首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Contamination of canine training aids is a pervasive issue that may lead to incorrect canine discrimination of target odors. It is therefore important to properly store training materials to maintain their integrity and efficiency. First, this study demonstrated the potential for contamination using GloGerm™ as a proxy for odor/particulate transfer. Then, eight types of containers were evaluated to determine (1) the ability to prevent odor permeation and (2) the likelihood of maintaining the ab/adsorbed odor. Lastly, a longitudinal study evaluated how the permeation of the target odor changed over time. Analysis occurred using a direct analysis in real-time mass spectrometer (DART-MS) to detect triacetone triperoxide (TATP) from the non-hazardous canine training aid known as the polymer odor capture-and-release (POCR) system. Results showed that Mylar and Opsak bags were most effective for short-term storage, maintaining low levels of ab/adsorption. Over time, the amount of TATP permeating through the primary containers and collecting in a secondary container (i.e., outer packaging) increased at 1 week and decreased thereafter (up to 4 months). The amount of TATP collecting in the primary containers, however, increased up to 1 month and decreased thereafter.  相似文献   

2.
While canines are most commonly trained to detect traditional explosives, such as nitroaromatics and smokeless powders, homemade explosives (HMEs), such as fuel–oxidizer mixtures, are arguably a greater threat. As such, it is imperative that canines are sufficiently trained in the detection of such HMEs. The training aid delivery device (TADD) is a primary containment device that has been used to house HMEs and HME components for canine detection training purposes. This research assesses the odor release from HME components, ammonium nitrate (AN), urea nitrate (UN), and potassium chlorate (PC), housed in TADDs. Canine odor recognition tests (ORTs) were used with analytical data to determine the detectability of TADDs containing AN, UN, or PC. Headspace analysis by gas chromatography/mass spectrometry (GC/MS) with solid-phase microextraction (SPME) or online cryotrapping were used to measure ammonia or chlorine, as well as other unwanted odorants, emanating from bulk AN, UN, and PC in TADDs over 28 weeks. The analytical data showed variation in the amount of ammonia and chlorine over time, with ammonia from AN and UN decreasing slowly over time and the abundance of chlorine from PC TADDs dependent on the frequency of exposure to ambient air. Even with these variations in odor abundance, canines previously trained to detect bulk explosive HME components were able to detect all three targets in glass and plastic TADDs for at least 18 months after loading. Detection proficiency ranged from 64% to 100% and was not found to be dependent on either age of material.  相似文献   

3.
Human remains detection (HRD) canines are trained to locate human remains in a variety of locations and situations which include minimal quantities of remains that may be buried, submerged or extremely old. The aptitude of HRD canines is affected by factors such as training, familiarity with the scent source and environmental conditions. Access to appropriate training aids is a common issue among HRD canine handlers due to overly legal restrictions, difficulty in access and storage, and the potential biological hazards stemming from the use of actual human remains as training aids. For this reason, we propose a unique approach of training aid creation, utilizing non-contact, dynamic air-flow odor concentration onto sorbent materials. Following concentration, the sorbent material retains the odor from the scent source composed of volatile organic compounds. The sorbent material containing the odor can then be utilized as a canine training aid. Training materials prepared in this manner were tested under a variety of conditions with many HRD canines to demonstrate the efficacy of the new training aids. A high level of correct canine responses to the new training aids was achieved, approaching 90%, with minimal false positives.  相似文献   

4.
It is a common misconception that the amount of explosive is the chief contributor to the quantity of vapor that is available to trained canines. In fact, this quantity (known as odor availability) depends not only on the amount of explosive material, but also the container volume, explosive vapor pressure and temperature. In order to better understand odor availability, headspace experiments were conducted and the results were compared to theory. The vapor-phase concentrations of three liquid explosives (nitromethane, nitroethane and nitropropane) were predicted using the Ideal Gas Law for containers of various volumes that are in use for canine testing. These predictions were verified through experiments that varied the amount of sample, the container size, and the temperature. These results demonstrated that the amount of sample that is needed to saturate different sized containers is small, predictable and agrees well with theory. In general, and as expected, once the headspace of a container is saturated, any subsequent increase in sample volume will not result in the release of more vapors. The ability of canines to recognize and alert to differing amounts of nitromethane has also been studied. In particular, it was found that the response of trained canines is independent of the amount of nitromethane present, provided it is a sufficient quantity to saturate the container in which it is held.  相似文献   

5.
Fire debris evidence may contain ignitable liquid residues valuable in the investigation of a potential arson scene. The ability to obtain evidence containers that are contaminant-free and vapor-tight is essential to the analysis and storage of fire debris evidence. Commercial containers such as metal "paint" cans, glass mason jars, and polymer bags are often employed as fire debris evidence containers. The purpose of this research was to determine which of these three types of containers provided the most vapor-tight seal for the prevention of ignitable liquid vapor loss and to assess the potential for cross-contamination. Leak rates for each type of container were measured under controlled conditions. Simple mixtures of hydrocarbons were utilized in these experiments. Leak rates were determined based on the amounts of hydrocarbon recovered from activated charcoal located outside the test container and within a secondary container. Quantitation of the hydrocarbons recovered from activated charcoal was calculated using external standard calibration curves following analysis by gas chromatography-mass spectrometry. The results demonstrated that glass jars had the fastest leak rate followed by metal paint cans and properly heat-sealed polymer bags with the slowest leak rate. Each container exhibited a different leak mechanism, which resulted in an observable effect on the composition of hydrocarbons lost from the container. Hydrocarbon transfer from one container to another is also demonstrated. This study presents results that reveal the most vapor-tight container to be a properly heat-sealed copolymer bag.  相似文献   

6.
Despite numerous instrumental achievements, canines are still considered the most effective field method for explosive detection. However, due to strict explosive regulations and safety requirements, it can be a challenge for agencies with "bomb dogs" to train using neat explosive materials. This establishes a need for non-explosive canine training aids with the same volatile component profiles as the explosives that they represent. In order to compare mimic materials to their explosive counterparts, a technique must be established that not only allows for identification of volatile compounds but also can monitor changes in the headspace profile over time with respect to time and temperature. The Automated Training Aid Simulation using SPME (or ATASS) was developed for that purpose. As described, ATASS was used to observe changes in the volatile profile of three explosives (Composition C-4, 2,4-dinitrotoluene (DNT), and triacetone triperoxide (TATP)) and respective prototype training materials (0.1% by mass C-4, 1% by mass 2,4-DNT, and 1% by mass TATP). Samples were prepared in vials and metal tins within a gallon (≈ 3785 mL) paint can to simulate common field techniques for canine training. Monitoring these materials in real time provides a better understanding of the major volatile components present and how the relative abundances of these components can change over time. The results presented indicate that ATASS successfully allows for a sufficient comparison between explosive and non-explosive training materials.  相似文献   

7.
The purpose of this work was to study the appropriateness of polyethylene bags for the preservation of explosive specimens. To this end, specimens of two types of dynamites, Goma-2 EC, containing nitroglycol (EGDN) and dinitrotoluene (DNT), and Goma-2 ECO, containing only EGDN, were placed individually inside bags and introduced into hermetically sealed glass jars, which were stored for a period of time. Losses of volatile compounds were studied by headspace analysis using gas chromatography coupled to mass spectrometry (GC-MS). The cross-contamination between dynamites was studied by using high performance liquid chromatography with mass spectrometry (HPLC-MS) to analyse the extracts obtained after a sequential solvent extraction of these specimens. Polyethylene bags permit the loss of volatile compounds since EGDN and DNT were detected in the headspaces of the jars. Moreover, cross-contamination between dynamites was also demonstrated since DNT content decreased in the dynamite containing this compound and increased in the dynamite that had not contained it.  相似文献   

8.
This study sought to assign a rough order of magnitude for the amount of explosive residue likely to be available in real-world searches for clandestine explosives. A variety of explosives (TNT, TATP, HMX, AN, RDX, PETN) in various forms (powder, flake, detonating cord, plastic) were carefully weighed or cut into containers, and the amount of residue inadvertently remaining on the work area, hands, or containers was quantified. This was used to evaluate the spillage potential of each explosive. The adhesion of each explosive to a glass surface was quantified from amount of explosive adhering to the inside of a glass vial into which the explosive had been placed and then removed by vigorous tapping. In powdered form, most of the explosives--TNT, PETN, RDX, HMX, and TATP--exhibited similar spillage and adhesion to glass. However, PETN as sheet explosive and plasticized RDX (C-4), showed very little potential to contaminate surfaces, either by spillage or adhesion to glass.  相似文献   

9.
《Science & justice》2022,62(5):657-665
Canines trained on scents from materials emitting vapours of explosives and related compounds are widely used to detect explosives in civilian, military and forensic applications. Despite the importance of these training materials, there is limited knowledge on how long these subsamples can be stored and whether vapour profiles change over time. We developed a sampling methodology that makes use of a secondary chamber for stabilisation of headspace concentration to allow reliable and reproducible determination of scent profiles. The effect of aging was investigated by following the response of volatile markers emitted from eight common explosives in open and closed containers over two months or two years. The initial headspace air volume consisted of a wide variety of chemical substances related to explosives, with levels varying in magnitude from low ppb to ppm. All included subsamples were affected by aging by demonstrating exponentially lower levels, and five subsamples showed a significant change in their scent profile. The dominant components decreased on a short time scale for plastic explosives based on RDX, PETN and dynamite as well as for granules of octol and ammonium nitrate mixed with fuel. For flakes of TNT, granules of Comp B and nitrocellulose powder, headspace air concentrations declined, but the overall character of their profiles were in general more stable. The overall changes, i.e., lower levels and/or changed profiles, justifies regular checks of the scent status of training materials. Considering these results together with data displaying marginal changes in energetic performance, it is advisable to complement scent training with training materials subjected to different durations of aging.  相似文献   

10.
The efficiency of solvent based extraction methods used to remove explosive residues from four different swab types was investigated. Known amounts of organic and inorganic residues were spiked onto a swab surface with acetonitrile or ethanol:water combined with ultrasonication or physical manipulation used to extract the residues from each swab. The efficiency of each procedure was then calculated using liquid chromatography‐ultraviolet detection for organic residues and ion chromatography for inorganic residues. Results indicated that acetonitrile combined with physical agitation proved to be the most efficient method; returning analyte recoveries c. 95% for both alcohol based swabs and cotton balls. Inorganic residues were efficiently extracted using ethanol:water, while the use of acetonitrile followed by water significantly reduced the recovery of inorganic residues. Swab storage conditions were then investigated with results indicating decreased storage temperatures are required to retain the more volatile explosives.  相似文献   

11.
This study examines the sorption of eight explosives (2,4,6-trinitrotoluene [TNT]; pentaerythritol tetranitrate [PETN]; hexahydro-1,3,5-trinitro-s-triazine [RDX]; diacetone diperoxide [DADP]; triacetone triperoxide [TATP]; ethylene glycol [EGDN], nitroglycerin [NG]; and 2,4-dinitrotoluene [DNT]) to human hair. The study uses only cut hair, which is exposed to explosive vapor. The vapor transfer studies reported herein indicated that hair did not reach saturation even after 2.5 years of exposure to TNT. While previous studies showed black hair sorbed more explosive than blond or brown, this study reports that red hair sorption is similar to black, while grey hairs, exposed along with black hair from the same individual, sorbed significantly less explosive than the same individual's black hairs. In a study using only black hair, a slight racial bias was observed with sorption greater for Mongoloid hair as compared to Caucasian or Negroid. Only for Mongoloid hairs were enough samples studied to examine for a gender bias, but one was not observed. There was much variability in results in all categories (hair color, race, and gender) that trends were established only in general terms. Hair at different ages was tested for a few individuals. Detailed studies focused on the sorption of TATP and TNT as these appear to be sorbed most differently-TATP mainly on the hair surface and TNT both on the surface and in the cortex. The uptake of high vapor pressure explosives (e.g., TATP) and moderate vapor pressure explosives (e.g., TNT) by hair was rapid and could be detected within about 1 h of exposure. Both explosives were readily sorbed by pure melanin.  相似文献   

12.
The tsunami catastrophe of December 2004 left more than 200,000 dead. Disaster victim identification (DVI) teams were presented with the unprecedented challenge of identifying thousands of mostly markedly putrefied and partially skeletised bodies. To this end, an adequate body tagging method is essential. Conventional body bag tagging in terms of writing on body bags and placing of tags inside body bags proved unsatisfactory and problem prone due to consequences of cold storage, formalin (formaldehyde) embalming and body numbers inside storage facilities. The placement of radio frequency identification device (RFID) microchips inside victim bodies provided a practical solution to problems of body tagging and attribution in the DVI setting encountered by the Austrian DVI team in Thailand in early 2005.  相似文献   

13.
The aim of this study was to compare seized samples of 3,4-methylenedioxy-N-methylamphetamine (MDMA) pills, used to train law enforcement detection canine teams, to determine what differences exist in the chemical makeup and headspace odor and their effect on detectability. MDMA solutions were analyzed by liquid chromatography-mass spectrometry. Analysis of these samples showed a wide variance of MDMA (8-25%). Headspace SPME-GC/MS analysis showed that several compounds such as 3,4-methylenedioxyphenylacetone and 1-(3,4-methylenedioxyphenyl)-2-propanol are common among these MDMA samples regardless of starting compound and synthesis procedure. However, differences, such as the level of the various methylenedioxy starting compounds, were shown to affect the overall outcome of canine detection, indicating the need for more than one MDMA training aid. Combinations of compounds such as the primary odor piperonal in conjunction with a secondary compound such as MDP-2-OH or isosafrole are recommended to maximize detection of different illicit MDMA samples.  相似文献   

14.
Abstract: Fire debris evidence is collected and stored in a wide range of containers, including various polymer bags. Four different polymer bags have been investigated, including the NYLON, DUO, ALU, and AMPAC bags. The latter is the successor of the Kapak Fire DebrisPAK?. Microscopy and infrared spectroscopy were used to elucidate the composition of the bags. Gas chromatography/mass spectrometry was used to investigate performance parameters such as background volatiles, leak rate, cross‐contamination, recovery, and sorption. The NYLON bag was susceptible for leakage and cross‐contamination and showed decreased recoveries. The DUO and ALU bags showed some background volatiles, sorption, and poor recoveries. The AMPAC bag performed excellent: low background, no leakage or cross‐contamination, good recoveries, and only traces of sorption. Heat sealing proved to be the best method of closure. Preliminary studies on AMPAC bags showed that polyethylene clamps are easy to use on‐site and preserve ignitable liquids adequately for a limited period of time.  相似文献   

15.
Traditional methods of volatile detection used by police typically consist of reliance on canine olfaction. However, dogs have some limitations such as cost of training and time of conditioning. The possibility of using parasitic wasps for detecting explosives and narcotics has been developed. Moreover, wasps are cheap to produce and can be conditioned with impressive speed for a specific chemical detection task. We examined the ability of Nasonia vitripennis Walker to learn and respond to methyldisulfanylmethane (DMDS), a volatile discriminator of cadaver. The training aimed to form an association between an unconditioned stimulus (pupae) and the conditioned stimulus (odor source). After the training, the time spent by conditioned wasps in the DMDS chamber was measured. Statistical analysis showed that the increasing concentrations involved an increase in the time spent in the chamber containing DMDS. This study indicates that N. vitripennis can respond to DMDS, which provide further support for its development as a biological sensor.  相似文献   

16.
Apprehending those who utilize improvised explosive devices (IEDs) is a national priority owing to their use both domestically and abroad. IEDs are often concealed in bags, boxes, or backpacks to prevent their detection. Given this, the goal of the research presented was to identify IED handlers through postblast DNA recovery from IED containers. Study participants were asked to use backpacks for 11 days, after which they served as containers for pipe bombs. Eleven postdeflagration backpack regions likely to be handled were swabbed and analyzed via mini-short tandem repeats (miniSTRs) and alleles were called blind. An experimental consensus method was examined in which profiles from all regions were considered, to help identify spurious drop-in/out. Results were correct for all loci, except one that remained ambiguous. The results show that recovering DNA from IED containers is a viable approach for aiding in the identification of those who may have been involved in an IED event.  相似文献   

17.
The ability of two mass spectrometric methods, surface-assisted laser desorption/ionization-time of flight-mass spectrometry (SALDI-TOF-MS) and direct analysis in real time (DART-MS), to detect the presence of seven common explosives (six nitro-organic- and one peroxide-type) in spiked latent fingermarks has been examined. It was found that each explosive could be detected with nanogram sensitivity for marks resulting from direct finger contact with a glass probe by DART-MS or onto stainless steel target plates using SALDI-TOF-MS for marks pre-dusted with one type of commercial black magnetic powder. These explosives also could be detected in latent marks lifted from six common surfaces (paper, plastic bag, metal drinks can, wood laminate, adhesive tape and white ceramic tile) whereas no explosive could be detected in equivalent pre-dusted marks on the surface of a commercial lifting tape by the DART-MS method due to high background interference from the tape material. The presence of TNT and Tetryl could be detected in pre-dusted latent fingermarks on a commercial lifting tape for up to 29 days sealed and stored under ambient conditions.  相似文献   

18.
Research to counter the threat of organic peroxides such as triacetone triperoxide (TATP) is at times hampered by their inherent extreme sensitiveness and volatility. This work describes an approach to lowering some risks associated with the handling of TATP in the laboratory through the use of an analog species, tripentanone triperoxide (TPTP). Sensitiveness has been tested via standard methods. GCMS analysis has shown that TPTP degrades via similar mechanisms to TATP under a range of conditions. Slight differences in product composition were traced to side reactions which may also affect impurities present in homemade TATP synthesis. A pilot field trial was conducted to evaluate TPTP as a substitute for TATP in explosive detection dog (EDD) scent training. The degradation studies have yielded insights into the complexities of the acidic degradation of cyclic peroxides with potential forensic application, and TPTP's inadequacy as a TATP pseudoscent is a valuable example of the limitations of such training aids.  相似文献   

19.
It is important to understand the extent of transfer of explosive particles to different surfaces in order to better evaluate potential cross-contamination by explosives in crowded security controls such as those at airports. This work investigated the transfer of nine explosive residues (ANFO, dynamite, black powder, TNT, HMTD, PETN, NH4NO3, KNO3, NaClO3) through fingerprints from one surface to another. First, the extent of adhesion of explosive residues from different surfaces to the bare finger, nitrile and latex gloves was studied. Then, the transfer of explosive residues from one surface to another through fingerprints was investigated. Cotton fabric (hereinafter referred to as cotton) as clothing material and polycarbonate plastic (hereinafter referred to as polycarbonate) as luggage material were chosen for the experiments. These surfaces containing explosive particles were imaged using a reflex camera before and after the particles were transferred. Afterwards the images were processed in MATLAB where pixels corresponding to explosive residues were quantified. Results demonstrated that transfer of explosive residues frequently occurred with certain differences among materials. Generally, the amount of explosive particles adhered to the finger decreased in the following order: skin>latex>nitrile, while the transfer of particles from the finger to another surface was the opposite. The adhesion of explosive residues from polycarbonate to the finger was found to be better compared to cotton, while the amount of particles transferred to cotton was higher.  相似文献   

20.
《Science & justice》2021,61(6):697-703
The identification and confirmation of trace explosive residues along with potential precursors and degradation products require a comprehensive laboratory analysis procedure. This study presents the determination of organic explosives consisting of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT), 2,4,6,N-tetranitro-N-methylaniline (Tetryl), 1,3,5-trinitrobenzene (1,3,5-TNB) and pentaerythritol tetranitrate (PETN) by a high-resolution liquid chromatography quadrupole time-of-flight mass spectrometry (LC−QTOF/MS). The qualitative information including retention time, collision energy, precursor ions, and characteristic fragmentation pattern of each explosive were collected using an atmospheric pressure chemical ionization (APCI) in negative ion mode. The separation efficiency among five compounds was greatly achieved in this study. Four real explosive samples consisting of TNT, RDX, PETN and Tetryl and 12 Ionscan® quality control swabs from the Royal Thai Army were also tested to validate and verify the viability of the GC–MS method used to validate results from an Ionscan® system. The results showed that LC−QTOF/MS is a powerful technique for the identification and confirmation of thermally unstable organic explosives on Ionscan® swabs compared to a conventional GC−MS technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号