全文获取类型
收费全文 | 272篇 |
免费 | 36篇 |
专业分类
工人农民 | 1篇 |
法律 | 233篇 |
中国共产党 | 3篇 |
中国政治 | 21篇 |
政治理论 | 4篇 |
综合类 | 46篇 |
出版年
2024年 | 4篇 |
2023年 | 7篇 |
2022年 | 2篇 |
2021年 | 10篇 |
2020年 | 13篇 |
2019年 | 7篇 |
2018年 | 7篇 |
2017年 | 7篇 |
2016年 | 10篇 |
2015年 | 11篇 |
2014年 | 21篇 |
2013年 | 26篇 |
2012年 | 12篇 |
2011年 | 24篇 |
2010年 | 18篇 |
2009年 | 17篇 |
2008年 | 25篇 |
2007年 | 24篇 |
2006年 | 18篇 |
2005年 | 9篇 |
2004年 | 6篇 |
2003年 | 10篇 |
2002年 | 8篇 |
2001年 | 4篇 |
2000年 | 5篇 |
1999年 | 1篇 |
1996年 | 1篇 |
1985年 | 1篇 |
排序方式: 共有308条查询结果,搜索用时 15 毫秒
51.
Suspects in shooting investigations in Chicago are routinely transported in department vehicles and detained in department facilities prior to gunshot residue (GSR) evidence collection. The GSR test results are used to associate the suspect with primary exposure to GSR. The potential for these vehicles and facilities being sources of secondary GSR contamination needed to be determined. A total of 201 samples were collected from randomly selected vehicles and detention facilities. The sampling collected trace materials from surfaces that suspects' hands may contact during the arrest process. These samples were examined for the presence of GSR particles using scanning electron microscopy. Upon completion of the automated analysis, those particles that met an initial GSR screening criterion were relocated and reanalyzed. The locations where GSR particles were recovered allowed us to make recommendations to the Chicago Police Department with regard to transporting and detaining these suspects. The low number of GSR particles recovered suggests that the potential for secondary contamination, although present, is relatively low. 相似文献
52.
Robert G. Weston M.Sc. 《Journal of forensic sciences》2010,55(4):1068-1075
Abstract: The analysis of mixtures of “crystal meth” (usually comprised of methyl sulfone [MS] and methamphetamine [MA]) by gas chromatography‐mass spectrometry (GCMS) is routine in many forensic drug laboratories. The utilization of Raman spectroscopy for the identification of such mixtures quickly and without the need for a separation technique is discussed. Samples were dissolved in water and Raman spectra of the resulting aqueous solutions were collected. By comparing these spectra to spectra of methylsulfone and MA mixtures of known composition, an indication of the composition of the sample can be obtained in only a few minutes. This spectral comparison also can be used as a semi‐quantitative analysis of MA concentrations in such exhibits. 相似文献
53.
Kelly M. Brinsko M.S. 《Journal of forensic sciences》2010,55(4):915-923
Abstract: Fibers that are termed “eco‐friendly” or “biodegradable” by manufacturers are increasingly being used in textile products such as apparel and carpeting to appeal to the ever more environmentally aware public. As such, these modern fibers are expected to begin showing up more often in forensic casework, and it is important that the forensic examiner recognize them. This study employed polarized light microscopy (PLM) and Fourier transform infrared (FTIR) microspectroscopy to characterize selected fibers of azlon, polylactic acid (PLA), cellulose composites of alginate or chitin, and bamboo (viscose rayon). Fiber cross‐sections, refractive indices, melting points, solubilities, and FTIR measurements were conducted. Results indicate that the azlons and PLA fibers are easily distinguishable from other textile fibers by their optical and chemical properties. The cellulose composites show only small differences in comparison with other cellulose‐based fibers, while bamboo viscose rayon is indistinguishable from normal viscose rayon. 相似文献
54.
Norimitsu Akiba Ph.D. Kenro Kuroki Ph.D. Kenji Kurosawa Ph.D. Ken'ichi Tsuchiya Ph.D. 《Journal of forensic sciences》2018,63(2):556-562
Detection of aged fingerprints is difficult because they can degrade over time with exposure to light, moisture, and temperature. In this study, aging fingerprints were visualized by time‐resolved spectroscopy with an ultraviolet‐pulsed laser. Fingerprints were prepared on glass slides and paper and then stored under three lighting conditions and two humidity conditions for up to a year. The fluorescence intensities of the fingerprints decreased with time. Samples were stored in the dark degraded less than in sunlight or under a fluorescent lamp. Samples were stored under low humidity degraded less than under moderate humidity. As the storage period increased, a fluorescence emission peak appeared that was at a longer wavelength than the peak visible in earlier spectra. This peak was used for visualization of an aged fingerprint over time. An image of the fingerprint was not initially visible, but an image appeared as the time since deposition of the fingerprint increased. 相似文献
55.
Controversial Suicide Case Using a Submachine Gun with a Sound Suppressor—The Need of Team Work of Forensic Chemistry and Firearm Examiners 下载免费PDF全文
Zuzanna Brożek‐Mucha Ph.D. Krzysztof Zdeb M.Sc. Eng. 《Journal of forensic sciences》2018,63(3):921-929
Evidence materials in a presumed suicide case were studied by a firearm examiner and a forensic chemist. The victim's body with double gunshot wounding in his forehead, a machine gun in the sustained fire mode with a silencer, and four cartridge cases were found. Examinations of the evidence, the case file studies, and experiments dedicated to the case were carried out. Relationships between the placement of cartridge cases and the gun were established using a fast camera. The distributions of gunshot residues on the evidence materials and within the comparative gunshot patterns were studied by means of optical and electron microscopy, X‐ray microanalysis, and infrared spectroscopy. The shooting distance was assessed to be 30 cm or more, whereas the greatest distance that could have been achieved by the victim himself was about 11–13 cm. The obtained results supported the version of homicide rather than suicide. 相似文献
56.
Diana M. Wright Ph.D. Maureen J. Bradley Ph.D. Andria Hobbs Mehltretter M.S. 《Journal of forensic sciences》2013,58(2):358-364
Comparative analyses of 50 single‐layer white architectural paints were conducted to determine the discrimination power using standard techniques and to provide a basis for assessing significance when paints with limited features are not discriminated. Utilizing Fourier transform infrared spectroscopy (FTIR), 68 undifferentiated pairs resulted, yielding a discrimination of 94.45%. Adding stereomicroscopy, scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) and backscatter electron (BSE) imaging, and pyrolysis‐gas chromatography/mass spectrometry (Py‐GC/MS), the overall discrimination was 99.35%. The study included blind verification replicates, which resulted in the only pairs without indications of physical or chemical differences. The remaining groups of undifferentiated samples contained subtle differences by at least one technique, but were considered undifferentiated for the discrimination power evaluations. This study demonstrates a high degree of discrimination of single‐layer white architectural paints using methods of analysis often encountered in forensic science laboratories. 相似文献
57.
Jeremy S. Triplett M.Sc. Jennifer A. Hatfield M.Sc. Tracy L. Kaeff B.Sc. Christopher R. Ramsey B.Sc. Susan D. Robinson B.Sc. Allison F. Standifer M.Sc. 《Journal of forensic sciences》2013,58(6):1607-1614
Raman spectroscopy has found increased use in the forensic controlled substances laboratory in recent years due to its rapid and nondestructive analysis capabilities. Here, Raman spectroscopy as a screening test for methamphetamine in clandestine laboratory liquid samples is discussed as a way to improve the efficiency of a laboratory by identifying the most probative samples for further workup among multiple samples submitted for analysis. Solutions of methamphetamine in ethanol, diethyl ether, and Coleman fuel were prepared in concentrations ranging from 0.5% to 10% w/v, and Raman spectra of each were collected. A concentration‐dependant Raman peak was observed at 1003 per cm in each solution in 4% w/v and greater solutions. Case samples were analyzed and also found to reliably contain this diagnostic peak when methamphetamine was present. The use of this diagnostic indicator can save the forensic controlled substances laboratory time and materials when analyzing clandestine laboratory liquid submissions. 相似文献
58.
Sunlin Hu Ph.D. ; Hui Shen Ph.D. ; Songcai Wang B.S. ; Chao Fang M.D. 《Journal of forensic sciences》2009,54(6):1349-1352
Abstract: A young male was shot to death by a police officer with a Chinese Type 64 7.62 mm pistol when he was dealing with an aggravated assault arising from a traffic accident. By using scanning electron microscopy and energy dispersive X-ray spectroscopy (SEM/EDX), trace deposits on the discharged bullet and the intermediate target, i.e., a concrete telegraph pole at the scene, were identified to be from each other. The result demonstrated the bullet causing the death ricocheted from the concrete telegraph pole before striking the victim, thus indicating the incident was accidental. The case report illustrates the evidential value of trace materials derived, respectively, from discharged bullets and intermediate targets in bullet–intermediate target interaction for trajectory reconstruction. In addition, it indicates that the SEM/EDX method with its nondestructive nature, compared to other methods, may be more helpful in certain situations in determining the origins of trace evidentially valuable deposits on substrates. 相似文献
59.
Marija Jakubeniene Algimantas Irnius Gregoire Abi Chaker Jonas Mindaugas Paliulis Antanas Bechelis 《Forensic Science International Supplement Series》2009,190(1-3):87-90
The identification of hypothermia as cause of the death was always quite problematic in the field of forensic medicine. The aim of the present study was to verify the determination of calcium content in post-mortem liver, heart, and skeletal muscle samples as the biochemical marker defining hypothermia as the cause of death. The study involved 43 autopsy cases in which the circumstances of death indicated the effects of overcooling. The control group consisted of material collected from the corpses of 30 persons who were not exposed to low temperatures but died due to technical injuries (n = 5), asphyxia (n = 6), intoxication with ethanol and other substances (n = 8), and acute myocardial infarction/ischemia (n = 11). The concentration of calcium in autopsy samples was determined applying flame atomic absorption spectroscopy. Our study showed no significant differences of calcium content in tissues of persons who died due to hypothermia, over those who died in normothermic conditions. 相似文献
60.
在文件检验中,黑白红外线照相是一种检验变造文件的方法,然而,在某些情况下效果欠佳。为了提高检验的准确性,不妨可以应用红外线合成图像的方法。应用Photoshop图像处理方法,根据红外线彩色照相的感光原理和色彩再现过程,对数码照相机拍摄的可见光图像和红外线图像进行适当处理,即可生成红外线合成图像。这种图像可以反映字迹对可见光和红外线的吸收与反射情况,通过判断字迹颜色有否改变来检验书写色料的异同。由此可见,利用红外线合成图像方法检验某些变造文件,可以获得黑白红外线照相无法得到的检验结果,这对提高鉴定结论的准确性具有实际应用价值。 相似文献