首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In forensic DNA analysis, the samples recovered from the crime scene are often highly degraded leading to poor PCR amplification of the larger sized STR loci. To avoid this problem, we have developed STR markers with redesigned primer sequences called "Miniplexes" to produce smaller amplicons. To assess the effectiveness of these kits, we have tested these primer sets with enzymatically degraded DNA and compared the amplifications to a commercial kit. We also conducted sensitivity and peak balance studies of three Miniplex sets. Lastly, we report a case study on two human skeletal remain samples collected from different environmental conditions. In both types of degraded DNA, the Miniplex primer sets were capable of producing more complete profiles when compared to the larger sized amplicons from the commercial kit. Correct genotypes were obtained at template concentrations as low as 31 pg/25 microL. Overall, our data confirm that our redesigned primers can increase the probability of obtaining a usable profile in situations where standard kits fail.  相似文献   

2.
Two multiplex polymerase chain reaction (PCR) systems (Midiplex and Miniplex) were developed for the amplification of the mitochondrial DNA (mtDNA) control region, and the efficiencies of the multiplexes for amplifying degraded DNA were validated using old skeletal remains. The Midiplex system consisted of two multiplex PCRs to amplify six overlapping amplicons ranging in length from 227 to 267 bp. The Miniplex system consisted of three multiplex PCRs to amplify 10 overlapping short amplicons ranging in length from 142 to 185 bp. Most mtDNA control region sequences of several 60‐year‐old and 400–500‐year‐old skeletal remains were successfully obtained using both PCR systems and consistent with those previously obtained by monoplex amplification. The multiplex system consisting of smaller amplicons is effective for mtDNA sequence analyses of ancient and forensic degraded samples, saving time, cost, and the amount of DNA sample consumed during analysis.  相似文献   

3.
Since the beginning of our work in 2003 our laboratory has focused exclusively on STR DNA from bone, a powerful tool in missing person cases. In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, recovered from water, degraded, and/or contain inhibitory substances. To address these challenges, this study has evaluated the performance of relatively new STR kits Investigator® 24plex QS kit (Qiagen) and GlobalFiler™ PCR Amplification kit (Thermo Fisher Scientific) by comparing it with current uses of the AmpFLSTR® Identifiler® Plus kit (Applied Biosystems) to obtain genetic information from skeletal remains. We analyzed 20 bone samples of skeletal remains from routine casework submitted for body identifications by law enforcement corresponding using Investigator® 24plex QS kit and GlobalFiler™ PCR Amplification kit, previously analysed AmpFLSTR® Identifiler® Plus kit (Thermo Fisher Scientific). The data indicates that the STR profiles obtained using the GlobalFiler™ and Investigator® 24plex QS kit for analysis of skeletal remains has shown results in an increased number of reportable genetic loci, and provide greater power of discrimination in comparison to the Identifiler® Plus Kit. Advanced extraction and purification techniques, together with more sensitive and robust new amplification kits allowed us to overcome the challenges associated with processing compromised skeletal remains and ultimately obtain full STR DNA profiles in 99% of the bones.  相似文献   

4.
This paper describes a developmental validation study of three Miniplex sets covering 12 of the 13 CODIS loci. As these new sets will be used for the analysis of degraded and low level DNA, the validation studies were performed using 100-125 pg of DNA, the lowest input level at which peak balance, peak intensity, and allele consistency were stable. To demonstrate the applicability of the Miniplex sets to forensic casework, these validation studies were completed in accordance with the Scientific Working Group on DNA Analysis Methods (SWGDAM). A range of tests were performed including studies of concordance with standard multiplex kits, sensitivity and reproducibility, and PCR amplification conditions. Additionally, studies of mixtures, nonhuman and environmentally degraded DNA, and simulated forensic samples were performed. Our results demonstrate that Miniplex STR amplification procedures are a robust and sensitive tool for the analysis of degraded DNA.  相似文献   

5.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

6.
The analysis of degraded DNA is one of the biggest challenges in forensic casework. SNPs, which can be amplified using small amplicons, have previously been successfully applied to the profiling of forensic evidence that could not be analyzed using conventional STRs. Here we selected the 52 SNPforID SNP markers, with amplicons that ranged in size from 59 bp to 115 bp, and used them to profile a range of casework samples from Malaysia. DNA degradation is a common problem in Malaysia due to the high temperatures and humidity. To carry out the study we modified the 52 SNPforID markers into four 13-plex SNaPshot assays to enable easier interpretation of profiles on the ABI PRISM® 310 and 3500.Fifty-one crime samples comprising bloodstains on cloth, swabs, and a mat and 2 swabs of trace DNA from 10 crime scenes in Malaysia were profiled after DNA extraction using a phenol–chloroform method. The samples were also subjected to STR analysis using the Powerplex® 16 system (Promega), which resulted in only 17 full profiles and 9 partial profiles; using SNPs, 36 full profiles and 5 partial profiles could be generated.  相似文献   

7.
Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons.In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled in two PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818.After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin's fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.  相似文献   

8.
Nuclear DNA was extracted from human telogen hairs from 60 individuals. Six to nine hairs from each individual were individually extracted. The amount of DNA recovered from each individual varied greatly, and most samples yielded a quantity of 550 pg or less per hair. A selective extraction buffer was used to remove epithelial cell DNA and the amount of exogenous DNA was determined. DNA was also quantified by real time PCR using three different sized amplicons targeting an Alu sequence. The results were used to determine the state of degradation of the extracted DNA. Different quantities of sample (<100 pg, 100-500 pg, >500 pg) were amplified with the Miniplex kits to determine the minimum DNA template required for successful amplification. DNA recovered from hair showed degradation; however, partial profiles were obtained for those samples containing at least 60 pg using MiniSTRs.  相似文献   

9.
Personal products, such as toothbrushes, have been used as both known reference and evidentiary samples for forensic DNA analysis. This study examined the viability of a broad selection of cosmetic applicators for use as targets for human DNA extraction and short tandem repeat (STR) analysis using standard polymerase chain reaction (PCR) conditions. Applicator types included eyeliner smudgers, pencils and crayons, eye shadow sponges, mascara wands, concealer wands, face makeup sponges, pads and brushes, lipsticks and balms, and lip gloss wands. The quantity and quality of DNA extracted from each type of applicator were examined by assessing the number of loci successfully amplified and the peak balance of the heterozygous alleles in each full STR profile. While degraded DNA, stochastic amplification, and PCR inhibition were observed for some items, full STR profiles were developed for 14 of 76 applicators. The face makeup sponge applicators yielded the highest proportional number of full STR profiles (4/7).  相似文献   

10.
An alternate method for quantitation of human genomic DNA is presented. Quantitative template amplification technology (abbreviated "Q-TAT") estimates the quantity of human DNA present in an extract by comparing fluorescence in X and Y amplicons produced from unknowns with fluorescence in a standard curve amplified from known quantities of reference DNA. Q-TAT utilizes PCR and electrophoresis with fluorescent detection/quantitation, precluding the need for new instrumentation, methodology, or quality assurance associated with slot-blot or real-time PCR. In a comparison study incorporating shared samples, Q-TAT was found to be more sensitive than widely used slot-blot methods but somewhat less sensitive than real-time PCR. Among samples containing DNA concentrations ranging from 100 pg/microL to 2-4 ng/microL, Q-TAT produced DNA concentration estimates that agreed reasonably well with either Quantiblot or real-time PCR. Q-TAT was reproducible with a typical coincidence of variation of about 35%. Quantitation of human DNA in this study involved summing fluorescence in X and Y amplicons in unknowns and quantitation standards. However, analyzing fluorescence in X and Y amplicons individually could allow estimates of male and female DNA present in mixtures to be made. Moreover, since X and Y amplicons exhibit sizes of 210 and 216 bp, respectively, the integrity as well as the concentration of the genomic DNA template can be assessed. Q-TAT represents an alternate method useful for the quantitation of human genomic DNA prior to amplification of STR loci used for identity testing purposes. The method uses existing equipment and procedures in conjunction with a well-characterized DNA standard to produce concentration estimates for unknowns that reliably produce STR profiles suitable for analysis.  相似文献   

11.
Recently, there has been much debate about what kinds of genetic markers should be implemented as new core loci that constitute national DNA databases. The choices lie between conventional STRs, ranging in size from 100 to 450 bp; mini-STRs, with amplicon sizes less than 200 bp; and single nucleotide polymorphisms (SNPs). There is general agreement by the European DNA Profiling Group (EDNAP) and the European Network of Forensic Science Institutes (ENFSI) that the reason to implement new markers is to increase the chance of amplifying highly degraded DNA rather than to increase the discriminating power of the current techniques. A collaborative study between nine European and US laboratories was organised under the auspices of EDNAP. Each laboratory was supplied with a SNP multiplex kit (Foren-SNPs) provided by the Forensic Science Service, two mini-STR kits provided by the National Institute of Standards and Technology (NIST) and a set of degraded DNA stains (blood and saliva). Laboratories tested all three multiplex kits, along with their own existing DNA profiling technique, on the same sets of degraded samples. Results were collated and analysed and, in general, mini-STR systems were shown to be the most effective. Accordingly, the EDNAP and ENFSI working groups have recommended that existing STR loci are reengineered to provide smaller amplicons, and the adoption of three new European core loci has been agreed.  相似文献   

12.
Abstract: The identification of missing casualties of the Korean War (1950–1953) has been performed using mitochondrial DNA (mtDNA) profiles, but recent advances in DNA extraction techniques and approaches using smaller amplicons have significantly increased the possibility of obtaining DNA profiles from highly degraded skeletal remains. Therefore, 21 skeletal remains of Korean War victims and 24 samples from biological relatives of the supposed victims were selected based on circumstantial evidence and/or mtDNA‐matching results and were analyzed to confirm the alleged relationship. Cumulative likelihood ratios were obtained from autosomal short tandem repeat, Y‐chromosomal STR, and mtDNA‐genotyping results, and mainly confirmed the alleged relationship with values over 105. The present analysis emphasizes the value of mini‐ and Y‐STR systems as well as an efficient DNA extraction method in DNA testing for the identification of old skeletal remains.  相似文献   

13.
Abstract: We have developed a concept to enable the analyzing of degraded stains with limited DNA template quantity. Therefore we have constructed a short tandem repeat (STR) multiplex including the German DNA database systems (Q8). The amplicon lengths are smaller than 280 bp. For the validation of Q8 over 50 degraded samples were investigated. Amplifications were performed with “low copy number” PCR, the number of PCR cycles was increased to 33 and the reaction volume was decreased to 12.5 μL. Compared with the MPX2 and Nonaplex kit, the average success rate was increased using the Q8 kit by approximately 20% and 30%, respectively. The efficiency of a sensitive STR multiplex with reduced amplicon lengths was confirmed in comparing the success rates of Q8 for typing degraded samples and samples with limited amount of DNA template while partial profiles were observed with the majority of the samples using commercially available kits.  相似文献   

14.
Characterization of new miniSTR loci to aid analysis of degraded DNA   总被引:17,自引:0,他引:17  
A number of studies have demonstrated that successful analysis of degraded DNA specimens from mass disasters or forensic evidence improves with smaller sized polymerase chain reaction (PCR) products. We have scanned the literature for new STR loci, unlinked from the CODIS markers, which can generate amplicons less than 125 bp in size and would therefore be helpful in testing degraded DNA samples. New PCR primers were designed and tested for the STR loci D1S1677, D2S441, D4S2364, D10S1248, D14S1434, and D22S1045, arranged into two miniSTR triplexes. All loci show a moderate degree of polymorphism among 474 U.S. population samples tested and were reliable and sensitive to at least 100 pg of DNA template under controlled laboratory conditions and pristine DNA samples. The utility of these new loci were confirmed in comparing the success of the miniSTR assays for typing degraded bone samples while partial profiles were observed with the majority of the samples using a commercial STR kit.  相似文献   

15.
New multiplex PCR sets of commonly used short tandem repeat (STR) markers have been developed to produce PCR products that are reduced in size when compared to standard commercial STR kits. The reduction in size of these amplicons can facilitate the examination and analysis of degraded DNA evidence by improving amplification efficiency. This "miniSTR" approach will permit current forensic practitioners to use STR markers and instrumentation already present in their laboratories and to generate genotyping data that is directly comparable to reference samples and searchable through the FBI's Combined DNA Index System (CODIS) databases. This paper discusses the development of these new primer sets and presents some initial results in the analysis of degraded and aged DNA samples. A method for removal of problematic fluorescent dye artifacts is also described. Comparison studies in over 100 samples have verified that these miniSTR primers can provide fully concordant results to commercial STR kits and can provide improved signal from degraded DNA specimens. These miniplex sets should prove valuable in the analysis of samples where allele dropout and reduced sensitivity of larger STR alleles occurs.  相似文献   

16.
Analysis of short tandem repeat (STR) markers currently represents the most useful instrument in the field of forensic genetics. The problem with forensic material is the degradation of the sample material. In recent years, several papers have demonstrated that short amplicon STR (miniSTR) represents one of the most useful tools for analyzing degraded DNA samples.In the present study, we attempted to develop a short amplicon STR multiplex system (autosomal and y-chromosomal) for analyzing degraded DNA using some newly designed primer sets for a multiplex polymerase chain reaction (PCR) systems for typing.An assay of degraded DNA samples using the designed multiplex systems, including artificially degraded samples and degraded forensic casework samples, proved remarkably effective. Comparing the multiplex with commercial kits, first results show a well success rate.  相似文献   

17.
Preparation of degraded human DNA under controlled conditions   总被引:7,自引:0,他引:7  
DNA typing through analysis of short tandem repeats (STRs) and mitochondrial DNA (mtDNA) by means of the polymerase chain reaction (PCR) and sequencing are the common methods for the forensic identification of persons and reconstruction of kinship, especially when skeletal human remains have to be analyzed. Furthermore, samples typically found at crime scenes may be both quantitatively and qualitatively inadequate since they may contain very scarce and often degraded DNA due to exposure to heat, light, humidity, and microorganisms. In order to improve the performance of STR typing technology in those cases where DNA availability is limited, it would be desirable to have a source of degraded DNA with known properties. For this purpose, we have developed a method to prepare artificially degraded DNA under controlled conditions. By treatment of genomic DNA with sonication and DNAse I we have produced DNA fragments within a defined range of lengths. STR typing of this degraded DNA with a commercially available multiplex kit could only produce partial profiles as indicated by the absence of STR alleles with sizes >200 bp. This artificially degraded DNA can be used for the improvement and standardization of STR typing protocols when only highly degraded DNA is available for analysis.  相似文献   

18.
The HIrisPlex-S system, targeting a total of 41 SNPs, allows the simultaneous eye, hair and skin color prediction from DNA. In the present study, we developed a massive parallel sequencing (MPS) multiplex assay in order to genotype all the HIrisPlex-S markers in degraded casework samples. PCR amplicons sizes of target regions were kept below 180 bp, in order to allow analysis of degraded DNA samples. Individuals with known phenotype, artificially degraded DNA samples and a set of 2800M control DNA dilutions were sequenced on a Ion PGM System, in order to evaluate the concordance testing results and the forensic suitability of this 41-plex MPS assay. Full and reliable profiles could be obtained with 0.1 ng of input DNA. The increment of the number of PCR cycles results in improvement of sensitivity or in typing results but an increase of artifacts were also observed.  相似文献   

19.
目的 研究建立法医DNA标准物质备选细胞基因组STR基因座等位基因片段长度标准定值的方法.方法 利用有机法提取HPF和HSSM细胞基因组DNA并进行STR复合扩增,将产物进行电泳检测.利用Gene Mapper软件分析电泳结果,记录STR基因座等位基因的数值,并对目前我国公安系统应用较为广泛的DNATyperTM15、IdentifilerTM两种试剂盒扩增产物进行相应的DNA片段长度(bp)统计以及定值.结果 HPF为男性个体细胞,HSSM为女性个体细胞.HPF和HSSM细胞DNATyperTM15系统等位基因片段长度范围分别为126.26±0.05~367.53±0.20bp和125.33±0.07~370.08±0.17bp,IdentifilerTM系统等位基因片段长度范围分别为117.22±0.04~340.02±0.08bp和117.21±0.03~323.86±0.09bp.结论 对STR基因座等位基因片段长度进行标准定值,可为法医DNA标准物质提供有效的溯源途径.  相似文献   

20.
Three commercially available integrated rapid DNA instruments were tested as a part of a rapid DNA maturity assessment in July of 2018. The assessment was conducted with sets of blinded single-source reference samples provided to participants for testing on the individual rapid platforms within their laboratories. The data were returned to the National Institute of Standards and Technology (NIST) for review and analysis. Both FBI-defined automated review (Rapid DNA Analysis) and manual review (Modified Rapid DNA Analysis) of the datasets were conducted to assess the success of genotyping the 20 Combined DNA Index System (CODIS) core STR loci and full profiles generated by the instruments. Genotype results from the multiple platforms, participating laboratories, and STR typing chemistries were combined into a single analysis. The Rapid DNA Analysis resulted in a success rate of 80% for full profiles (85% for the 20 CODIS core loci) with automated analysis. Modified Rapid DNA Analysis resulted in a success rate of 90% for both the CODIS 20 core loci and full profiles (all attempted loci per chemistry). An analysis of the peak height ratios demonstrated that 95% of all heterozygous alleles were above 59% heterozygote balance. For base-pair sizing precision, the precision was below the standard 0.5 bp deviation for both the ANDE 6C System and the RapidHIT 200.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号