首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
DNA extraction from bone is an important issue particularly in paternity cases when bones are the only remaining material to obtain and analyze DNA. The difficulties arising from bacterial damages, taphonomic factors and diagenesis might negatively affect the extraction and the amplification of DNA. This makes the laboratory procedure a hard and time-consuming process, and the analysis can fail. Analyzing mini-STRs in this type of degraded samples is highly recommended. In this study a new extraction technique was carried on bone samples which were then typed for mini-STRs. The aim was to differentiate two genetically related skeletons found in the same familial grave for a paternity test. The analysis revealed that this new extraction technique along with mini-STR analysis can properly be an effective way to obtain and analyze DNA in bones in the field of forensic sciences.  相似文献   

2.
New multiplex PCR sets of commonly used short tandem repeat (STR) markers have been developed to produce PCR products that are reduced in size when compared to standard commercial STR kits. The reduction in size of these amplicons can facilitate the examination and analysis of degraded DNA evidence by improving amplification efficiency. This "miniSTR" approach will permit current forensic practitioners to use STR markers and instrumentation already present in their laboratories and to generate genotyping data that is directly comparable to reference samples and searchable through the FBI's Combined DNA Index System (CODIS) databases. This paper discusses the development of these new primer sets and presents some initial results in the analysis of degraded and aged DNA samples. A method for removal of problematic fluorescent dye artifacts is also described. Comparison studies in over 100 samples have verified that these miniSTR primers can provide fully concordant results to commercial STR kits and can provide improved signal from degraded DNA specimens. These miniplex sets should prove valuable in the analysis of samples where allele dropout and reduced sensitivity of larger STR alleles occurs.  相似文献   

3.
In forensic DNA analysis, the samples recovered from the crime scene are often highly degraded leading to poor PCR amplification of the larger sized STR loci. To avoid this problem, we have developed STR markers with redesigned primer sequences called "Miniplexes" to produce smaller amplicons. To assess the effectiveness of these kits, we have tested these primer sets with enzymatically degraded DNA and compared the amplifications to a commercial kit. We also conducted sensitivity and peak balance studies of three Miniplex sets. Lastly, we report a case study on two human skeletal remain samples collected from different environmental conditions. In both types of degraded DNA, the Miniplex primer sets were capable of producing more complete profiles when compared to the larger sized amplicons from the commercial kit. Correct genotypes were obtained at template concentrations as low as 31 pg/25 microL. Overall, our data confirm that our redesigned primers can increase the probability of obtaining a usable profile in situations where standard kits fail.  相似文献   

4.
Analysis of short tandem repeat (STR) markers currently represents the most useful instrument in the field of forensic genetics. The problem with forensic material is the degradation of the sample material. In recent years, several papers have demonstrated that short amplicon STR (miniSTR) represents one of the most useful tools for analyzing degraded DNA samples.In the present study, we attempted to develop a short amplicon STR multiplex system (autosomal and y-chromosomal) for analyzing degraded DNA using some newly designed primer sets for a multiplex polymerase chain reaction (PCR) systems for typing.An assay of degraded DNA samples using the designed multiplex systems, including artificially degraded samples and degraded forensic casework samples, proved remarkably effective. Comparing the multiplex with commercial kits, first results show a well success rate.  相似文献   

5.
Formalin-fixed and paraffin-embedded tissue (FF-PET) is an invaluable resource for retrospective molecular genetic studies, but the extraction of high-quality genomic DNA from FF-PET is still a problematic issue. Despite the range of DNA extraction methods currently in use, the association of phenol–chloroform extraction and silica-based purification protocols, reported in ancient DNA studies on archaeological bones, has, to our knowledge, not been used for DNA extraction from FF-PET yet. The present study compared the efficiency of three DNA extraction and purification protocols from two different FF-PET substrates, heart and liver, by using quantitative PCR and multiplex amplification.We showed that the method, using phenol–chloroform and the QIAamp DNA mini® Kit (Qiagen), was the most effective DNA extraction and purification method and that the DNA quantity extracted from liver is statistically more important than that extracted from heart. Autosomal STR typing by multiplex amplifications gave partial allelic profiles with only small size products (less than 300 bases) amplified, suggesting that DNA extracted from FF-PET was degraded.In conclusion, the protocol presented here, previously described in studies on ancient bones, should find application in different molecular studies involving FF-PET material.  相似文献   

6.
It is common in forensic casework to encounter highly degraded DNA samples from a variety of sources. In this category bone and teeth samples are often the principal source of evidential material for criminal investigations or identification of long-deceased individuals. In these circumstances standard STRs are prone to fail due to their long amplicon sizes (since DNA becomes progressively more fragmented as it degrades). To successfully resolve such cases alternative markers can be used and until recently the only other tool available was mitochondrial DNA, which despite being more resistant to degradation, is much less informative. A rapidly developing approach to analyzing degraded DNA is the typing of loci from short-amplicon PCR products based on markers such as mini-STRs and autosomal SNPs. We have performed an analysis of several cases with naturally degraded DNA using established STRs plus mini-STRs and autosomal SNPs in order to make an objective comparison of the performance of each method using challenging DNA. The main aim was to establish the benefits and drawbacks of each marker set to help the practitioner choose the DNA analysis method most suited to the circumstances of each case.  相似文献   

7.
一种改良骨骼DNA的提取方法   总被引:6,自引:4,他引:2  
采用十六烷基三甲基溴化铵(简称CTAB)及两次纯化浓缩的方法提取骨骼DNA,利用荧光标记复合扩增、自动毛细管电泳与分型的技术,成功检测到14个STR位点的分型.该方法稳定、结果可靠,为严重降解骨骼DNA的提取提供了一种可参用的方法.  相似文献   

8.
This paper describes a developmental validation study of three Miniplex sets covering 12 of the 13 CODIS loci. As these new sets will be used for the analysis of degraded and low level DNA, the validation studies were performed using 100-125 pg of DNA, the lowest input level at which peak balance, peak intensity, and allele consistency were stable. To demonstrate the applicability of the Miniplex sets to forensic casework, these validation studies were completed in accordance with the Scientific Working Group on DNA Analysis Methods (SWGDAM). A range of tests were performed including studies of concordance with standard multiplex kits, sensitivity and reproducibility, and PCR amplification conditions. Additionally, studies of mixtures, nonhuman and environmentally degraded DNA, and simulated forensic samples were performed. Our results demonstrate that Miniplex STR amplification procedures are a robust and sensitive tool for the analysis of degraded DNA.  相似文献   

9.
A universal method allowing for DNA profiling from bones exposed to seawater has not been reported yet. This study refers on the identification of a body immersed in seawater for 8 months. The biological material for identification was the mandibular body, usually characterized by low success rates of DNA analysis. Initially, two extraction protocols were performed with negative results: one used for bones immersed in fresh water and a silica‐column procedure. A third protocol was performed, which combined the extraction of a higher amount of bone powder, the use of multi‐silica‐based extraction columns followed by a concentration step. This protocol allowed to obtain low copy number DNA and to generate a 12‐loci STR profile by combining conventional STR typing and mini‐STR technologies. This protocol could be suitable when human bones have been exposed to severe environmental conditions, and the available nuclear DNA is highly degraded and in low copy number.  相似文献   

10.
The successful extraction of DNA from historical or ancient animal bone is important for the analysis of discriminating genetic markers. Methods used currently rely on the digestion of bone with EDTA and proteinase K, followed by purification with phenol/chloroform and silica bed binding. We have developed a simple concentrated hydrochloric acid-based method that precludes the use of phenol/chloroform purification and can lead to a several-fold increase in DNA yield when compared to other commonly used methods. Concentrated hydrochloric acid was shown to dissolve most of the undigested bone and allowed the efficient recovery of DNA fragments <100 bases in length. This method should prove useful for the recovery of DNAs from highly degraded animal bone, such as that found in historical or ancient samples.  相似文献   

11.
Blood stained soils may be of great interest in forensic incidents. Amplification of DNA from soil is often inhibited by co-purified contaminants. Different soils types from Pakistan and Turkey were stained with blood and samples were collected systematically after specified intervals. Rapid, inexpensive, large-scale DNA extraction method involving minimal purification was developed. DNA was quantized using Spectrophotometer and Fluorometer and was confirmed by Agarose Gel Electrophoresis. DNA extracted from different soils in different periods showed a remarkable decrease in yield as well as degradation in every extraction. PCR amplification was performed using various DNA targets present in Promega 16 Powerplex® System kit. Amplification could not carry out in all loci especially in degraded samples taken after 20 days. Allele n locus drop out was noticed which shows that DNA was degraded. For some loci more than 2 alleles were also noticed showing contamination while working with the blood stained soils.  相似文献   

12.
Personal products, such as toothbrushes, have been used as both known reference and evidentiary samples for forensic DNA analysis. This study examined the viability of a broad selection of cosmetic applicators for use as targets for human DNA extraction and short tandem repeat (STR) analysis using standard polymerase chain reaction (PCR) conditions. Applicator types included eyeliner smudgers, pencils and crayons, eye shadow sponges, mascara wands, concealer wands, face makeup sponges, pads and brushes, lipsticks and balms, and lip gloss wands. The quantity and quality of DNA extracted from each type of applicator were examined by assessing the number of loci successfully amplified and the peak balance of the heterozygous alleles in each full STR profile. While degraded DNA, stochastic amplification, and PCR inhibition were observed for some items, full STR profiles were developed for 14 of 76 applicators. The face makeup sponge applicators yielded the highest proportional number of full STR profiles (4/7).  相似文献   

13.
The recovery of DNA data from old skeletal remains is often difficult due to degraded and very low yield of extracted DNA and the presence of PCR inhibitors. Herein, we compared several silica-based DNA extraction methods from artificially degraded DNA, DNA with PCR inhibitors and DNA from old skeletal remains using quantitative real-time PCR. We present a modified large-scale silica-based extraction combined with complete demineralization, that enables maximum DNA recovery and efficient elimination of PCR inhibitors. This is performed with high concentration of EDTA solution for demineralization of bone powder followed by QIAamp® spin columns and buffers from the QIAquick® PCR purification kit. We have successfully used this modified technique to perform STR analysis for 55-year-old skeletal remains. The results of this study will contribute to solve the forensic cases dealing with skeletal remains.  相似文献   

14.
Fingerprinting brushes have the potential to collect and transfer DNA during powdering. Squirrel-hair fingerprint brushes exposed to specific sets of saliva stains and brushes used in routine casework were tested for their ability to collect and transfer DNA containing material using standard DNA extraction procedures and AmpFlSTR Profiler Plus amplification and typing procedures. The tests found that the risk of transferring DNA during powdering and having a detrimental impact on the analysis increases if the examiner powders over either biological stains (such as blood or saliva) or very fresh prints and uses more sensitive PCR amplification and typing procedures. We advocate caution when powdering prints from which DNA may also be collected and provide options for consideration to limit the risk of transferred DNA contamination while fingerprinting.  相似文献   

15.
《Science & justice》2020,60(5):423-431
DNA samples collected at crime scenes are often degraded so this research focused on the ability of the Promega PowerPlex® Fusion 5C amplification kit to type both naturally and artificially degraded DNA.DNA was degraded naturally by placing equal volumes of blood on white fabric that was stored either inside, outside in a shaded area, or outside in direct sunlight. Samples were then collected every 10 days for 60 days and the DNA extracted (QIAamp® DNA Investigator). Artificially degraded samples were created by exposing extracted DNA to either UV light or 95 °C heat for varying times. DNA was also degraded artificially by placing blood samples into a 50% bleach solution for varying times prior to extraction.Following sample treatment, standard forensic DNA analysis was performed including quantification (Investigator® Quantiplex) and amplification (PowerPlex® Fusion 5C). Separation and detection were performed on an ABI 3130xl capillary electrophoresis unit and analysis was performed using GeneMapper ID v3.2.1.While the time and shade samples showed similar amounts of degradation, the samples exposed to direct sun showed more degradation. The artificially degraded samples showed more signs of degradation such as reduced overall peak height and peak height imbalance at heterozygous loci. There were also some cases where an allele that was known to be in the profile exhibited total dropout. Although there were some instances of both allelic dropout and heterozygote peak imbalance, PowerPlex® Fusion was able to reliably type degraded DNA as all alleles detected were consistent with the known donor profile. The results show that PowerPlex® Fusion is a robust kit capable of handling forensically challenged samples.  相似文献   

16.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

17.
MiniSTR技术的研究进展   总被引:3,自引:2,他引:1  
Wang HP  Liu C  Sun HY 《法医学杂志》2006,22(2):159-160,I0001,I0002
短串联重复序列(STR)是法医DNA鉴定中最常用和最重要的遗传标记,但是对于降解和微量的DNA样品,经常得不到完整的DNA分型甚至分型失败。MiniSTR技术通过设计更靠近重复序列的引物,得到更短一些的STR基因座,提高了降解和微量检材的DNA分型成功率。本文综述了miniSTR技术的研究进展,以服务于法医学实践。  相似文献   

18.
An optimized protocol based on the DNA IQ™ System has been tested for the extraction of DNA from envelope flaps. DNA is extracted directly without the need for opening and swabbing the flaps. The method is repeatable with <10% R.S.D. (relative standard deviation). The results of a systematic study show that it is an equilibrium extraction, and a small sample volume as well as high lysis buffer content in sample contribute to high extraction efficiency. The extracted DNA requires no further purification steps following its extraction with the DNA IQ™ System. Complete but skewed 15-locus short tandem repeat (STR) profiles, which is typical of degraded of DNA, have been generated from the DNA extracted from 6 to 9 years old casework envelope samples.  相似文献   

19.
Abstract: As a powerful alternative to short tandem repeat (STR) profiling, we have developed a novel panel of 47 single nucleotide polymorphisms (SNPs) for DNA profiling and ABO genotyping. We selected 42 of the 47 SNPs from a panel of 86 markers that were previously validated as universal individual identification markers and identified five additional SNPs including one gender marker and four ABO loci. Match probability of the 42 validated SNPs was found to be 9.5 × 10?18 in Han Chinese. SNP analysis correctly assessed a panel of historical cases, including both paternity identifications in trios and individual identifications. In addition, while STR profiling of degraded DNA provided information for 11 loci of 16 potential markers with low peak intensities, SNPstream® genotyping was sufficient to identify all 47 SNPs. In summary, SNP analysis is equally effective as STR profiling, but appears more suited for individual identification than STR profiling in cases where DNA may be degraded.  相似文献   

20.
Sexual assault evidence samples require the use of a specific process known as a differential digestion to separate sperm from nonsperm cells prior to DNA extraction. An automated differential digestion process was developed using a selective degradation technique, which uses DNase I to digest the remaining nonsperm DNA in the sperm fraction. The use of DNase on pristine samples, as well as aged and degraded samples, was assessed to ensure that the quantity and quality of the sperm DNA were not compromised or adversely affected. Samples processed using the selective degradation technique yielded comparable DNA yield and DNA typing data to the conventional differential digestion process. The automated process utilized 96‐well plates for high throughput and incorporated microscope slide preparations for confirmation of sperm. It reduced processing time by about sixfold and was paramount in the elimination of the Oakland Police Department Criminalistics Laboratory's sexual assault kit backlog.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号