首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
STR profiling using hard tissues obtained from a severely decomposed body is sometimes a laborious work. There is now on a market a new DNA extraction kit, PrepFiler™ Forensic DNA Extraction Kit (AppliedBiosystems), and we tested it for missing persons. Postmortem intervals ranged from weeks to several years. Fifteen bone fragments and eleven nails were used in this report. Genomic DNA was quantified by QuantiFiler® DUO Quantification Kit (AppliedBiosystems), and STRs were analyzed using AmpFlSTR® Identifiler® PCR Amplification Kit (AppliedBiosystems). The profiling of 16 STR loci was successful in all nail samples. However, STR profiling was successful in only 6 of 15 bone materials. Nine cases failed to analyze STR polymorphisms using another DNA extraction kit, the QIAamp DNA Mini Kit (QIAGEN). For bone samples, it seems that STR profiling depends on the quality of samples.  相似文献   

2.
Analysis of forensic samples to evaluate the rate of success for molecular markers: autosomal STRs, Y chromosome, and mitochondrial DNA. Since 2006 to date a total of 390 forensic samples were analyzed: bones, teeth, hairs, swabs, stains and paraffin embedded tissue. Bones and teeth, were pulverized in a Freezer Mill, extracted by chloroform/phenol/isoamyl alcohol method, and then purified with Centricon 100 columns. DNA from paraffin was extracted with QIAmp DNA Mini kit (QIAGEN). Mitochondrial DNA Control Region sequences were determined for regions HV1/HV2. Sequencing was performed using the BigDye® Terminator v 1.1 Kit and analyzed in ABIPRISM® 3100 Genetic Analyzer (AB). STRs were amplified using Amp FlSTR Identifiler®, Minifiler® and YFiler® Kit (AB) and analyzed in ABI PRISM® 3100 Genetic Analyzer and ABI PRISM® 3130xl Genetic Analyzer (AB). Among forensic samples, bones and teeth analyzed for autosomal STRs, we obtained successful results in all of them. Incomplete typing are represented by loci of higher molecular weight, which demonstrates the poor quality of the sample due to its state of degradation and obtained better results using mini STRs. Successful results in sequencing for mitochondrial HV1 region for all samples analyzed, but in few hair samples we obtained mixed sequences and that represented important difficulties for the analysis. Age of samples and conservation are factors related which affect DNA viability. Autosomal STRs solved all the samples analyzed in our study, but Y chromosome analysis and mitochondrial DNA sequencing are also important and necessary markers in some forensic cases.  相似文献   

3.
Manual Chelex®-100 and organic extractions (phenol/chloroform) are used as routine methods at the Swedish National Laboratory of Forensic Science, SKL. The aim of this study was to find an automated DNA purification system to replace the organic method. The following methods were evaluated and compared to each other and to the organic method used routinely; BioRobot® EZ1 with EZ1 DNA Investigator Kit and Card (Qiagen), iPrep™ Purification Instrument with iPrep™ ChargeSwitch® Forensic Kit and Card (Invitrogen), Magnatrix™ 1200 Workstation with the Magnatrix™ gDNA Blood Kit Forensic and two different protocols; Forensic protocol A and B (Magnetic Biosolutions). Blood on fats, cotton swabs, moist snuff, paper towels and leather, post-mortem blood and muscle tissue were extracted with the different methods. DNA concentration and quality of the electropherograms were examined. Individual comparisons between the four extraction methods showed that iPrep™ and Magnatrix™ 1200 gave significantly lower mean quantities compared to BioRobot® EZ1 and the organic extraction method (p < 0.05). There were no significant differences between the latter two. BioRobot® EZ1 generated the best results and is in the process of being validated for routine analysis at SKL.  相似文献   

4.
Differential extraction is an efficient method to separate sperm cells from epithelial cells. A manual Chelex®-100 based method is used at the Swedish National Laboratory of Forensic Science, SKL. The Differex™ System (Promega) uses a Proteinase K digestion of epithelial cells followed by centrifugation and phase separation. The sperm- and epithelial fractions are further purified with DNA IQ™ System (Promega) or with phenol/chloroform. The Differex™ System in combination with DNA IQ™ System were evaluated and compared to the Chelex®-100 method used routinely. After modifications, the Differex™ System gave comparable results to the Chelex®-100 method. The modifications included additional Proteinase K and DTT, longer incubation time and additional steps when removing the solid support from the Digestion Solution. In the Chelex®-100 based method microscopic examination is done on the sperm pellet in a total volume of 50 μl. It was not possible to do a microscopic examination in less than 100 μl using the Differex™ System. Additionally the sperms were in clusters of epithelial cell debris. Microscopic examination is an important part of the differential extraction at SKL. Therefore, the Differex™ System will not be implemented at our laboratory.  相似文献   

5.
In forensic science, fingerprints are a common source of evidentiary information. However, latent examination is not always successful and trace human DNA cannot always be obtained. Thus, examining the fingerprint microbiome may offer a suitable alternative to more traditional methods of forensic identification. The Zymo Research ZR Bacterial/Fungal DNA MicroPrep™ Kit, Qiagen QIAmp® DNA Mini Kit, Promega Wizard® Genomic DNA Purification Kit, and the MPBio FastDNA® Spin Kit were compared for their ability to yield a sufficient amount of bacterial DNA for next-generation sequencing in order to obtain a microbiome profile. Prints were deposited onto slides, allowed to sit for up to 1 month, and total DNA isolated and quantified using each kit. The kit from Zymo Research yielded the most concentrated DNA sample (0.0084 ng/µL) in the least amount of time as compared to other kits examined. Although this amount of DNA was far below the recommended DNA concentration threshold recommended for next-generation sequencing, a microbiome profile was successfully obtained. As interest in using the microbiome of an individual as a forensic tool continues to increase, there is the possibility that the microbiome of a fingerprint could complement traditional human DNA profiling in the future. This study provides evidence that trace amounts of bacterial DNA from fingerprints is quantifiable and sufficient for microbiome analysis.  相似文献   

6.
Chen RH  Song Q  Xu QW  Dong Y 《法医学杂志》2007,23(4):302-303
目的研究吸附性载体上微量血痕的DNA提取及其检验。方法用Chelex-100法、QIAamp MiniKit、及QIAamp Mini Kit改良法提取吸附性载体上微量血痕中的DNA,进行PCR扩增及STR检验。结果采用Chelex-100法及QIAamp Mini Kit的分型成功率很低;采用QIAamp Mini Kit的改良法能较好的得到分型图谱。结论采用QIAamp Mini Kit的改良法能较好的提取吸附性载体上微量血痕的模板DNA。  相似文献   

7.
It is proposed that a DNA stabilizing solution (DNA Genotek Inc.) designed to preserve DNA in saliva samples at room temperature can be extrapolated to the storage of swab heads. The aim of this study was to evaluate the effectiveness of the solution for the preservation of reference swabs (buccal) and trace samples (facial swabs). To this end, the solution was used during a twin-site DNA transfer project assessing background levels of carer DNA present in children. Tubes containing 400 μl of solution were used to store and transport swab heads. At the laboratory, samples were extracted using the QIAamp DNA Mini Kit (Qiagen), quantified using the Quantifiler Duo Kit and profiled using the AmpF?STR® SGM Plus® PCR Amplification Kit (both Applied Biosystems). Twenty-eight PCR cycles were applied to all samples. Thirty-four cycles or a longer electrophoresis injection time was applied to trace samples where necessary. All Reference swabs produced high quantities of DNA and full DNA profiles after 28 cycles. Profile morphology indicated good quality DNA with no degradation. Of the trace samples, sufficient profiles were achieved to study the transfer of carer DNA making the solution fit for continued use in this project. DNA stabilizing solution enables the storage and transportation of swabs without freezing. This is convenient, reduces transportation costs and enables instant analysis of samples upon arrival at the laboratory. This is a useful alternative for a multi-site research project as well as a reliable storage tool for use in remote areas.  相似文献   

8.
FTA Cards (GE Healthcare) have been used for more than 4 years in Denmark for the collection of buccal cells as reference samples in crime cases. Semi-automated protocols for STR typing of DNA on punches of FTA Cards are routinely used. In average, full STR profiles were generated from approximately 95% of the FTA Cards with a standard punching protocol, while partial or no STR profile were obtained from 5% of the samples. Here, the Qiagen BioRobot® EZ1 Workstation (Qiagen) and the EZ1 DNA Investigator Kit (Qiagen) was used to extract DNA from 29 FTA Cards from which a complete STR profile was not generated with the standard punching protocol. All 29 samples were successfully typed with the AmpF?STR® Identifiler™ PCR Amplification Kit (Applied Biosystems) and with the SNPforID 49plex SNP assay. The lowest amount of DNA that resulted in complete STR and SNP profiles was 80 pg. The STR and SNP profiles were identical to those generated from another sample collected from each of the 29 individuals.  相似文献   

9.
With large number of criminal acts, such as rape and murder, identification of the perpetrator is very difficult to determine. The cause is the lack of sufficient quantity of biological traces provided as material evidence, or the biological material is decomposed and no result can be obtained by using other identification methods. Thus the case remains unsolved. The purpose of this research is to establish a reliable method for detecting semen presence in rape cases and to get DNA profile from the perpetrator of a crime. Vaginal swabs were taken using cotton swabs during gynecological examination or autopsy in 21 cases. The chemical detection of semen presence was performed using Phospathesmo Kits. The DNA extraction was performed using QIAAamp® DNA Mini Kit. The amplification was performed using AmpFistrIdentifiler Kit and AmpFistrYfiler Kit. The electrophoresis was performed using 310 ABI squenator. Results indicate that DNA profile was obtained in 4 cases where chemical tests did not prove semen presence using Phospathesmo Kits. In one case, neither semen presence was chemically proven nor DNA profile was obtained for autosomal STRs, but a profile for Y-STRs was obtained. Our analyses indicate that when the victim's body is examined within the first few hours or the first day, a genetic profile of the perpetrator of the criminal act is obtained. Besides using autosomal STRs, we recommend Y-STRs to be used in all rape cases, too, thus separating the male from female profile, and also the male kinship relatedness in cases of incest could be followed, the rape performed by several blood-related men or similar.  相似文献   

10.
Calcified tissues, such as bone and tooth, and some other sample types, such as those containing adhesive, present a challenge to standard extraction protocols. We have developed a lysis reagent, BTA™ lysis buffer, which is designed for use with PrepFiler™ Kit reagents. The BTA™ lysis buffer disrupts calcified tissue matrices and achieves effective extraction of DNA from pulverized bone and tooth samples. In addition, the BTA™ lysis buffer mildly but efficiently extracts DNA from challenging substrates like tape, chewing gum, and cigarette butts and, as with bone and tooth, DNA from these lysates is purified using established PrepFiler™ reagent extraction protocols.We successfully extracted DNA from powdered human bone samples, chewed gum and smoked cigarettes using BTA™ lysis buffer. Extraction yields for bone, gum and cigarette samples tested were consistent and reproducible. This extraction method efficiently removed potential PCR inhibitors from all samples tested, and CT values for the internal PCR control of Quantifiler® Human DNA Quantification Kit were consistent and within the normal range. The DNA extracted from these samples also provided conclusive profiles that were free of PCR artifacts when amplified using the AmpF?STR® Identifiler® PCR Amplification Kit. The protocol is easily adapted for automation.  相似文献   

11.
We describe the developmental validation study performed on the PowerPlex® ESX 16 (European Standard Extended 16) and the PowerPlex® ESX 17 Systems, part of a suite of four new DNA profiling kits developed by Promega in response to the ENFSI and EDNAP groups’ call for new STR multiplexes for Europe. The PowerPlex® ESX 16 System combines the 11 loci compatible with the UK National DNA Database, contained within the AmpFlSTR® SGM Plus® PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to incorporate these five new loci as mini- and midi-STRs while maintaining the loci found in the AmpFlSTR® SGM Plus® kit as standard size. The PowerPlex® ESX 17 System amplifies the same loci as the PowerPlex® ESX 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR® SGM Plus® kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex® ESX 16 and ESX 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5 pg of a fully heterozygous single source DNA template. In mixture analysis, a range of 52-95% of unique minor contributor alleles was observed at 19:1 mixture ratios where only 25 pg of the minor component was present. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of information obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors.  相似文献   

12.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

13.
In sexual assault cases DNA profiling of spermatozoa can be of critical importance. Most methods use differential extraction of the spermatozoa to separate it from the female component. Here we have compared two commercially available differential extraction methods, the QIAamp® DNA mini kit (Qiagen) and Differex™ with the DNA IQ® System (Promega). Simulated postcoital samples were prepared using buccal cells from a female donor and spermatozoa from three male donors. A dilution series ranging from neat semen to a 1:1500 dilution (semen:dH2O) was prepared and mixed with an equal volume of saliva from a female donor. Extraction efficiency was assessed using DNA concentration measured with NanoDrop 2000 and Quantifiler® Human DNA Quantification Kit and the profile count of full, partial and mixed DNA profiles generated using SGM Plus and PowerPlex® ESI 17. Statistical analysis was carried out using Randomisation in R, which is a robust model making no assumption of the distribution of data. Based on the amount of DNA extracted and the types of profiles no significant difference in the performance of the two extraction kits was seen. However, the processing time taken with the Differex™ System was about half than that of the QIAamp® DNA mini kit and involved fewer liquid transfers.  相似文献   

14.
Within the initial step of the forensic DNA analysis process, the DNA extraction efficiency and especially the removal of potential PCR inhibitors is crucial for subsequent steps, e.g. quantification by real-time PCR and amplification of short tandem repeats (STRs). The protocol of the PrepFiler™ Forensic DNA Extraction Kit was optimized for the application on a Tecan liquid handling workstation Freedom EVO® 150. This modified application of the PrepFiler™ technology was compared with respect to DNA yield, sensitivity and the ability to remove potential PCR inhibitors to an established routine method working on the same liquid handling workstation based on ChargeSwitch® Technology (CST) from Invitrogen.  相似文献   

15.
We have implemented and validated automated methods for DNA extraction and PCR setup developed for a Tecan Freedom EVO® liquid handler mounted with a Te-MagS™ magnetic separation device. The DNA was extracted using the Qiagen MagAttract® DNA Mini M48 kit. The DNA was amplified using AmpF?STR® Identifiler®, Y-filer® (Applied Biosystems), GenePrint® FFFL and PowerPlex® Y (Promega). The methods were validated for fresh whole blood and blood from deceased according to EN/ISO 17025.  相似文献   

16.
The transfer of DNA from hands to objects by holding or touching has been examined in the past. The main purpose of this study was to examine the variation in the amount of DNA transferred from hands to glass, fabric and wood. The study involved 300 volunteers (100 for glass, 100 for fabric and 100 for wood) 50% of which were male and 50% female. The volunteers held the material for 60 s. The DNA was recovered from the objects using a minitape lift, quantified using the Quantifiler kit assay, extracted using a ‘Qiagen® QIAamp DNA mini kit’ and amplified using the AmpFlSTR® SGM Plus™ Amplification Kit at 28 cycles. The results show that using ANOVA there was a significant difference (F = 8.2, p < 0.05) between the three object types in the amount of DNA recovered. In terms of DNA transfer and recovery, wood gave the best yield, followed by fabric and then glass. The likelihood of success of obtaining a profile indicative of the holder was approximately 9% for glass samples, 23% for fabric and 36% for wood. There was no significant difference between the amount of DNA transferred by male or female volunteers. In this study good shedder status, as defined by obtaining useful profiles of 6 or more alleles, is estimated at approximately 22% of the population. The phenomenon of secondary transfer was observed when mixed DNA profiles were obtained but the incidence was low at approximately 10% of the total number of samples. DNA profiles corresponding to more than one person were found on objects which had been touched by only one volunteer. Although secondary transfer is possible the profiles obtained from touched objects are more likely to be as a result of primary transfer rather than a secondary source.  相似文献   

17.
This study investigated the various factors affecting DNA profiling from DNA recovered from fingerprints deposited on paper before and after fingerprint enhancement treatments. The DNeasy® plant mini kit (QIAGEN®) was found to improve DNA recovery from paper by over 150% compared with the QIAamp® mini kit. A significant decrease in the amount of DNA recovered was observed following treatment with DFO and/or Ninhydrin. This decrease in yield did not have a comparably significant effect on the quality of the SGM Plus™ profiles. Furthermore, this study found that whilst certain paper types, such as newspaper, magazine and filter paper allowed for the good recovery of DNA, common office paper and white card, strongly interfered with the recovery of DNA resulting in poor quality profiles.  相似文献   

18.
The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR® Profiler Plus® to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4 h to 26 min. No modification to the commercial AmpFlSTR® Profiler Plus® primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n − 4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR® Profiler Plus® primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases.  相似文献   

19.
All forensic laboratories routinely use commercial kits and softwares for automated typing; in rare cases genotyping misinterpretations or mislabellings occur. This study refers to the investigation on a D2S1338 off-ladder allele mislabelling observed in DNA profile of murdered woman.The Identifiler® revealed heterozygosity in the range of D16S539, with a presumptive microvariant allele “14.2”, based on assigned size, while PowerPlex®16 resulted in a homozygosity of allele “11”. Singleplex amplification of D16S539 locus confirmed homozigosity. D2S1338 locus, the closest to D16S1338 in Identifiler®, genotyped as homozigote “19”, was singleplex amplified. The off-ladder peak was gel-isolated, sequenced and designed as a rare “11” allele variant [(TGCC)6(TTCC)5]. Genotype was finally designed as D16S539 “11,11” and D2S1338 “11,19”.To avoid genotyping misinterpretations or mislabelling, ambiguous genotypes should be established by two commercial kits at least. Furthermore, off ladder alleles as well as allele microvariants should be assigned by direct sequencing. This issue should be considered in Criminal DNA database requirements, that is still under debate in Italy.  相似文献   

20.
The recovery of DNA data from old skeletal remains is often difficult due to degraded and very low yield of extracted DNA and the presence of PCR inhibitors. Herein, we compared several silica-based DNA extraction methods from artificially degraded DNA, DNA with PCR inhibitors and DNA from old skeletal remains using quantitative real-time PCR. We present a modified large-scale silica-based extraction combined with complete demineralization, that enables maximum DNA recovery and efficient elimination of PCR inhibitors. This is performed with high concentration of EDTA solution for demineralization of bone powder followed by QIAamp® spin columns and buffers from the QIAquick® PCR purification kit. We have successfully used this modified technique to perform STR analysis for 55-year-old skeletal remains. The results of this study will contribute to solve the forensic cases dealing with skeletal remains.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号