the Office of the Medical Examiner (OME) between January 1, 2017, and December 31, 2022. Methamphetamine positivity increased from 10.4% to 20.3% in the Toxicology Laboratory over the 6 years, whereas cocaine positivity remained relatively stable at approximately 17%. Similarly, in the Drug Analysis Laboratory, the methamphetamine positivity rate changed from 24.8% to 33.2%, whereas cocaine identification remained stable at approximately 20%. Blood concentrations of methamphetamine in OME cases ranged from 10.1–42,740.0 ng/mL while they were lower in DWI casework ranging from 10.2–2385.0 ng/mL. The blood concentration trends of cocaine were similar to methamphetamine, with OME casework ranging higher (10.0–24,501.0 ng/mL) than DWI casework (10.2–371.6 ng/mL). Polydrug use was evident for both methamphetamine and cocaine in postmortem cases, and the top three most frequently co-occurring drug/drug class were opioids/opiates, cannabinoids, and ethanol. The results from this study aid in the understanding of historical usage trends of cocaine and methamphetamine in Dallas County and how those trends have changed over time as newer stimulant drugs have emerged.  相似文献   

13.
Fentanyl is a potent synthetic opioid used as a general anesthetic and analgetic. Fatal outcome from intravenous misuse of transdermal fentanyl is rare, and there are few such reports in literature. Here we report two cases of fatal intravenous injection of the content from fentanyl patches. Both were male drug addicts, found dead within a one week interval in the same apartment. Post-mortem femoral blood was screened for amphetamines, cannabinoids, cocaine, and opioids with immunological methods (EMIT II) and further with headspace gas chromatography for alcohol and with liquid chromatography mass spectrometry (LC-MS) for different drugs, including fentanyl. Confirmatory analysis of fentanyl and morphine was performed by gas chromatography-mass spectrometry (GC-MS). In the first case, the toxicological analysis revealed fentanyl (2.7 ng/mL), morphine (31.4 ng/mL), and ethanol (1.1 g/L) in postmortem blood and amphetamine, cannabinoids, morphine, and ethanol (1.4 g/L) in postmortem urine. In the second case, the analysis revealed fentanyl (13.8 ng/mL), 7-aminoclonazepam (57.1 ng/mL), and sertralin (91.9 ng/mL) in postmortem blood and a small amount of ethanol (0.1 g/L) in postmortem urine. Police investigation revealed that both the deceased had bought the patches from the same source. The present cases demonstrate the possibility of intravenous misuse of transdermal patches and the risk of fatal outcome.  相似文献   

14.
An extraction and determination method of most important amphetamine derivatives in serum has been developed. The procedure comprises liquid-liquid extraction with tert-butyl methyl ether of the sample under basic conditions, centrifugation, formation of hydrochloric salts after the separation of organic phase, vacuum evaporation of the organic solvent at 60 degrees C, and trifluoroacetylation by on-line flash injection with MBTFA. GC analysis was performed by electron impact GC-MS in SIM mode. In this way satisfactory identification of 12 amphetamine derivatives could be obtained. Amphetamine, methamphetamine, MDA, MDMA and MDEA could be analyzed by using pentadeuterated analogs as internal standards. Low limits of detection 2.5-6.9 ng/mL could be reached. The assay was linear within the 5-100 ng/mL range with a regression coefficient greater than 0.999 for each compound. Our derivatization method is of low cost since only 1 microL of MBTFA is used for each flash trifluoroacetylation.  相似文献   

15.
A preliminary initial enzyme-linked immunosorbent assay (LUCIO-Direct ELISA kit) and a preliminary DRI enzyme immunoassay were evaluated for drug detection in head hair with respect to lowered cutoff values recommended in Germany for the control of abstinence in cases of re-granting of drivers' licences. Following drug classes were included: cannabinoids, opiates, cocaine like substances, amphetamine, methamphetamine (and methylenedioxyamphetamines), methadone, and benzodiazepines. 759 analyses were performed using LUCIO-Direct ELISA kits and 936 analyses using DRI enzyme immunoassay tests. Sample size for each drug group and immunoassay test reached from 74 to 178. The LUCIO-Direct ELISA kit revealed a sensitivity of 91% for amphetamine up to 98% for methadone (methamphetamine 92%, cocaine 94%, opiates 94%, benzodiazepines 96%) and values of specificity of 72% for methadone up to 89% for amphetamine and benzodiazepines. The test was not useful for a preliminary screening for tetrahydrocannabinol (sensitivity of 65%) in consideration of a suggested cutoff of 0.02 ng/mg. The DRI enzyme immunoassay test was only useful for morphine and cocaine testing at low recommended new cutoff values (0.1 ng/mg) revealing sensitivities of 94% and 99%, respectively.  相似文献   

16.
We encountered three methamphetamine (MA) body packers presenting simultaneously, one of whom died. Three Nigerian men (39, 35, and 37 years old) who attempted to smuggle were found to contain 35 (498 g), 21 (292 g), and 5 packages (73 g) of methamphetamine hydrochloride (MA-HCl) in their stomachs, respectively. Packages were wrapped with plastic film and Scotch tape. The 39-year-old man died with acute poisoning from c. 20 g of MA-HCl that had leaked from the packages into the stomach. His plasma MA concentration was 8.6 microg/mL when he was hospitalized (17 h before his death). Autopsy findings showed extreme pulmonary congestion and edema as well as moderate hepatic edema and several petechiae. Quantitative analysis was performed by gas chromatography/mass spectrometry. Extremely high concentrations of MA and its metabolite amphetamine (AP) were found in cardiac blood (63.5 microg/mL and 1.2 microg/mL), urine (4,518 microg/mL and 72.4 microg/mL), gastric contents (8,490 microg/mL and 16.9 microg/mL), and in all other autopsy samples. These high concentrations confirmed that the cause of death was acute MA poisoning. Furthermore, impurity-profiling analysis of the seized MA revealed that the MA smuggled by the three suspects originated from the same batch.  相似文献   

17.
We describe a case of massive hemorrhage in the cerebral ventricles, probably caused by methamphetamine abuse. A 44-year-old male was found dead in a prone position in a hotel room. Old and new injection marks were observed in his right cubital fossa. Petechiae were observed on the conjunctiva of his right eye, laryngeal mucosa, epicardium and under the capsule of the liver (to a slight or moderate degree). The brain, weighing 1.67 kg, was heavily edematous; the lateral and fourth ventricles were filled with hematomas. Subarachnoid, intracerebral hemorrhages were not observed. Cerebral vascular abnormalities were not evident. There were no remarkable changes in other organs, other than congestion. Gas chromatographic-mass spectrometric analysis of the urine disclosed the presence of methamphetamine and amphetamine. The concentration of methamphetamine within the femoral venous blood and intraventricular hematoma was 0.347 microg/ml and 0.189 microg/g, respectively. Amphetamine was not detected in either sample. Urine contained 3.15 microg/ml methamphetamine and 0.063 microg/ml amphetamine. These results indicate that intraventricular hemorrhage might have occurred shortly after intravenous self-administration of methamphetamine. Cerebral arterial spasm and hypertension resulting from the administration of methamphetamine might have resulted in intraventricular hemorrhage.  相似文献   

18.
Determination of methamphetamine and amphetamine in hair was performed by gas chromatography/mass spectrometry using stable isotope-labeled internal standards, 2-methylamino-1-phenylpropane-2,3,3,3-d4 and 2-amino-1-phenylpropane-2,3,3,3-d4. Extraction of hair with methanol/5M hydrochloric acid (20:1) using ultrasonication was chosen as the standard method. The calibration curves for amphetamines in the hair were linear from 1 to 100 ng/mg (r greater than 0.99). The detection limit was 0.5 ng/mg at the 95% confidence level. The coefficients of variation (CV) (n = 8) of analysis using the spiked hair with methamphetamine were from 0.7 to 6%. The CV (n = 8) of analysis of the methamphetamine abuser's hair was 17.5%. Sectional analysis of monkey and human hair after methamphetamine ingestion suggested a good correlation between the duration of drug use and drug distribution in the hair.  相似文献   

19.
目的建立SPME-GC-MS快速检测吸毒人员尿液中的甲基苯丙胺的方法。方法以SPME法提取尿液中的甲基苯丙胺,以1-萘胺作内标,用GC-MS法检测。结果在2~2000ng/mL的范围内呈线性关系(r=0.9985,n=7),甲基苯丙胺的检测限为0.5ng/mL(信噪比3),在低、中、高(200、500、1000ng/mL)浓度的平均相对回收率为102.6%、98.5%、93.2%,日内及日间RSD分别小于8.1%、7.2%。结论用此方法检测尿液中的甲基苯丙胺,灵敏度高,简单快速,易操作,适用于吸毒人员的快速定性定量检测。  相似文献   

20.
Qualitative and quantitative analysis of methamphetamine and amphetamine in biologic materials was carried out by gas chromatography/mass spectrometry. A deuterium-labeled methamphetamine was employed as an internal standard with a detection limit of 50 pg and absolute stability and reproducibility. Blood was found to be the best material for estimation of the toxicity of the stimulant drug. It can be replaced by muscle which contains methamphetamine concentrations close to those of blood. The authors' classification of the toxic blood levels of methamphetamine from therapeutic to fatal doses was confirmed by additional data obtained from new case studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号