首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Laboratory procedures used in short tandem repeat (STR) analysis were subjected to various scenarios that assessed reliability and identified potential limitations. These validation studies were designed as recommended by the Technical Working Group on DNA Analysis Methods (TWGDAM) and the DNA Advisory Board (DAB) (17,18). Various DNA samples were amplified by the polymerase chain reaction (PCR) using AmpFlSTR PCR Amplification Kits (i.e., AmpFlSTR Green I, Profiler, Profiler Plus, and COfiler kits), detected with ABI Prism instrumentation, and analyzed using GeneScan and Genotyper software. Data acquired in these studies reinforced an existing body of knowledge and expertise regarding application and interpretation of STR typing in the forensic science community. Consistent STR genotypes were detected in various body tissues and fluids. Inter-laboratory comparisons produced concordant genotype results. Quantitative interpretational aids for DNA mixtures were characterized. Ability of the typing systems to type potentially compromised samples reliably was evaluated. Nonprobative case evidentiary DNA was successfully amplified, genotyped, and interpreted. Potential limitations or cautionary factors in the interpretation of minimal fluorescence intensity were demonstrated. Differential amplification between loci was observed when PCR was inhibited; preferential amplification typically was not. Single AmpFlSTR locus amplification did not offer consistent benefit over AmpFlSTR multiplexing, even in cases of DNA degradation or PCR inhibition. During rigorous evaluation, AmpFlSTR PCR Amplification Kits reproducibly yielded sensitive and locus-specific results, as required in routine forensic analyses.  相似文献   

2.
Post-vasectomized azoospermic semen samples (N = 6) were analyzed for short tandem repeats (STR) on the Y-chromosome by using Y-PLEX 6 and the 310 Genetic Analyzer. We have observed a wide variation in the yield of extracted DNA from 12.5-1,000 ng. This variation was attributed to the number of epithelial and/or white blood cells that are present in these azoospermic samples. DNA profiles of these vasectomized males were obtained for all six Y-STR loci, namely DYS393, DYS 19, DYS389II, DYS390, DYS391, and DYS385 amplified by using the Y-PLEX 6.  相似文献   

3.
The performance of two commercial multiplex kits that together amplify the 13 core short tandem repeat (STR) loci currently in use by forensic laboratories and the U.S. national Combined DNA Indexing System (CODIS) were evaluated. The typing systems examined were AmpFlSTR Profiler Plus and AmpFlSTR COfiler (PE Applied Biosystems, Foster City, CA). Electrophoretic separation and detection of the fluorescent PCR products was achieved by capillary electrophoresis (CE) using an ABI Prism 310 Genetic Analyzer. The studies addressed the on-site validation of the instrument, the software, and each typing system. These studies included instrument sensitivity, resolution, precision, binning, peak height ratios, mixtures, stutter, and the amplification of non-probative and simulated forensic samples. Other additional developmental-type work is also reported herein, such as species specificity testing and amplification of environmentally insulted samples. Amplification conditions were found to be robust and the primer sets shown to be specific to human DNA. Stutter and peak height ratios fell within limits published by the manufacturer and other laboratories. The data demonstrate that the CE instrument can consistently resolve fragments differing in length by one base and that the +/-0.5 base bin used by the Genotyper software is acceptable for making accurate allele calls. Correct typing results were obtained from non-probative and simulated case samples, as well as samples exposed to outdoor environmental conditions. The results support the conclusion that DNA extracted from biological samples routinely encountered in the forensic laboratory can be reliably analyzed with AmpFlSTR Profiler Plus and COfiler using CE.  相似文献   

4.
Nuclear DNA was extracted from human telogen hairs from 60 individuals. Six to nine hairs from each individual were individually extracted. The amount of DNA recovered from each individual varied greatly, and most samples yielded a quantity of 550 pg or less per hair. A selective extraction buffer was used to remove epithelial cell DNA and the amount of exogenous DNA was determined. DNA was also quantified by real time PCR using three different sized amplicons targeting an Alu sequence. The results were used to determine the state of degradation of the extracted DNA. Different quantities of sample (<100 pg, 100-500 pg, >500 pg) were amplified with the Miniplex kits to determine the minimum DNA template required for successful amplification. DNA recovered from hair showed degradation; however, partial profiles were obtained for those samples containing at least 60 pg using MiniSTRs.  相似文献   

5.
A population study on 10 short tandem repeat (STR) loci was performed on 202 unrelated Czech Caucasians. DNA, initially frozen, was thawed and placed FTA paper. The DNA was purified in situ. DNA was amplified by PCR using the AmpFlSTR SGM Plus amplification kit.  相似文献   

6.
7.
During an extensive multipopulation study with Y-short tandem repeat (STR) loci, amplified using the AmpFlSTR Yfiler PCR amplification kit, amplification of a 71 bp fragment was observed in 2.32% of the male samples analyzed (N = 3141). By direct sequencing of this fragment, it was determined that the primer binding sequences were identical to those of the DYS456 locus. A T to G single-nucleotide polymorphism (SNP) enabled amplification of the 71 bp fragment. The SNP is located within an X-Y homologous region at Xq21.31 and was observed with the highest frequency within the African American and Sub-Saharan African populations in our study. Presence of SNP on the X chromosome did not interfere with the reliability of typing the DYS456 locus and the other Y-STR loci typeable using the AmpFlSTR Yfiler PCR amplification kit. Full profiles in a mixture of male:female at 1:4000 were obtained using the current configuration of the AmpFlSTR Yfiler kit even in the presence of female DNA containing the G variant.  相似文献   

8.
The aim of this research was to obtain DNA profiles from immunochromatographic test devices which have already yielded positive results with body fluids obtained from fourteen volunteers. Three different immunochromatographic cards for the identification of human blood and one for the identification of human saliva were used for this research. Each body fluid was detected using the appropriate immunochromatographic card. The used cards were kept at room temperature for various lengths of time. The membranes were removed at the end of the designated times and the entire strip was extracted using low copy number (LCN) extraction procedure. The extracted DNA was amplified using reduced amplification volume and higher PCR cycle numbers. Autosomal STR profiles were detected using AmpFℓSTR® Identifiler™ PCR Amplification Kit from Applied Biosystems (AB). Additionally, DNA extracted from the male volunteers was amplified using the AB AmpFℓSTR® Yfiler™ PCR Amplification Kit. Analysis of the amplified products was carried out by capillary electrophoresis injection on the AB 3130xl Genetic Analyzer. The generated DNA data was analyzed using the SoftGenetics GeneMarker® HID Version 1.7 software.Autosomal and Y-STR DNA profiles were obtained from most of the cards which were stored at room temperature for up to three months. DNA profile was obtained from all four types of the immunochromatographic cards used in this study. These profiles were concordant with the profiles obtained from the donors’ reference samples.  相似文献   

9.
The Y-PLEX 12 system, developed for use in human identification, enables simultaneous amplification of eleven polymorphic short tandem repeat (STR) loci, namely DYS392, DYS390, DYS385 a/b, DYS393, DYS389I, DYS391, DYS389II, DYS 19, DYS439 and DYS438, residing on the Y chromosome and Amelogenin. Amelogenin provides results for gender identification and serves as internal control for PCR. The validation studies were performed according to the DNA Advisory Board's (DAB) Quality Assurance Standards. The minimal sensitivity of the Y-PLEX 12 system was 0.1 ng of male DNA. The mean stutter values ranged between 3.76-15.72%. A full male profile was observed in mixture samples containing 0.5 ng of male DNA and up to 400 ng of female DNA. Amelogenin did not adversely affect the amplification of Y-STRs in mixture samples containing male and female DNA. The primers for the Y-STR loci present in Y-PLEX 12 are specific for human DNA and some higher primates. None of the primate samples tested provided a complete profile at all 11 Y-STR loci amplified with the Y-PLEX 12 system. Y-PLEX 12 is a sensitive, valid, reliable, and robust multiplex system for forensic analysis, and it can be used in human forensic and male lineage identification cases.  相似文献   

10.
The Israel police forensic biology laboratory received as an item of evidence in an attempted murder case, a pair of trousers belonging to a suspect. A bloodstain was observed on the trousers and analyzed by STR typing for nine loci using the Promega GenePrint STR silver stain detection kits. The genetic profile defined was found to be identical to that of the victim's at all nine loci. Within this profile a three-banded allele pattern was observed at the D16S539 locus, both in the bloodstain and in the victim's reference blood sample. Confirmation of this phenomenon was accomplished by amplifying the extracted DNA from both the trousers and the victim's blood sample using the PowerPlex 16 kit by Promega and the AmpFlSTR SGM Plus kit by Perkin Elmer, followed by analysis of the amplification products by capillary electrophoresis on the ABI prism 310 genetic analyzer. The same three-banded allele pattern was observed at the D16S539 locus in both specimen and reference DNA, using each of the three kits. Three additional loci located on chromosome 16 (D16S3407, D16S2617 and D16S3082), not employed for forensic identification, were also analyzed and did not show three-banded allele pattern.  相似文献   

11.
12.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

13.
目的建立一套显微细胞捕获技术用于法医学生物检材DNA检验方法。方法使用VeritasTM LCM激光捕获仪,采用紫外加红外的捕获方式,对框架覆膜玻片上经苏木素染色口腔上皮细胞进行捕获,采用改良硅珠法提取细胞DNA,使用Identifiler TM试剂盒在5μL体系中进行PCR扩增。结果成功获得20个口腔上皮细胞的13个以上完整STR基因座分型谱带。结论本研究建立的方法适合法医学生物检材制成的染色涂片上细胞的DNA检验。  相似文献   

14.
The analysis of LCN or highly degraded DNA samples presents a challenge for forensic science. Improving the quantity and/or quality of samples would greatly increase the profiling success rate from LCN and degraded samples. Whole genome amplification (WGA) is one method that has such potential. Two commercially available WGA kits, GenomePlex and GenomiPhi, were investigated for use on LCN and degraded DNA samples. Both kits amplified genomic DNA, producing microgram quantities from sub-nanogram templates. Profiling success of LCN DNA samples was increased, with improvements of over 700% from 10pg template DNA compared to non-WGA-amplified control samples. The amplification success with degraded DNA was also improved by WGA. Degraded DNA was simulated using restriction enzymes to demonstrate that the application of WGA can result in the typing of STR loci that could not previously be amplified. An increase in artefacts, such as stutter alleles and amplification biases, were observed in many samples. Results show that WGA is capable of increasing both the quality and quantity of DNA, and has the potential to improve profiling success from difficult samples in forensic casework.  相似文献   

15.
The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.  相似文献   

16.
DNA isolation from hair shafts can involve a number of steps, each of which adds time to the procedure and increases the risk of contamination. A simple alkaline digestion procedure that directly dissolves hairs was developed and compared with a widely used glass grinding/organic extraction method, using samples collected from 30 volunteers with varying population ancestries, hair colors, and hair treatments. A 203 bp mtDNA product could be amplified from 90% of samples extracted by alkaline digestion and 73% of hairs extracted by glass grinding. DNA obtained from alkaline digested hair generated equal or greater amplification success for virtually all criteria examined, and mtDNA sequences matched buccal control sequences in all cases. The two methods were similar in DNA yield (amplification success at template dilution) and quality of DNA obtained (amplicon length). Alkaline digestion of hair shafts required 6-7 h to complete, compared to 22-24 h for glass grinding, and proved a less laborious yet equally robust method for mtDNA extraction.  相似文献   

17.
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.  相似文献   

18.
There are many techniques available for the recovery of fingermarks at scenes of crime including the possibility of taking casts of the marks. Casts can be advantageous in cases where other destructive recovery techniques might not be suitable, such as when recovering finger marks deposited on valued or immobile items. In this research, Isomark (a silicone-based casting material) was used to recover casts of finger marks placed on a variety of substrates. Casts were enhanced using cyanoacrylate fuming. Good quality marks were successfully recovered from a range of smooth, non-porous surfaces. Recovery from semi-porous surfaces was shown to be inefficient. DNA was subsequently extracted from the casts using QIAamp Mini extraction kits, amplified and profiled. Full DNA profiles were obtained 34% of samples extracted.  相似文献   

19.
A new set of multiplexed PCR primers has been applied to the analysis of human skeletal remains to determine their efficacy in analyzing degraded DNA. These primer sets, known as Miniplexes, produce shorter amplicons (50-280 base pairs (bp)) than standard short tandem repeat (STR) kits, but still utilize the 13 CODIS STR loci, providing results that are searchable on national DNA databases. In this study, a set of 31 different human remains were exposed to a variety of environmental conditions, extracted, and amplified with commercial and Miniplex DNA typing kits. The amplification efficiency of the Miniplex sets was then compared with the Promega PowerPlex 16 system. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only 16% of the samples generated full profiles with the Powerplex 16 kit. Complete profiles were obtained for 11 of the 12 Miniplex loci with amplicon sizes less than 200 bp. These data suggest smaller PCR amplicons may provide a useful alternative to mitochondrial DNA for anthropological and forensic analysis of degraded DNA from human skeletal remains.  相似文献   

20.
Lin Y  Li L  Liu Y  Zhao ZM 《法医学杂志》2010,26(6):446-448
目的通过对X染色体SNP遗传标记的检测,探讨甲醛固定组织块的DNA分型策略。方法提取甲醛固定组织块的DNA,在用SinofilerTM试剂盒、MiniFilerTM试剂盒检测未能获得分型结果的情形下,采用多重PCR和飞行质谱技术对X染色体上的51个SNP位点进行分型检测。结果对于常染色体STR、miniSTR分型失败的甲醛固定组织块,X-SNP分型获得成功。结论对于甲醛固定组织块等微量、降解的生物学检材,若常染色体STR基因座分型失败,可尝试进行SNP位点的分型,以获得更多的遗传信息。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号