首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   23篇
  免费   3篇
法律   26篇
  2024年   3篇
  2023年   13篇
  2021年   4篇
  2016年   1篇
  2015年   2篇
  2009年   1篇
  2000年   1篇
  1993年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
11.
Disposing of items of forensic relevance in bodies of water is one countermeasure offenders can use to avoid detection. The impact of immersion in water has been explored for blood, saliva, and semen; however, few studies have assessed touch DNA. Here we report on the effect of exposure to water on the persistence of touch DNA over prolonged periods of time. To evaluate the persistence of cells from touch DNA, after water exposure, three substrates and two water types were tested: plastic, metal, and ceramic, submerged into seawater or tap water. Diamond™ Nucleic Acid Dye was used to stain cells deposited by touch. Cell counts before and after water exposure were compared to investigate cell loss over time, ranging from 6 hours to 5 days. A logarithmic increase in the percent of cells lost was observed over time when the data for substrate and water type conditions were combined. Substrate type influenced the persistence of cells, with the metal substrate retaining cells longer than plastic or ceramic. The influence of water type appeared dependent on the substrate, with varied cell persistence on metal whereas plastic and ceramic recorded similar cell loss over time between water types. The ability to visualize cells after exposure to water could assist in triaging evidence within operational forensic laboratories and allow for targeted sampling. This proof-of-concept study demonstrated that greater than 50% of cells can persist on various items submerged in aqueous environments for at least 5 days, highlighting the possibility for downstream DNA testing.  相似文献   
12.
This study examines the pattern of rib injuries occurring in cases of fatal torso stab wounds in Ireland between 2011 and 2018. It has been suggested by previous studies that rib fractures are not commonly sustained in stab wounds to the torso. We wanted to ascertain whether this was the case, as our data suggested that rib fractures were frequent, and where a rib is fractured there is a higher chance of organ injury and death, making this an important area of study. One hundred and forty seven cases of fatal stab wounds from an eight-year period were retrospectively reviewed. Fatal stab wounds to other body areas, were excluded; leaving a total of 104 cases with stab wounds to the torso. We found that 69.2% of cases had rib injuries, a figure significantly higher than previously reported. Our data suggests that stab wounds to the torso often fracture ribs, putting the underlying organs at increased risk of injury and perhaps contributing to fatality. The amount of force needed to cause a rib fracture can be difficult to quantify and indeed from the high percentage of rib fractures sustained in our data it appears that the ribs may be fractured regardless of the amount of force used; this is borne out by the finding that self-inflicted injuries also caused rib fractures. Our study shows that other factors, such as anatomical positioning and wound depth may have a greater bearing than force in terms of whether a rib fracture is sustained.  相似文献   
13.
Measuring trajectory angles of bullet defects at a crime scene is an important part of crime scene investigation as these angles can be used for shooting incident reconstructions. The Washington State Patrol Crime Scene Response Team (WSP CSRT) had a desire to report and use measured trajectory angles. To report quantitative measurements, a statement of uncertainty for the measurement must also be reported due to an accreditation requirement through the ANSI National Accreditation Board (ANAB), through which the WSP CSRT is accredited. This evaluation examined the measurement uncertainty of the 3D laser scanning method that the WSP CSRT utilizes for measuring the vertical and azimuth angles from trajectory rods fitted to bullet defects. Three studies were performed which examined the variation of vertical and azimuth angle measurements from trajectory rods on flat surfaces, the variation of azimuth angle measurements from a trajectory rod on a curved surface, and a traceability study with known vertical and azimuth angle measurements. Seven common substrates were selected as target materials and were shot with 9 mm Luger and 0.45 Auto caliber bullets. A vehicle with one bullet defect was utilized for the curved surface study. The WSP's current fleet of Trimble X7 3D laser scanners, the WSP Criminal Investigation Division (CID) Detectives who operate these scanners, and the Forensic Scientists responsible for trajectory rod placement and angle measurements were utilized. An overall measurement uncertainty of +/− 2.6 degrees at an approximate 95% confidence interval was determined for all trajectory angles measured from trajectory rods.  相似文献   
14.
Physical matching methods are a family of well‐known methods that are utilized in order to determine whether two pieces of a tearable/breakable material used to be one object. When performing physical match of polymers, it is sometimes difficult to reach an unambiguous conclusion. This is due to various reasons. One is when the tear/fracture resides in an inaccessible or hidden‐from‐view region of the piece. Another is when the shape of the tear/fracture at the object's tear/fracture line is insufficient for deducing a complete match. Third is deficiency of material along this line. These are examples of processes where the line is affected so drastically, so that a match renders impossible. Specifically, when addressing elastic materials, the tear/fracture line may even be squashed. This may also be a reason for difficulty in performing a physical match. In this paper, a method is proposed where a match is alternatively achieved by means of photographic comparison of marks on the surface topography of the pieces‐in‐question. Comparisons of pairs of torn pieces of silicon rubber were made. The procedure involved photography of the surface topography the pieces. Then, the photographs were horizontally mirror‐flipped. Lastly, a comparison was made between two photographs: a photograph of one piece and a mirror‐flipped photograph of the opposite piece. The results show that after comparing the pieces to one another, only one unique pair turned out to be positively matched. Using the proposed method, not only the comparison is done by a more informative method (comparing to physical match), it is also more convenient, faster, less expensive, and technically simpler.  相似文献   
15.
At present, very little research has been devoted to investigating the ability of laser scanning technology to accurately measure height from surveillance video. The goal of this study was to test the accuracy of one particular laser scanner to estimate suspect height from video footage. The known heights of 10 individuals were measured using an anthropometer. The individuals were then recorded on video walking along a predetermined path in a simulated crime scene environment both with and without headwear. The difference between the known heights and the estimated heights obtained from the laser scanner software were compared using a one-way t-test. The height estimates obtained from the software were not significantly different from the known heights whether individuals were wearing headwear (p = 0.186) or not (p = 0.707). Thus, laser scanning is one technique that could potentially be used by investigators to determine suspect height from video footage.  相似文献   
16.
17.
The body of a 19‐year‐old male was found apparently concealed underneath bushes with recent head and facial trauma, and multiple superficial abrasions. Subsequently, it was discovered that the decedent had been running into objects and buildings following the ingestion the evening before of what was thought to be lysergic acid diethylamide (LSD). Blood staining of a nearby wall close to where the body was lying was in keeping with the described behavior. Toxicology revealed 3,4‐methylenedioxymethamphetamine (Ecstasy), in addition to two only recently available drugs 2‐(4‐bromo‐2,5‐dimethoxyphenyl)‐N‐[(2‐methoxyphenyl)methyl]ethanamine, (25B‐NBOMe), and 1‐(3,4‐methylenedioxyphenyl)‐2‐(1‐pyrrolidinyl)‐1‐butanone, (MDPBP). At autopsy, the skull was fractured with cerebral swelling, contusions, and subarachnoid hemorrhage. Death was due to blunt cranial trauma against a background of mixed drug toxicity. The case demonstrates a rare cause of death in a drug‐induced acute delirium, as well as highlighting two new designer street drugs that may result in significant aberrant behavior.  相似文献   
18.
Drawing forensic conclusions from an image or a video is known as “photographic content analysis.” It involves the analysis of an image, as well as objects, actions, and events depicted in images or video. In recent years, photographic depictions of objects suspected as illegal firearms have substantially increased, appearing on CCTV surveillance footage, captured by mobile phones and shared on social media. However, the law in Israel states that a person can be charged with illegally possessing a firearm only if it can be proven that the object is capable of shooting with lethal bullet energy. This becomes more challenging in cases where the firearm was not physically seized, and the evidence exclusively consists of images and video. In this study, photographic content analysis was applied to images and video where objects suspected as commercial or improvised firearms had been depicted. An image and event sequence reconstruction video databases of both firearms and replicas were created in order to better define firearm-specific functional morphological features. We demonstrate that it is possible to classify an object as a firearm by analyzing the functional, and not only the esthetic, morphology in images and video. It is also shown that event sequence reconstruction in video may be used to infer that an object suspected as a firearm has the capacity to shoot by confirming the occurrence of a shooting act or shooting process. Thus, photographic content analysis may be used to forensically establish that an object depicted in an image or a video is a firearm by ruling out other known scenarios, and without physically seizing it.  相似文献   
19.
TASER® weapons are conducted energy weapons (CEWs) that are frequently used by police departments around the world. CEWs can be deployed in two methods: drive stun application and probe deployment. This study aims to examine damages caused by TASER devices on fabrics and whether types of fabric material and TASER models could contribute to different damage features. Three types of white fabric were used, including 100% cotton, 100% polyester, and 65:35 polyester-cotton blend. Three models: TASER X26P, TASER X2, and TASER 7 were shot onto each type of fabric, with five repetitions each. Each damaged area on the fabric caused by a probe is a sample (n = 90) and was examined with a Keyence digital microscope. Images were captured by the Keyence microscope and measurements were recorded, including damage dimensions, fabric condition, evidence of burning, and extra findings. The presence of fused yarn ends was found to be statistically significant across the fabric types, and no damage features were found that may assist in the identification of TASER models. Other damage features including damage dimensions, discoloration, and fiber deformation were not found to be showing apparent differences according to statistical analysis. The conclusions made by this research should be used with caution due to the small sample size.  相似文献   
20.
The benzylation of three low molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved gas chromatography-mass spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1–10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na2CO3) in dichloromethane at 55°C for 2 h. This optimized set of conditions was then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. The protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where routine forensic analysis is carried out.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号