首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   27篇
  免费   1篇
工人农民   1篇
世界政治   1篇
外交国际关系   2篇
法律   22篇
政治理论   2篇
  2017年   2篇
  2016年   1篇
  2015年   1篇
  2013年   3篇
  2007年   4篇
  2005年   2篇
  2003年   1篇
  2001年   2篇
  1992年   2篇
  1989年   4篇
  1988年   3篇
  1987年   1篇
  1986年   2篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
Fatal intoxications in the 15-34 age group in the five Nordic countries during the years 1984 and 1985 (Sweden only in 1984) were investigated. The known drug addicts were studied separately. The highest incidence of intoxications, calculated per 10(5) population, was found in Finland (11.3), followed by Denmark (10.3), Sweden (8.5), Iceland (7.2) and Norway (6.6). The percentage of intoxications caused by drugs was 92 in Denmark, 71 in Norway, 66 in Sweden, 50 in Finland and 17 in Iceland. Ethanol intoxications were seen 5-7 and 2-3 times as frequently in Finland and in Iceland, respectively, than in the other three countries. Carbon monoxide intoxications accounted for two-thirds of all fatal intoxications in Iceland. Drug addicts accounted for 62% of all fatal intoxications in the Danish material. The corresponding figures were 33% in the Norwegian, 16% in the Swedish and 5% in the Finnish material. No deaths in drug addicts were found in Iceland. Most drug addicts in Denmark, Norway and Sweden died of hard drugs and most in Norway and Sweden, from heroin or morphine, whereas in Denmark other strong analgesics, such as methadone, dextropropoxyphene and ketobemidone, accounted for 40% of all hard-drug-related fatal intoxications. To a certain extent the results reflect differences in the legal autopsy routines in the various Nordic countries. However, the ascertainment of drug addicts is assumed to be near-complete in each country.  相似文献   
2.
Two thousand fifty-three samples submitted to forensic chemical analysis during the period 1982-1987 were characterized according to their content of narcotics and the year of seizure. Heroin and cannabis dominated the material, but a significant decrease in the number of heroin samples was observed in 1987. Amphetamine, on the contrary, hardly seen during the period 1982-1984, accounted for half of the narcotics submitted in 1987. The misuse of morphine, especially in the form of poppy capsules, was a problem for some years, whereas cocaine has not yet been a drug of abuse in Denmark. The mean concentrations of the heroin and the amphetamine samples were 30% and 44%, respectively, both for retail drugs and the entire material.  相似文献   
3.
This paper is the fifth in a series of six in relation to the development of a harmonised method for the profiling of amphetamine [L. Aalberg, K. Andersson, C. Bertler, H. Borén, M.D. Cole, J. Dahlén, Y. Finnon, H. Huizer, K. Jalava, E. Kaa, E. Lock, A. Lopes, A. Poortman-van der Meer, E. Sippola, Development of a harmonised method for the profiling of amphetamines I. Synthesis of standards and compilation of analytical data, Forensic Sci. Int. 149 (2005) 219-229; L. Aalberg, K. Andersson, C. Bertler, M.D. Cole, Y. Finnon, H. Huizer, K. Jalava, E. Kaa, E. Lock, A. Lopes, A. Poortman-van der Meer, E. Sippola, J. Dahlén, Development of a harmonised method for the profiling of amphetamines II. Stability of impurities in organic solvents, Forensic Sci. Int. 149 (2005) 231-241]. The third paper [K. Andersson, K. Jalava, E. Lock, L. Aalberg, Y. Finnon, H. Huizer, E. Kaa, A. Lopes, A. Poortman-van der Meer, M.D. Cole, J. Dahlén, E. Sippola, Development of a harmonised method for the profiling of amphetamines III. Development of the gas chromatographic method, Forensic Sci. Int., in press] dealt with the optimisation of the gas chromatographic and detection methods whereas the fourth paper [K. Andersson, K. Jalava, E. Lock, Y. Finnon, S. Stevenson, L. Aalberg, H. Huizer, E. Kaa, A. Lopes, A. Poortman-van der Meer, M.D. Cole, J. Dahlén, E. Sippola, Development of a harmonised method for the profiling of amphetamines IV. Optimisation of sample preparation, Forensic Sci. Int., in press] concerned the optimisation of the extraction method prior to GC analysis. This paper is a study of the optimised method in order to determine its stability. Investigations of within and between day variations were carried out in four laboratories. Moreover, variations between laboratories were also determined. Both flame ionisation detector (FID) and MS detection were used. One laboratory studied nitrogen-phosphorous detector (NPD) detection as well. For this task, 12 batches of amphetamine were prepared. Six of them were synthesised via the Leuckart route, three via the nitrostyrene route and three via the reductive amination route [A.M.A. Verweij, Impurities in illicit drug preparations: amphetamine and methamphetamine, Forensic Sci. Rev. 1 (1989) 2-11]. Taking into account all studied target compounds and the average results from four laboratories, the within day variation was around 6% for FID and 5% for MS, the between days variation was around 10% for FID and 8% for MS. For NPD detection, within day variation was 5% and between days variation 9% (only one laboratory). Finally, the inter-laboratory variation was about 12% for FID (four laboratories) and 10% for MS (three laboratories).  相似文献   
4.
During the course of the referendum campaign, the Scottish government argued that free tuition for Scottish and EU students symbolised Scotland's preference for universal services and was intrinsically fairer than the ‘marketised’ systems operating in the rest of the UK. Invoking principles of both social justice and pragmatism, three distinct critiques of the Scottish government's higher education policy were mounted and adopted by different policy actors for different political purposes. Following a discussion of these arguments, this article concludes that a more nuanced discussion of higher education policy in Scotland is required, focusing not just on the absence of tuition fees but also on the distribution of debt and allocation of funds across the entire education system. We also note that the focus on tuition fees policy suggests that higher education systems across the UK are set on a process of divergence, whereas there are strong pressures towards policy convergence in areas such as research policy and internationalisation.  相似文献   
5.
6.
For many years dextropropoxyphene (dxp) has been the medicament most frequently occurring in drug poisoning cases examined at the Institute of Forensic Medicine, University of Aarhus. This study includes 85 cases of acute fatal poisoning examined in the period 1985-1987 in which dxp alone (40 cases) or in combination with alcohol (29 cases) and/or other drugs (16 cases) contributed significantly to death. Two-thirds of the deceased were men and one-third women. The average age was 37 years for both sexes. More than half of the deceased were drug and/or alcohol misusers. Eighteen were drug addicts. Half of the deaths resulted from accidents, while 40% were suicides. Accidental deaths prevailed among younger men. In a majority of the cases the drug had been taken orally. In these cases the median total blood concentration of dxp and the metabolite nordextropropoxyphene (ndxp) was 17 mg/kg in the suicide cases and 7.1 mg/kg in the accident cases. The corresponding figures for dxp without metabolite were 9.4 mg/kg and 2.2 mg/kg, respectively. The median value of the quotient dxp/ndxp was 1.9 in the suicide cases and 0.5 in the accident cases. The quotient, together with the concentrations of the drug, may therefore indicate the manner of death in many cases.  相似文献   
7.
This article examines the returns to education taking into consideration the existence of educational mismatches in the formal and informal employment of a developing country. Results show that the returns of surplus, required and deficit years of schooling are different in the two sectors. Moreover, they suggest that these returns vary along the wage distribution, and that the pattern of variation differs for formal and informal workers. In particular, informal workers face not only lower returns to their education, but suffer a second penalty associated with educational mismatches that puts them at a greater disadvantage compare to their formal counterparts.  相似文献   
8.
The suitability of liquid-liquid extraction (LLE) and solid-phase extraction (SPE) for the preparation of impurity extracts intended for gas chromatographic profiling analyses of amphetamine were evaluated. Both techniques were optimised with respect to the extraction of selected target compounds by use of full factorial designs in which the variables affecting the performance were evaluated. Test samples consisted of amphetamine synthesised by the Leuckart reaction, by reductive amination of benzyl methyl ketone and by the nitrostyrene route. The performance of LLE and SPE were comparable in terms of repeatability and recovery of the target compounds. LLE was considered the better choice for the present harmonised amphetamine profiling method due to the lack of information on the long-term stability of SPE columns.  相似文献   
9.
10.
This study focused on gas chromatographic analysis of target compounds found in illicit amphetamine synthesised by the Leuckart reaction, reductive amination of benzyl methyl ketone, and the nitrostyrene route. The analytical method was investigated and optimised with respect to introduction of amphetamine samples into the gas chromatograph and separation and detection of the target substances. Sample introduction using split and splitless injection was tested at different injector temperatures, and their ability to transfer the target compounds to the GC column was evaluated using cold on column injection as a reference. Taking the results from both techniques into consideration a temperature of 250 degrees C was considered to be the best compromise. The most efficient separation was achieved with a DB-35MS capillary column (35% diphenyl 65% dimethyl silicone; 30 m x 0.25 mm, d(f) 0.25 microm) and an oven temperature program that started at 90 degrees C (1 min) and was increased by 8 degrees C/min to 300 degrees C (10 min). Reproducibility, repeatability, linearity, and limits of determination for the flame ionisation detector (FID), nitrogen phosphorous detector (NPD), and mass spectrometry (MS) in scan mode and selected ion monitoring (SIM) mode were evaluated. In addition, selectivity was studied applying FID and MS in both scan and SIM mode. It was found that reproducibility, repeatability, and limits of determination were similar for FID, NPD, and MS in scan mode. Moreover, the linearity was better when applying FID or NPD whereas the selectivity was better when utilising the MS. Finally, the introduction of target compounds to the GC column when applying injection volumes of 0.2 microl, 1 microl, 2 microl, and 4 microl with splitless injection respectively 1 microl with split injection (split ratio, 1:40) were compared. It was demonstrated that splitless injections of 1 microl, 2 microl, and 4 microl could be employed in the developed method, while split injection and splitless injections of 0.2 microl should be avoided.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏