首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
This work presents the validation of a new immunological assay, the One-Step™ enzyme-linked immunosorbent assay (ELISA) tests from International Diagnostic Systems Corp. for the screening of drugs of abuse (cannabis, amphetamines, opiates, and cocaine) in human hair, with subsequent GC–MS confirmation. After decontamination and segmentation into small pieces, 50 mg of hair sample were incubated in 1 ml of methanol during 16 h at 40 °C. A 100 μL aliquot was collected and evaporated to dryness in presence of 100 μL of methanol/hydrochloric acid (99:1, v/v) to avoid amphetamines loss. The dried extract was dissolved in 100 μL of the “sample and standard diluent” solution included in the kit. This solution was submitted to analysis according to the recommended instructions of the manufacturer. During the validation phase, GC–MS confirmations were conducted according to our fully validated and published methods for opiates, cocaine, cannabis, and amphetamines determinations in hair. In a last development step, these procedures were slightly modified to directly confirm ELISA results by GC–MS using the methanolic extract. Ninety-three specimens were simultaneously screened by the ELISA tests (103 for tetrahydrocannabinol (THC)) and confirmed by GC–MS. Twenty were found positive for cannabis (THC: 0.10–6.50 ng/mg), 21 for cocaine (0.50–55.20 ng/mg), 24 for opiates (6-acetylmorphine (6-AM): 0.20–11.60 ng/mg, MOR: 0.20–8.90 ng/mg, codeine (COD): 0.20–5.90 ng/mg), and 13 for amphetamines (AP: 0.20 and 0.27 ng/mg, methamphetamine (MAP): 0.30 and 1.10 ng/mg, methylenedioxymethamphetamine (MDMA): 0.22–17.80 ng/mg). No false negative results were observed according to the Society of Hair Testing's (SoHT) cutoffs (0.5 ng/mg for cocaine, 0.2 ng/mg for opiates and amphetamines, and 0.1 ng/mg for THC). The One-Step™ ELISA kits appear suitable due to their sensitivity and specificity for drug of abuse screening in hair. This technology should find interest in workplace drug testing or driving license regranting, especially when many samples have to be tested with a high rate of negative samples, as ELISA is an easy and high-throughput method.  相似文献   

2.
Organic impurities of methamphetamine may show different patterns by synthesis. In the present study, we tried to find the impurities reflecting the conditions of synthesis by comparing impurity patterns of the methamphetamine samples synthesized by different methods. Sixteen methamphetamine samples were synthesized from ephedrine and pseudoephedrine by the three different manufacturing methods of Emde, Nagai and Moscow. The synthesized samples were extracted with ethyl acetate containing four internal standards, and the patterns of the organic impurities were investigated by GC-MS and GC-FID . Through the investigation, we found 10 peaks appearing in the latter part of GC chromatograms are characteristic to synthesis. The areas of the selected peaks were converted to the variables suitable for the statistical calculation, and the synthesized samples could be classified into four groups through the resultant cluster analysis.  相似文献   

3.
In this study, stable isotope ratio analysis was used to track the precursor information of methamphetamine. The δ13C and δ15N values of 30 nature ephedra plants, 12 synthetic ephedrine/pseudoephedrine (ephedrine), 14 natural ephedrine, and 987 seized methamphetamine samples were measured and compared. Due to different weather and earth conditions, the δ13C and δ15N values of ephedra plants grown in the east and the west of Inner Mongolia showed great difference. The δ15N values of ephedra plants were consistent with related ephedrine extracted from them. Moreover, the criteria to infer the synthetic origin of ephedrine were set up after the analysis of natural and synthetic ephedrine samples. Finally, the precursor origins of 949 seized methamphetamine samples synthesized by Emde and Nagai method were tentatively inferred. Influenced by different preprecursors, the δ13C values of seized methamphetamine samples that synthesized from P2P also showed great difference, and this result is consistent with the reported data.  相似文献   

4.
A 23-year-old man was found on a raised hide in lying position, the head wrapped in a plastic bag connected with a helium gas cylinder by a polypropylene tube. The autopsy did not show any specific findings nor did the routine toxicological analysis reveal significant information regarding the cause of death (BAC 0.9 mg/g, diphenhydramine 0.81 μg/ml in heart serum). For the detection of helium in the lungs, gas samples from both lungs were collected by a method ensuring minimal dilution. Gas analyses were performed using a GC–MS with a split–splitless injector and a headspace syringe. As carrier gas the commonly used helium was replaced by nitrogen. Helium was found in clearly elevated concentrations in gas samples from both lungs. Therefore, suffocation by breathing helium enriched, and thus oxygen deficient atmosphere, can strongly be assumed as the cause of death.  相似文献   

5.
The aim of this study was to assess the effectiveness of two current on-site oral fluid (OF) drug detection devices (OraLab and Dräger), as part of the Spanish participation in the Roadside Testing Assessment Project (ROSITA Project). The study was done in collaboration with the Spanish Traffic Police, in Galicia (NW Spain), during 2004 and 2005. A total of 468 drivers selected at the police controls agreed to participate through informed consent. In addition, saliva samples were collected and sent to the laboratory to confirm the on-site results. For this purpose, two different analytical liquid chromatography–mass spectrometry (LC–MS) methods were used to detect 11 drugs or metabolites in a 300 μL sample. Simultaneous analysis of morphine, 6-acetylmorphine, amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB, cocaine and benzoylecgonine was carried out using 100 μL of oral fluid, after an automated solid phase extraction. A different LC–MS method was performed to detect Δ9-THC in 200 μL of oral fluid using liquid–liquid extraction with hexane at pH 6. Both methods were fully validated, including linearity (1–250 ng/mL, 2–250 ng/mL) recovery (>50%), within-day and between-day precision (CV < 15%), accuracy (mean relative error < 15%), limit of detection (0.5 and 1 ng/mL), quantitation (1 and 2 ng/mL) and matrix effect. All of the positive cases and a random selection of 30% of the negatives were analyzed for confirmation analysis. Good results (sensitivity, specificity, accuracy, positive predictive value and negative predictive value > 90%) were obtained for cocaine and opiates by OraLab, and for cocaine by Dräger. However, the results for the other compounds could be improved for both detection devices. Differences in the ease of use and in the interpretation mode (visual or instrumental) were observed.  相似文献   

6.
γ-Hydroxybutyrate (GHB) is an increasingly popular drug of abuse that causes stimulation, euphoria, anxiolysis or hypnosis, depending on the dose used. Low doses of the drug are used recreationally, and also implicated in drug-facilitated sexual assaults. Because of the unusually steep dose–response curves, accidental GHB overdosing, leading to coma, seizures or death can occur. Being a controlled substance, GHB is often substituted with its non-scheduled precursors γ-butyrolactone (GBL) and 1,4-butanediol (BD), which are rapidly metabolized into GHB in the body. Here we describe an assay for GHB, GBL and BD in blood and/or urine samples. GHB and BD were extracted from diluted 200 μL aliquots of samples with t-butylmethylether (plus internal standard benzyl alcohol) in test tubes preloaded with NaCl. After acidification and centrifugation the solvent phase was transferred to a test tube preloaded with Na2SO4, incubated for 30 min, centrifuged again, and evaporated in vacuum. The residue was mixed with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA) in acetonitrile, and injected into a GC–MS. When analyzing GBL, the salting-out step was omitted, and analysis was performed with a GC–FID apparatus. As revealed by the validation data this procedure is suitable for quantitative determination of GHB and its precursors in blood and/or urine samples.  相似文献   

7.
The purpose of this study was to evaluate the efficiency of the Cozart® RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart® RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart® RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography–mass spectrometry (GC–MS). The samples were stored frozen at −20 °C until analysis by GC–MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC–MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

8.
Impurity profiles of methamphetamine tablets seized in Thailand have been investigated. The samples are extracted with small amounts of ethyl acetate under alkaline condition and the extracts are analyzed by capillary gas chromatography. Nine compounds (1,2-dimethyl-3-phenylaziridine, ephedrine, methylephedrine, N-formylmethamphetamine, N-acetylmethamphetamine, N-formylephedrine, N-acetylephedrine, N,O-diacetylephedrie, methamphetamine dimer) are identified as impurities in methamphetamine tablet. Caffeine and ethyl vanillin are also detected as diluents and/or adulterants, and acetylcodeine monoacetylmorphine and diacetylmorphine are contained in many samples. In addition, trans-3,4-dimethyl-5-phenyl-2-oxazolidone is newly found as an impurity. For characterization and comparison of methamphetamine tablet exhibits, intensely and commonly detectable nine peaks are selected as the factor for multivariate analysis. The procedures reported here permit classification of 250 analyzed exhibits into five groups and characterization of classified groups.  相似文献   

9.
目的 分析不同案件缴获的“摇头丸”主要成分和添加物,为确定“摇头丸”的合成路线、非法来源提供依据.方法 以GC/MS检测法为主要检测方法.结果 检验的14个“摇头丸”主要成分为甲基苯丙胺和咖啡因,其中含有少量的其他杂质如麻黄碱和氯胺酮等.结论 检测的14个“摇头丸”样本其中12个含甲基苯丙胺,实为冰毒成分,1个为咖啡因均不属于摇头丸.  相似文献   

10.
A fast and simple method to detect some commonly abused illicit drugs, amphetamine, methamphetamine, 3,4-methylendioxy-amphetamine (MDA), 3,4-methylendioxy-methamphetamine (MDMA), 3,4-methylendioxy-N-ethylamphetamine (MDEA) and phencyclidine (PCP) in urine using solvent microextraction (SME) combined with gas chromatography (GC) analysis has been developed. The extraction is conducted by suspending a 2 μl drop of chloroform in a 2 ml urine sample. Following 8 min of extraction, the organic solvent is withdrawn into the syringe and injected into a GC with a pulsed discharge helium ionization detector (PDHID).The effects of different extraction solvents and times, pH and sample preparation were studied. The optimized method was capable of detecting drugs in urine at concentrations below Substance Abuse and Mental Health Services Administration (SAMHSA) established cut-off values for preliminary testing. Good linearity and reproducibility of extraction were obtained. The limits of detection were 0.5 μg/ml for amphetamine, 0.1 μg/ml for methamphetamine and MDA, 0.05 μg/ml for MDMA, 0.025 μg/ml for MDEA and 0.015 μg/ml for PCP. Relative standard deviation (R.S.D.) values ranged between 5 and 20% for the studied drugs.  相似文献   

11.
Due to their widespread use in domestic and commercial premises, polyurethane foams, as either fragmented or bulk foam, are types of evidence commonly found at crime scenes. The traditional approach to determining the evidential value of polyurethane foam (PF) involves comparing recovered and control fragments under low and high magnification, under various lighting conditions, as well as the comparison of their respective dye spectra. As with most forms of trace evidence, chemical comparison is also desirable. In this work, two approaches to chemically comparing foam fragments were investigated, i.e. inductively coupled plasma–optical emission spectrometry (ICP–OES) analysis of the Tin (Sn) content in different foam types; and gas chromatography–flame ionization detection (GC–FID) analysis of soluble components in PFs mobilized by dichloromethane. Seven different foam types were studied and their Sn content was found to be different. They also produced characteristic GC–FID chromatographic profiles whose compounds were identified with gas chromatography–mass spectrometry (GC–MS) analysis. This study suggests that incorporating chemical data obtained from GC–FID/GC–MS and ICP–OES into a case involving PF could be advantageous, as this will enable the forensic scientist to broaden the comparison between control and recovered fragments, and further assess the strength of the evidence. However, ICP–OES analysis is a destructive technique with a relatively short sample turnaround time, whilst GC–FID analysis is more time-consuming and non-destructive, requiring corroboration with GC–MS data. The values of these two analytical techniques in the forensic chemical characterization of PFs are discussed.  相似文献   

12.
The isotope ratios of amphetamine type stimulants (ATS) depend as well on the precursor as the synthetic pathway. For clandestine production of amphetamine and methamphetamine, 1-phenyl-2-propanone (P2P, benzylmethylketone) is a commonly used precursor.Our aim was to determine the variation of the isotope ratios within precursor samples of one manufacturer and to compare seized samples of unknown sources to these values. δ13CV-PDB, δ2HV-SMOW and δ18OV-SMOW isotope ratios were determined using elemental analysis (EA) and gas chromatography (GC) coupled to an isotope ratio mass spectrometer (IRMS). The comparison of all seized samples to the data of the samples of one manufacturer revealed considerable differences. The results show that IRMS provides a high potential in differentiating between precursors from different manufacturers for the clandestine production of ATS and identifying corresponding sources.  相似文献   

13.
We present a validated method for the simultaneous analysis of basic drugs which comprises a sample clean-up step, using mixed-mode solid-phase extraction (SPE), followed by LC–MS/MS analysis. Deuterated analogues for all of the analytes of interest were used for quantitation. The applied HPLC gradient ensured the elution of all the drugs examined within 14 min and produced chromatographic peaks of acceptable symmetry. Selectivity of the method was achieved by a combination of retention time, and two precursor-product ion transitions for the non-deuterated analogues. Oral fluid was collected with the Intercept®, a FDA approved sampling device that is used on a large scale in the US for workplace drug testing. However, this collection system contains some ingredients (stabilizers and preservatives) that can cause substantial interferences, e.g. ion suppression or enhancement during LC–MS/MS analysis, in the absence of suitable sample pre-treatment. The use of the SPE was demonstrated to be highly effective and led to significant decreases in the interferences. Extraction was found to be both reproducible and efficient with recoveries >76% for all of the analytes. Furthermore, the processed samples were demonstrated to be stable for 48 h, except for cocaine and benzoylecgonine, where a slight negative trend was observed, but did not compromise the quantitation. In all cases the method was linear over the range investigated (2–200 μg/L) with an excellent intra-assay and inter-assay precision (coefficients of variation <10% in most cases) for QC samples spiked at a concentration of 4, 12 and 100 μg/L. Limits of quantitation were estimated to be at 2 μg/L with limits of detection ranging from 0.2 to 0.5 μg/L, which meets the requirements of SAMHSA for oral fluid testing in the workplace. The method was subsequently applied to the analysis of Intercept® samples collected at the roadside by the police, and to determine MDMA and MDA levels in oral fluid samples from a controlled study.  相似文献   

14.
Nineteen crystalline methamphetamine ('ice') seizures captured by the Australian Federal Police (AFP) at the Australian border between 1998 and 2002 were analysed. Using a modified gas chromatograph-mass spectrometry (GC-MS) impurity profiling approach of these samples we have identified >30 compounds associated with methamphetamine and/or its synthetic route. Major impurities detected include 1,2-dimethyl-3-phenylaziridine 8, dimethylamphetamine 14, N-formylmethamphetamine 24, N-acetylmethamphetamine 25, 1,3-dimethyl-2-phenylnaphthalene 32, 1-benzyl-3-methylnaphthalene 33 and methamphetamine dimer 34. These data are suggestive of ephedrine/pseudoephedrine as the main precursor of the 'ice' samples seized during 1998-2002. Additionally the two naphthalenes 32 and 33 further identified that 15 items in 9 seizures were produced via the more specific ephedrine/hydriodic acid/red phosphorus method. One sample comprised 75% dimethylamphetamine and 9.7% methamphetamine, representing the first Australian seizure of imported dimethylamphetamine reported.  相似文献   

15.
16.
The antipsychotic drug clotiapine (Entumine®) has been marketed for more than 35 years, however there is little published data on the therapeutic and toxic concentrations of this drug. To fill this gap, two rapid and sensitive methods were developed for the determination of clotiapine (2-chloro-11-(4-methyl-1-piperazinyl)dibenzo-[b,f][1,4]-thiazepine), in human plasma and post-mortem blood and tissue samples. After simple liquid–liquid extraction at pH 9.5 with n-hexane/dichloromethane (85/15, v/v), clotiapine was quantitated by HPLC-DAD and by GC-NPD. The calibration curve was linear between 10 and 1000 μg/L. The limit of detection (LOD) and the limit of quantification (LOQ) were found to be 2 and 6 μg/L for the GC-NPD method and 5 and 15 μg/L for the HPLC-method, respectively. These methods were applied to 12 plasma samples from patients treated with clotiapine, to seven autopsy cases and to one case of driving under the influence of drugs (DUID). Concentrations ranged for the clotiapine-treated patients between 6 and 155 μg/L (mean 46 μg/L), and for the autopsy cases between 22 and 341 μg/L (mean 123 μg/L).  相似文献   

17.
Methamphetamine hydrochloride is one of the most widely used illicit drugs in the Philippines. In this study, we describe the application of cluster analysis of trace impurities in the profiling of the seized methamphetamine drug samples. Thirty milligrams of a homogenized drug sample were dissolved in 1 mL of pH 10.5 buffer solution and extracted with ethyl acetate containing three internal standards. The trace impurities were identified using gas chromatography-mass spectrometry (GC-MS) and quantified by gas chromatography with a flame ionization detector (GC-FID). Following previously reported methodologies, 30 impurity peaks were selected from the GC-FID chromatograms. The peak areas and retention times were referenced to the internal standards. The peak areas of the selected peaks were then grouped for cluster analysis. In order to check for consistency of clustering, two further cluster analyses were performed using 40 and 50 impurity peaks. Changes in clustering were observed in going from 30 to 40 impurity peaks, while analyses using 40 and 50 impurity peaks gave similar results. Thus, for the seized drug samples used in this study, cluster analysis using at least 40 impurity peaks showed better consistency of clustering as compared to analysis using 30 peaks only. Ten of the impurity peaks were identified, of which four were identified for the first time in methamphetamine drug samples. These are p-bromotoluene, N-benzyl amphetamine, N-ethyl amphetamine, and N-ethyl methamphetamine. The presence of phenyl-2-propanone (P2P), N,N-dimethyl amphetamine, and N-formyl amphetamine is indicative that these casework samples were synthesized using the Leuckart method.  相似文献   

18.
Solid-phase microextraction (SPME) is a relatively new technique in which a small, polymer-coated fiber is employed to extract volatile and semivolatile organic compounds from the sealed headspace above a questioned sample. SPME, coupled with gas chromatography/mass spectrometry (GC/MS), was used to characterize impurities in illicit methamphetamine samples. Trace impurities present in a specimen were tentatively identified using mass-spectral databases and included 1,2-dimethyl-3-phenyl-aziridine (indicating synthesis via a halogenated ephedrine intermediate), ethyl vanillin (a flavoring compound), and caffeine (a stimulant used as cutting agent). The types and numbers of organic compounds sampled by SPME were compared with those collected by various solvent extraction protocols. In addition to unambiguously confirming the presence of methamphetamine, SPME-GC/MS analyses detected approximately 30 more organic analytes than were found by GC/MS following the ethyl acetate extraction method adopted by the United Nations International Drug Control Programme. SPME-GC/MS is a superior method for generating material "fingerprint" profiles in methamphetamine samples. The detection and characterization of increased points of comparison in drug samples provide more detailed chemical signatures for both intelligence and operational information.  相似文献   

19.
The applicability of capillary electrophoresis (CE) with a UV detector using highly sulfated gamma-cyclodextrin as a chiral selector was examined for analysis of impurities in seized methamphetamine. Samples of methamphetamine-hydrochloride dissolved in water at a high concentration (20 mg/mL) were analyzed. Electrokinetic injection has an advantage over hydrodynamic injection for improving the detection of trace impurities. Small peaks of the precursor impurities, such as (1R,2S)-(-)-ephedrine and (1S,2S)-(+)-pseudoephedrine, were detected and quantified without extraction. The seized drugs could be classified into three groups based on the contents of the two impurities.  相似文献   

20.
In order to aid the interpretation of hair results from methamphetamine (MA) abusers the MA and amphetamine (AP) concentrations in 2070 hair samples were statistically evaluated. The MA and AP concentrations in hair were put into three groups arbitrarily representing low, medium and high ranges and the metabolite-to-parent drug ratios of each group were examined. The concentration ranges proposed here were also applied to the interpretation of five authentic cases. The low, medium and high ranges of MA were 0.5–4.2, 4.2–24.5 and 24.5–608.9 ng/mg and those of AP were 0.1–0.4, 0.4–1.7 and 1.7–41.4 ng/mg. The AP-to-MA ratios showed large variation but a tendency that it decreased as the MA ranges increased. This evaluation was very useful to presume the severity of individuals’ MA abuse and to provide law enforcement agencies more understandable information. It could also facilitate the court's decision regarding specific circumstances surrounding the drug-related crimes.  相似文献   