首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   315篇
  免费   6篇
各国政治   29篇
工人农民   5篇
世界政治   2篇
法律   260篇
中国政治   12篇
政治理论   12篇
综合类   1篇
  2024年   38篇
  2023年   150篇
  2021年   36篇
  2020年   3篇
  2017年   4篇
  2016年   1篇
  2015年   3篇
  2014年   1篇
  2013年   21篇
  2012年   9篇
  2011年   8篇
  2010年   11篇
  2009年   10篇
  2008年   5篇
  2007年   1篇
  2006年   4篇
  2005年   1篇
  2004年   3篇
  2001年   1篇
  2000年   2篇
  1998年   1篇
  1997年   2篇
  1991年   3篇
  1989年   1篇
  1984年   1篇
  1983年   1篇
排序方式: 共有321条查询结果,搜索用时 31 毫秒
41.
Identifying failure mechanisms in skeletal tissue allows a deeper understanding of the effects of specific projectile impacts on bone. While ballistic trauma in flat bones is largely researched, knowledge of how long bones react to gunshot impacts is limited in the literature. The impacts of deforming ammunition appear to produce higher levels of fragmentation; however, these have not been studied in depth. This study compares the damage to femora bone by HP 0.357 and 9 mm projectiles constructed with both full and semi-metal jackets. Impact experiments were undertaken on a single-stage light gas gun involving the use of a high-speed video camera and full reconstruction of the bones to ascertain fracture patterns occurring in the femora. Higher degrees of fragmentation are likened to the presence of semi-jacketed HP projectiles than jacketed HP projectiles. The observations of external facing beveled edges are believed to be associated with the increased separation of the jacket and lead core of projectiles. Additionally, experimentation has shown that the amount of kinetic energy lost postimpact is likely related to the presence or the absence of a metal jacket on an HP projectile. The observed data, therefore, suggest that the composition, rather than the configuration, of a projectile affects the type and extent of the damage.  相似文献   
42.
Anti-forensic technology can play an effective role in protecting information, but it can make forensic investigations difficult. Specifically, file-wiping permanently erases evidence, making it challenging for investigators to determine whether a file ever existed and prolonging the investigation process. To address this issue, forensic researchers have studied anti-forensic techniques that detect file-wiping activities. Many previous studies have focused on the effects of file-wiping tools on $MFT, $LogFile, and $DATA, rather than on Windows artifacts. Additionally, previous studies that have examined Windows artifacts have considered different artifacts, making it difficult to study them in a comprehensive manner. To address this, we focused on analyzing traces in 13 Windows artifacts of 10 file-wiping tools' operations in the Windows operating system comprehensively. For our experiments, we installed each file-wiping tool on separate virtual machines and checked the traces that the tools left behind in each artifact. We then organized the results in a database format. Our analysis revealed that most of the tools left traces on other artifacts, except for JumpList, Open&SavePidlMRU, and lnk. There were also some cases where traces remained on the other three artifacts. Based on our research, forensic investigators can quickly identify whether a file-wiping tool has been used, and it can assist in decision-making for evidence collection and forensic triage.  相似文献   
43.
The secondary dentin deposition that occurs after the tooth formation process results in a decrease in pulp cavity volume in adolescents and adults. The purpose of this critical review was to correlate pulpal and/or dental volume on cone-beam computed tomography (CBCT) with chronological age approximation. A subobjective was to investigate which methodology and CBCT technical parameters would be most appropriate to evaluate this correlation. This critical review followed the PRISMA guidelines, and it was conducted by a search through PubMed, Embase, SciELO, Scopus, Web of Science, Cochrane Library databases, as well as gray literature. Primary studies that used pulp volume, or pulp chamber to tooth volume ratio measured using CBCT were included. Seven hundred and eight indexed and 31 non-indexed records were identified. A qualitative analysis was performed including 25 selected studies with a total of 5100 individuals, age ranging from 8 to 87 years without sex predilection. The most used method was pulp volume/tooth volume. CBCT voxel size ranged between 0.09 and 0.5. Manual segmentation associated with threshold algorithms was used in most of the studies. Correlation between the pulp volume/tooth volume ratio was moderate: −0.66 for the upper central incisors, −0.59 for upper canines and −0.56 for lower canines. High heterogeneity was observed among the studies. It is concluded that pulp volume should be used with caution in age estimation. Evidence supports the preferable use of upper incisors with pulp volume/tooth volume ratio for age estimation. There is not enough evidence that voxel size interferes in age estimation by pulp volume.  相似文献   
44.
While canines are most commonly trained to detect traditional explosives, such as nitroaromatics and smokeless powders, homemade explosives (HMEs), such as fuel–oxidizer mixtures, are arguably a greater threat. As such, it is imperative that canines are sufficiently trained in the detection of such HMEs. The training aid delivery device (TADD) is a primary containment device that has been used to house HMEs and HME components for canine detection training purposes. This research assesses the odor release from HME components, ammonium nitrate (AN), urea nitrate (UN), and potassium chlorate (PC), housed in TADDs. Canine odor recognition tests (ORTs) were used with analytical data to determine the detectability of TADDs containing AN, UN, or PC. Headspace analysis by gas chromatography/mass spectrometry (GC/MS) with solid-phase microextraction (SPME) or online cryotrapping were used to measure ammonia or chlorine, as well as other unwanted odorants, emanating from bulk AN, UN, and PC in TADDs over 28 weeks. The analytical data showed variation in the amount of ammonia and chlorine over time, with ammonia from AN and UN decreasing slowly over time and the abundance of chlorine from PC TADDs dependent on the frequency of exposure to ambient air. Even with these variations in odor abundance, canines previously trained to detect bulk explosive HME components were able to detect all three targets in glass and plastic TADDs for at least 18 months after loading. Detection proficiency ranged from 64% to 100% and was not found to be dependent on either age of material.  相似文献   
45.
The onus of proof in criminal cases is beyond any reasonable doubt, and the issue on the lack of complete internal validation data can be manipulated when it comes to justifying the validity and reliability of the X-chromosomal short tandem repeats analysis for court representation. Therefore, this research evaluated the efficiency of the optimized 60% reduced volumes for polymerase chain reaction (PCR) amplification using the Qiagen Investigator® Argus X-12 QS Kit, as well as the capillary electrophoresis (CE) sample preparation for blood samples on Flinder's Technology Associates (FTA) cards. Good-quality DNA profile (3000–12,000 RFU) from the purified blood sample on FTA card (1.2 mm) were obtained using the optimized PCR (10.0 μL of PCR reaction volume and 21 cycles) and CE (9.0 μL Hi-Di™ Formamide and 0.3 μL DNA Size Standard 550 [BTO] and 27 s injection time) conditions. The analytical and stochastic thresholds were 100 and 200 RFU, respectively. Hence, the internal validation data supported the use of the optimized 60% reduced PCR amplification reaction volume of the Qiagen Investigator® Argus X-12 QS Kit as well as the CE sample preparation for producing reliable DNA profiles that comply with the quality assurance standards for forensic DNA testing laboratories, while optimizing the analytical cost.  相似文献   
46.
The storage and use of explosives is regulated at the state and federal level, with a particular focus on physical security and rigorous accounting of the explosive inventory. For those working with explosives for the training and testing of explosive-detecting canines, cross-contamination is an important concern. Hence, explosives intended for use with canine teams must be placed into secondary storage containers that are new, clean, and airtight. A variety of containers meet these requirements and include screw-top glass jars (e.g., mason jars). However, an additional need from the explosive-detecting canine community is secondary containers that can also be used as training aids whereby the volatiles emitted by explosives are emitted in a predictable and stable manner. Currently, a generally accepted method for the storage of explosives and controlled emission of explosive vapor for canine detection does not exist. Ideally, such containers should allow odor to escape from the training aid but block external contaminates such as particulates or other volatiles. One method in use places the explosive inside a permeable cotton bag when in use for training and then stores the cotton bag inside an impermeable nylon bag for long-term storage. This paper describes the testing of an odor permeable membrane device (OPMD) as a new way to store and deploy training aids. We measured the evaporation rate and flux of various liquid explosives and volatile compounds that have been identified in the headspace of actual explosives. OPMDs were used in addition to traditional storage containers to monitor the contamination and degradation of 14 explosives used as canine training aids. Explosives were stored individually using traditional storage bags or inside an OPMD at two locations, one of which actively used the training aids. Samples from each storage type at both locations were collected at 0, 3, 6, and 9 months and analyzed using Fourier Transform Infrared (FTIR) Spectroscopy and Gas Chromatography–Mass Spectrometry (GC–MS) with Solid-Phase Microextraction (SPME). FTIR analyses showed no signs of degradation. GC–MS identified cross-contamination from ethylene glycol dinitrate (EGDN) and/or 2,3-dimethyl-2,3-dinitrobutane (DMNB) across almost all samples regardless of storage condition. The contamination was found to be higher among training aids that were stored in traditional ways and that were in active use by canine teams.  相似文献   
47.
Recently, digital forensics has become increasingly important as it is used by investigation agencies, corporate, and private sector. To supplement the limitations of evidence capacity and be recognized in court, it is essential to establish an environment that ensures the integrity of the entire process ranging from collecting and analyzing to submitting digital evidence to court. In this study, common elements were extracted by comparing and analyzing ISO/IEC 17025, 27001 standards and Interpol and Council of Europe (CoE) guidelines to derive the necessary components for building a digital forensic laboratory. Subsequently, based on 21 digital forensic experts in the field, Delphi survey and verifications were conducted in three rounds. As a result, 40 components from seven areas were derived. The research results are based on the establishment, operation, management, and authentication of a digital forensics laboratory suitable for the domestic environment, with added credibility through collection of the opinions of 21 experts in the field of digital forensics in Korea. This study can be referred to in establishing digital forensic laboratories in national, public, and private digital forensic organizations as well as for employing as competency measurement criteria in courts to evaluate the reliability of the analysis results.  相似文献   
48.
This work presents a data survey regarding the qualitative chemical analysis of drugs seized by the Police in the state of Minas Gerais between July 2017 and June 2022, including an evaluation of labeling of 265 samples of anabolic androgenic steroids (AAS) seized in 2020. The Active Pharmaceutical Ingredients (API) present in the samples were identified through chemical analysis and classified by system Anatomical Therapeutic Chemical (ATC) methods. Analysis of the labeling information for 265 samples of AAS followed the guidance of legislation RDC 71 (2009) from ANVISA. For this study 6355 seized pharmaceuticals underwent qualitative chemical analysis that corresponded to 7739 APIs successfully identified and classified. Among the components studied AAS, psychostimulants, anesthetics, and analgesics were the most commonly examined. AAS seized and tested increased by over 100% and for the majority of the samples analyzed were found to not match the labeling on the packaging. In the meantime, anti-obesity drugs presented a prominent increase of 400% from 2020/1 to 2021/2, during covid-19 quarantine. Seized pharmaceuticals and tests can support information in the planning of public health and safety policies.  相似文献   
49.
Human hairs are one of the most commonly encountered items of trace evidence. Currently, conventional methods for hair analysis include microscopic comparison and DNA analysis (nuclear and mitochondrial). Each approach has its own drawbacks. Hair proteins are stable and offer an alternative to DNA testing, as demonstrated with proteomics for distinguishing humans. However, proteomics is complicated and requires identifying peptides to remain intact following harsh sample preparation methods. Alternatively, the actual amino acid content of a hair sample may also offer important identifying information and actually requires proteins and peptides to be broken down completely rather than remaining intact. This study evaluated the discriminating power of using hair amino acid ratios to differentiate hair samples from 10 unrelated individuals with dark colored hair. Hair proteins were digested, derivatized, and analyzed using gas chromatography–mass spectrometry. Amino acid ratios were calculated for each individual and comparisons using ANOVA and post-hoc pairwise t-test with Bonferroni correction were made with amino acid ratios for individuals. Overall, out of the 45 possible pairwise comparisons between all hair samples, 38 (84%) were differentiable. Out of the 36 possible pairwise comparisons between brown haired individuals, 32 (89%) were considered differentiable using univariate statistics. Multivariate statistics were also attempted but, overall, univariate models were sufficient for exclusionary purposes. These results indicate that amino acid ratio analysis can potentially be used as an exclusionary method using hair if DNA analysis cannot be performed, or to corroborate conclusions made following microscopic analysis.  相似文献   
50.
Illicit fentanyl has flooded the United States' drug market, increasing the risk of overdose and poisonings throughout the general population and accidental exposure among law enforcement officers confiscating the increasing number of seizures. Fentanyl test strips (FTS) are used to obtain presumptive information about the presence of fentanyl in a suspected sample. However, their adoption by law enforcement personnel and seized-drug analysts has been limited because most products are advertised for urine testing, not for assays using water solutions. This study presents an evaluation of four commercial FTS: Rapid Response from BTNX, Inc.; T-Dip Fentanyl (FTY) Urine Dip Cards obtained from Amazon.com ; Premier BioDip FYL10 from Premier Biotech Inc.; and MobileDetect Fentanyl strips from DetectaChem, Inc. Performance characteristics curves were used to compare the products' sensitivity, showing that all can reliably detect fentanyl in aqueous solutions at concentrations below 1 μg/mL, with some of the tests able to reliably detect the drug at 200 ng/mL. A stability study demonstrates the performance of all four FTS brands was only slightly affected after 30 days of storage at two extreme environmental conditions. Fentanyl-related substances are also evaluated using the Rapid Response FTS, which showed high cross-reactivity with para-fluorofentanyl and acetylfentanyl, but lower with ortho-chlorofentanyl, carfentanil, and 4-ANPP. Users should be aware that FTS may give false-negative results even when potentially dangerous levels of carfentanil are present. When testing other common drugs, adulterants, and diluents frequently encountered in seized tablets, concentration-dependent results were obtained and multiple instances of false positives were recorded.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号