首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Organic impurities of methamphetamine may show different patterns by synthesis. In the present study, we tried to find the impurities reflecting the conditions of synthesis by comparing impurity patterns of the methamphetamine samples synthesized by different methods. Sixteen methamphetamine samples were synthesized from ephedrine and pseudoephedrine by the three different manufacturing methods of Emde, Nagai and Moscow. The synthesized samples were extracted with ethyl acetate containing four internal standards, and the patterns of the organic impurities were investigated by GC-MS and GC-FID . Through the investigation, we found 10 peaks appearing in the latter part of GC chromatograms are characteristic to synthesis. The areas of the selected peaks were converted to the variables suitable for the statistical calculation, and the synthesized samples could be classified into four groups through the resultant cluster analysis.  相似文献   

2.
Classification of seized methamphetamine by impurity profiling can provide very useful information in criminal investigations of drug traffic routes, sources of supply and relationships between seizures. The aim of this study is to improve and develop an analytical method for detecting impurities such as starting materials and by-products in illegally prepared methamphetamine.HCl samples. A 50mg sample of methamphetamine.HCl was dissolved in 1 ml of buffer solution (four parts 0.1M phosphate buffer pH 7.0 and one part 10% Na2CO3). Impurities were extracted with 0.5 ml of ethyl acetate containing four internal standards (ISs) (n-decane, n-pentadecane, n-nonadecane and n-hexacosane) and analyzed by gas chromatography (GC) using a flame ionization detector (FID) on a DB-5 capillary column (0.32 mmi.d. x 30 m, film thickness 1.0 microm). The use of a middle-bore column offered better separation of the impurity peaks. The correction of the retention times of impurity peaks with four ISs made peak identification very accurate for subsequent data processing. Twenty-four characteristic peaks were selected for comparison and similarity and/or dissimilarity between samples, and the data were evaluated by the Euclidean distance of the relative peak areas after logarithmic transformation. The results indicate that the present method would be useful for methamphetamine impurity profiling.  相似文献   

3.
Impurities in 48 methamphetamine (MA) samples were analyzed by liquid-liquid extraction (LLE) and headspace solid-phase microextraction (HS-SPME) methods. MPS-2 autosampler was used to improve reproducibility of SPME method, and nonadecane (C(19)) diluted with potassium bromide (KBr) powder was used as an internal standard for standardizing retention time. Impurities identified by SPME method showed different patterns compared with LLE method. Non-volatile impurities like methamphetamine dimer were not identified by SPME method, but some volatile impurities like diphenylketone, caprolactam and lots of unknowns were identified only by SPME method. 1-Phenyl-2-propanone (P2P), 1-phenyl-2-propanol and benzylcyanide peaks could be discriminated clearly by SPME method without interference of amphetamine, an artifact originates from MA degradation. Differences in the impurity patterns resulted in different clustering results. When 48 MA samples were classified into 5 LLE and 5 SPME clusters, cross-matching of the clusters resulted in 8 sub-clusters. It shows that combination of the different extraction methods can distinguish the differences which cannot be distinguished by LLE or SPME method alone, and can improve reliability of the profiling results.  相似文献   

4.
Impurity profiles of methamphetamine tablets seized in Thailand have been investigated. The samples are extracted with small amounts of ethyl acetate under alkaline condition and the extracts are analyzed by capillary gas chromatography. Nine compounds (1,2-dimethyl-3-phenylaziridine, ephedrine, methylephedrine, N-formylmethamphetamine, N-acetylmethamphetamine, N-formylephedrine, N-acetylephedrine, N,O-diacetylephedrie, methamphetamine dimer) are identified as impurities in methamphetamine tablet. Caffeine and ethyl vanillin are also detected as diluents and/or adulterants, and acetylcodeine monoacetylmorphine and diacetylmorphine are contained in many samples. In addition, trans-3,4-dimethyl-5-phenyl-2-oxazolidone is newly found as an impurity. For characterization and comparison of methamphetamine tablet exhibits, intensely and commonly detectable nine peaks are selected as the factor for multivariate analysis. The procedures reported here permit classification of 250 analyzed exhibits into five groups and characterization of classified groups.  相似文献   

5.
The applicability of capillary electrophoresis (CE) with a UV detector using highly sulfated gamma-cyclodextrin as a chiral selector was examined for analysis of impurities in seized methamphetamine. Samples of methamphetamine-hydrochloride dissolved in water at a high concentration (20 mg/mL) were analyzed. Electrokinetic injection has an advantage over hydrodynamic injection for improving the detection of trace impurities. Small peaks of the precursor impurities, such as (1R,2S)-(-)-ephedrine and (1S,2S)-(+)-pseudoephedrine, were detected and quantified without extraction. The seized drugs could be classified into three groups based on the contents of the two impurities.  相似文献   

6.
Methamphetamine (MA) is one of the most frequently abused drugs worldwide. The aim of this study is to improve the analytical method for profiling MA impurity in order to compare and classify MA crystals seized in different countries and to investigate the relationships between seizures. To compare MA samples seized in Japan and Thailand, the following analytical method was adopted. A 50mg sample of MA.HCl was dissolved in 1ml of buffer solution (four parts 0.1M phosphate buffer, pH 7.0, and one part 10% Na(2)CO(3)), impurities were extracted with 0.5ml of ethyl acetate containing four internal standards (n-decane, n-pentadecane, n-eicosane and n-octacosane) and analyzed by gas chromatography with a flame ionization detector on a DB-5 capillary column (0.32mm i.d.x30m, film thickness 1.0mum). Fourteen characteristic peaks on chromatograms were selected for the comparison and classification of samples, and the data were evaluated by the Euclidean distance of the relative peak areas after logarithmic transformation. Sixty-nine samples seized in Japan and 42 seized in Thailand were analyzed. The samples were classified into four groups roughly by cluster analysis. In addition, when it was difficult to compare samples that had fewer impurities on chromatograms obtained from liquid-liquid extraction (LLE), solid-phase microextraction (SPME) was effective. Because many characteristic peaks were detected using SPME, SPME made it easy to compare samples of high purity. The combination of LLE and SPME was useful for impurity profiling of MA samples seized in different countries.  相似文献   

7.
目的建立分子印迹固相萃取(MISPE)、GC/MS分析方法,用于血液中苯丙胺类毒品检测。方法 10mmol/L醋酸铵缓冲液(pH8.0)4倍稀释空白添加血液,1mL甲醇,1mL10mmol/L醋酸铵缓冲液(pH8.0)活化苯丙胺类分子印迹固相萃取柱;2×1mL去离子水、1mL60%的乙腈去离子水、1mL1%醋酸乙腈洗涤杂质;2×1mL1%甲酸/甲醇洗脱,洗脱液挥干定容,经GC/NPD、GC/MS分析检测。结果各种苯丙胺类毒品回收率均在90%以上,在20~5 000ng/mL浓度范围内线性关系良好,r2为0.995 7~0.998 9,LOQ在16~30ng/mL之间,LOD在8~15ng/mL之间。结论本方法回收率高,净化效果显著,稳定性好,杂质干扰少,可用于血液中低浓度苯丙胺类毒品的分析检测。  相似文献   

8.
Impurity profiling and classification of seized methamphetamine may play an important role in the interpretation of analytical results, the determination of the synthetic method employed, and the criminal investigations of drug traffic routes. Our study is focused on classifying seized methamphetamine samples according to the groups sorted by the types and quantities of impurities present in illicit methamphetamine samples. The samples (100 mg) were dissolved in 2 mL of potassium phosphate buffer (pH 7.0), extracted with 200 μL of ethyl acetate under basic condition, and then analyzed by gas chromatography-mass spectrometry (GC–MS) with a DB-1 capillary column (30 m × 0.25 mm i.d., 0.25 μm). Five impurities are used as criteria for the classification of seized methamphetamine samples by Emde and Nagai method. A total of fifty-two samples of seized methamphetamine were analyzed by GC–MS and classified by five organic impurities, and then sorted into four groups, which are Nagai type, Emde Type, Undetermined I type, and Undetermined II type.  相似文献   

9.
Nineteen crystalline methamphetamine ('ice') seizures captured by the Australian Federal Police (AFP) at the Australian border between 1998 and 2002 were analysed. Using a modified gas chromatograph-mass spectrometry (GC-MS) impurity profiling approach of these samples we have identified >30 compounds associated with methamphetamine and/or its synthetic route. Major impurities detected include 1,2-dimethyl-3-phenylaziridine 8, dimethylamphetamine 14, N-formylmethamphetamine 24, N-acetylmethamphetamine 25, 1,3-dimethyl-2-phenylnaphthalene 32, 1-benzyl-3-methylnaphthalene 33 and methamphetamine dimer 34. These data are suggestive of ephedrine/pseudoephedrine as the main precursor of the 'ice' samples seized during 1998-2002. Additionally the two naphthalenes 32 and 33 further identified that 15 items in 9 seizures were produced via the more specific ephedrine/hydriodic acid/red phosphorus method. One sample comprised 75% dimethylamphetamine and 9.7% methamphetamine, representing the first Australian seizure of imported dimethylamphetamine reported.  相似文献   

10.
Analysis of impurities in methamphetamine (MA) can be used to characterize MA seizures, investigate the relationship among MA seizures, and provide information on their synthetic routes. Recently, chemically derivatized MA, such as tert-butoxycarbonyl (t-Boc) MA, has been seized and attracted attention because routine forensic analysis methods may fail to correctly identify them. Chemical derivatization is a simple method for protection and deprotection of a compound, and protection of MA using t-Boc can be used to mask the MA. Although t-Boc derivatization might alter the impurity profile of MA, the actual changes in the impurity profile have not been investigated. In this study, changes in the MA impurity profile with tert-butoxycarbonylation were explored. MA and some typical impurities were derivatized using di-tert-butyl dicarbonate and water. Analysis of the impurities in five MA samples by gas chromatography showed that peaks both appeared and disappeared for the deprotected MA compared with the original MA. However, typical impurities important for characterizing MA seizures were conserved after derivatization and deprotection. Most of the new peaks were speculated to be contaminants introduced during derivatization and deprotection. A peak giving a mass spectrum similar to that of t-Boc MA was detected in the chromatograms of t-Boc MA and deprotected MA. Although the origin of this peak was not determined, it might be a marker for the MA involving tert-butoxycarbonylation. These results indicate that tert-butoxycarbonylation can alter the MA impurity profile; therefore, care is needed when interpreting results for derivatized MA.  相似文献   

11.
Synchrotron radiation total reflection X-ray fluorescence spectroscopy (SR-TXRF) was utilized to analyze various trace elements in small amounts of drugs of abuse. Sample amounts of 1 microL solutions containing 10 microg of drugs (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, and heroin) were spotted on silicon wafers for direct analysis. In addition, a leaflet of marijuana was set directly on a silicon wafer, and opium in the form of a soft lump was smeared on another silicon wafer for analysis. In these experiments, about 10 pg of contaminant elements could be detected. For example, in a seized methamphetamine sample, iodine was found, which could be indicative of synthetic route. In seized 3,4-methylenedioxymethamphetamine samples, variable amounts of phosphorus, calcium, sulfur, and potassium were found, which could not be detected in a control 3,4-methylenedioxymethamphetamine sample. For marijuana and opium, two spectral patterns were obtained that were far different from each other and could be easily discriminated. Using SR-TXRF, pg amounts of each trace element in 10 microg of various drugs can be easily detected, which is not the case either for a standard TXRF experimental system or for other elemental analysis techniques.  相似文献   

12.
The profiling of impurities in methamphetamine (MA) using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) is described. The extraction of the impurities with an SPME fiber was examined under varying conditions. Optimal chromatograms were obtained when a 50 mg MA sample at 85 degrees C for 30 min was extracted using a fiber coated with divinylbenzene/carboxen/polydimethylsiloxane. MA samples from nine different origins were analyzed under optimized extraction conditions. Compounds related to MA such as benzaldehyde, benzyl alcohol, amphetamine, benzyl methyl ketone, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, N-acetylamphetamine, N-acetylmethamphetamine and N-formylmethamphetamine were detected in the chromatograms. Trace amounts of ethanol, diethyl ether and acetic acid were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different, depending on the sample. After the areas of the eight principal peaks were converted to their square root and logarithm, similarities among the samples were evaluated by Euclidian distance, cosine distance and correlation coefficient. The results showed that a combination of logarithmic conversion and cosine distance was the most suitable for discriminating and classifying the samples. HS-SPME/GC-MS is a simple and effective method for the extraction and identification of impurities. The present method, in combination with an appropriate statistical analysis, would be useful for developing a profile of impurities in MA.  相似文献   

13.
In this study fifty samples of crystalline methamphetamine obtained from antinarcotics police of Iran seized during the year 2010 were analyzed. In order to determine the chemical characteristics of these samples, anion test, Gas Chromatography-Mass Spectrometry (GC-MS) and Liquid Chromatography-Mass Spectrometry (LC-MS) were carried out on the samples. All of the samples containing methamphetamine tested positive for chloride anion. The range of methamphetamine hydrochloride content in these samples was 33-95%. One sample out of 50 contained no methamphetamine. The fact that 1,2-dimethyl-3-phenylaziridine was the most frequently found impurity in the analyzed samples, indicates that most of the methamphetamine samples seized in Iran have been synthesized from pseudoephedrine as starting material.  相似文献   

14.
Gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS) are commonly used for the impurity profiling of illegal drugs. For the impurity profiling of methamphetamine, it is very important to obtain information about impurities related to the manufacturing route and the precursor chemicals [B. Remberg, A.H. Stead, Drug characterization/impurity profiling, with special focus on methamphetamine: recent work of the United Nations International Drug Control Programme, Bull. Narcotics LI (1999) 97-117 ]. There are many artifact impurities arising from the preparation of samples and conditions of GC. Moreover, some impurities pose a barrier to the statistical processing of methamphetamine profiling. We investigated capillary GC analysis using pulsed splitless (PS/L) injection to minimize the thermal decomposition of impurities at the injection port and improve the transfer of samples into the column. We confirmed that the optimal conditions of PS/L-mode are 230 degrees C (injection temperature), 50 psi (pulsed pressure) and 1.1 min (pulsed time) for the methamphetamine profiling. Based on the impurity profiles of 48 methamphetamine crystals in PS/L-mode, we can achieve very easy handling and obtained, good results.  相似文献   

15.
A simple and rapid method for direct simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA) and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in seized tablets was developed using gas chromatography with flame ionization detection. Separation of all six underivatized amphetamines, including diphenylamine as internal standard, was performed in about 6 min, using SPB-50 capillary column. Amphetamine and methamphetamine eluted with negligible tailing while the other amphetamines had highly symmetrical peaks. Sensitivity per component on-column was in the nanogram range, and reproducibility from 2.6 to 6.6% at low concentration (2.4 microg/mL) and from 1.2 to 2.6% at high (70 microg/mL) concentration. The method has a wide linear range, from Limit of detection (LOD) to almost 200 microg/mL, thus allowing analysis of different samples across a wide range of possible concentrations of amphetamines. This simple, fast and precise method using gas chromatography--flame ionization detector (GC--FID), in conjunction with other methods (TLC, IR, HPLC), can be used for identification of amphetamines and direct determination in seized tablets, especially in laboratories with heavy workload.  相似文献   

16.
目的 分析不同案件缴获的“摇头丸”主要成分和添加物,为确定“摇头丸”的合成路线、非法来源提供依据.方法 以GC/MS检测法为主要检测方法.结果 检验的14个“摇头丸”主要成分为甲基苯丙胺和咖啡因,其中含有少量的其他杂质如麻黄碱和氯胺酮等.结论 检测的14个“摇头丸”样本其中12个含甲基苯丙胺,实为冰毒成分,1个为咖啡因均不属于摇头丸.  相似文献   

17.
Abstract:  In Japan, the most common illicit drug is methamphetamine. It is possible to trace the origin of this drug by analyzing its organic and inorganic impurities and/or byproducts using several methods, such as GC, GC/MS, and inductively coupled plasma-mass spectrometry (ICP-MS). As reported here, one other method includes comparison of the striation lines of polymer sheet layers from packaging using a polarized light method. Other alternative methods include analyzing the heat sealer pattern, layer thickness surface characteristics, and/or components of polymer sheet layers using infrared spectroscopy. Several of these alternative methods were used to analyze the origins of 29 packages confiscated from three regions over a 1000 km distance in Japan. Results indicated that packages seized from different regions had some polymer sheet layers which contained striation lines and heat sealer patterns that were similar.  相似文献   

18.
In Hong Kong, ecstasy tablets are more commonly known as "Fing Tau Yuen", literally meaning "Shake Head Pills". The tablets contain mainly amphetamine-type stimulants (ATS) including 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MA) and/or ketamine. Adulterant such as caffeine was also detected in the tablets. This paper reports a study on the impurity profiles of ecstasy tablets from 89 seizures in Hong Kong from 2002 to early 2004. Tablet samples were extracted by diethyl ether under alkaline condition and then analyzed by gas GC-MS. The chromatograms obtained were compared. A total of 19 identified impurities were selected as markers for impurity profiling. They are different precursors, intermediates and by-products. The data matrices were examined by hierarchical cluster analysis (HCA), and then the ecstasy tablets were classified into different groups. Cluster analysis of ecstasy tablets is shown to be capable of providing intelligence on clandestine laboratory networks.  相似文献   

19.
目的考察司来吉兰及其代谢物在尿液中的含量变化,并结合实际案例探讨手性分析区分甲基苯丙胺滥用与司来吉兰服用的可行性。方法采用CHIROBIOTICTM V2手性液相色谱柱对尿液样品进行手性分离和液相色谱-串联质谱(LC-MS/MS)法测定,并对司来吉兰服药志愿者尿样、疑服用司来吉兰的涉毒人员尿样进行甲基苯丙胺和苯丙胺的手性分析。结果服用5 mg司来吉兰后,尿液中司来吉兰的检出时限仅为7h。尿液中R(-)-甲基苯丙胺和R(-)-苯丙胺约在7h质量浓度最高,分别为0.86μg/m L和0.18μg/m L,并在80 h和168 h后无法检出。应用该方法成功分析了疑服用司来吉兰的涉毒人员尿液中甲基苯丙胺和苯丙胺的来源。结论甲基苯丙胺和苯丙胺的手性分析以及司来吉兰代谢物检测可区分甲基苯丙胺滥用与司来吉兰服用。  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号