首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Methamphetamine (MA) is one of the most frequently abused drugs worldwide. The aim of this study is to improve the analytical method for profiling MA impurity in order to compare and classify MA crystals seized in different countries and to investigate the relationships between seizures. To compare MA samples seized in Japan and Thailand, the following analytical method was adopted. A 50mg sample of MA.HCl was dissolved in 1ml of buffer solution (four parts 0.1M phosphate buffer, pH 7.0, and one part 10% Na(2)CO(3)), impurities were extracted with 0.5ml of ethyl acetate containing four internal standards (n-decane, n-pentadecane, n-eicosane and n-octacosane) and analyzed by gas chromatography with a flame ionization detector on a DB-5 capillary column (0.32mm i.d.x30m, film thickness 1.0mum). Fourteen characteristic peaks on chromatograms were selected for the comparison and classification of samples, and the data were evaluated by the Euclidean distance of the relative peak areas after logarithmic transformation. Sixty-nine samples seized in Japan and 42 seized in Thailand were analyzed. The samples were classified into four groups roughly by cluster analysis. In addition, when it was difficult to compare samples that had fewer impurities on chromatograms obtained from liquid-liquid extraction (LLE), solid-phase microextraction (SPME) was effective. Because many characteristic peaks were detected using SPME, SPME made it easy to compare samples of high purity. The combination of LLE and SPME was useful for impurity profiling of MA samples seized in different countries.  相似文献   

2.
Methamphetamine hydrochloride is one of the most widely used illicit drugs in the Philippines. In this study, we describe the application of cluster analysis of trace impurities in the profiling of the seized methamphetamine drug samples. Thirty milligrams of a homogenized drug sample were dissolved in 1 mL of pH 10.5 buffer solution and extracted with ethyl acetate containing three internal standards. The trace impurities were identified using gas chromatography-mass spectrometry (GC-MS) and quantified by gas chromatography with a flame ionization detector (GC-FID). Following previously reported methodologies, 30 impurity peaks were selected from the GC-FID chromatograms. The peak areas and retention times were referenced to the internal standards. The peak areas of the selected peaks were then grouped for cluster analysis. In order to check for consistency of clustering, two further cluster analyses were performed using 40 and 50 impurity peaks. Changes in clustering were observed in going from 30 to 40 impurity peaks, while analyses using 40 and 50 impurity peaks gave similar results. Thus, for the seized drug samples used in this study, cluster analysis using at least 40 impurity peaks showed better consistency of clustering as compared to analysis using 30 peaks only. Ten of the impurity peaks were identified, of which four were identified for the first time in methamphetamine drug samples. These are p-bromotoluene, N-benzyl amphetamine, N-ethyl amphetamine, and N-ethyl methamphetamine. The presence of phenyl-2-propanone (P2P), N,N-dimethyl amphetamine, and N-formyl amphetamine is indicative that these casework samples were synthesized using the Leuckart method.  相似文献   

3.
Gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS) are commonly used for the impurity profiling of illegal drugs. For the impurity profiling of methamphetamine, it is very important to obtain information about impurities related to the manufacturing route and the precursor chemicals [B. Remberg, A.H. Stead, Drug characterization/impurity profiling, with special focus on methamphetamine: recent work of the United Nations International Drug Control Programme, Bull. Narcotics LI (1999) 97-117 ]. There are many artifact impurities arising from the preparation of samples and conditions of GC. Moreover, some impurities pose a barrier to the statistical processing of methamphetamine profiling. We investigated capillary GC analysis using pulsed splitless (PS/L) injection to minimize the thermal decomposition of impurities at the injection port and improve the transfer of samples into the column. We confirmed that the optimal conditions of PS/L-mode are 230 degrees C (injection temperature), 50 psi (pulsed pressure) and 1.1 min (pulsed time) for the methamphetamine profiling. Based on the impurity profiles of 48 methamphetamine crystals in PS/L-mode, we can achieve very easy handling and obtained, good results.  相似文献   

4.
Impurity profiling of methamphetamine (MA) using thermal desorption (TD) and gas chromatography-mass spectrometry (GC-MS) was examined. Using TD/GC-MS, impurities were extracted and separated under various conditions. Optimal chromatograms were obtained when a 20 mg MA sample was extracted at 120 degrees C for 3 min using a TD instrument, followed by separation of the extracts using a non-polar capillary column coated with (5%phenyl)-methylpolysiloxane. MA samples from nine different batches were analyzed under optimized conditions. Compounds related to the structure of MA, such as benzaldehyde, benzyl alcohol, amphetamine, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, and N-acetylephedrine, were detected in the chromatograms without any laborious extraction procedure. Compounds such as ethanol, diethyl ether, and acetic acid, which are considered reagents and solvents for MA synthesis, were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different among the samples. Impurity profiling of MA using TD was compared with that using liquid-liquid extraction (LLE). Better reproducibility of peak areas was obtained using LLE, whereas higher intensities and numbers of peaks were detected using TD. Solvents were extracted more effectively using TD. The nine batches of MA were classified using both extraction procedures. The nine batches were divided roughly into two groups using data from LLE. Subsequently, the groups were classified in detail using data from TD. TD can be used to provide supplemental information for LLE, and the combination of these extraction methods can be helpful for impurity profiling of MA.  相似文献   

5.
Organic impurities of methamphetamine may show different patterns by synthesis. In the present study, we tried to find the impurities reflecting the conditions of synthesis by comparing impurity patterns of the methamphetamine samples synthesized by different methods. Sixteen methamphetamine samples were synthesized from ephedrine and pseudoephedrine by the three different manufacturing methods of Emde, Nagai and Moscow. The synthesized samples were extracted with ethyl acetate containing four internal standards, and the patterns of the organic impurities were investigated by GC-MS and GC-FID . Through the investigation, we found 10 peaks appearing in the latter part of GC chromatograms are characteristic to synthesis. The areas of the selected peaks were converted to the variables suitable for the statistical calculation, and the synthesized samples could be classified into four groups through the resultant cluster analysis.  相似文献   

6.
Impurity profiling and classification of seized methamphetamine may play an important role in the interpretation of analytical results, the determination of the synthetic method employed, and the criminal investigations of drug traffic routes. Our study is focused on classifying seized methamphetamine samples according to the groups sorted by the types and quantities of impurities present in illicit methamphetamine samples. The samples (100 mg) were dissolved in 2 mL of potassium phosphate buffer (pH 7.0), extracted with 200 μL of ethyl acetate under basic condition, and then analyzed by gas chromatography-mass spectrometry (GC–MS) with a DB-1 capillary column (30 m × 0.25 mm i.d., 0.25 μm). Five impurities are used as criteria for the classification of seized methamphetamine samples by Emde and Nagai method. A total of fifty-two samples of seized methamphetamine were analyzed by GC–MS and classified by five organic impurities, and then sorted into four groups, which are Nagai type, Emde Type, Undetermined I type, and Undetermined II type.  相似文献   

7.
Nineteen crystalline methamphetamine ('ice') seizures captured by the Australian Federal Police (AFP) at the Australian border between 1998 and 2002 were analysed. Using a modified gas chromatograph-mass spectrometry (GC-MS) impurity profiling approach of these samples we have identified >30 compounds associated with methamphetamine and/or its synthetic route. Major impurities detected include 1,2-dimethyl-3-phenylaziridine 8, dimethylamphetamine 14, N-formylmethamphetamine 24, N-acetylmethamphetamine 25, 1,3-dimethyl-2-phenylnaphthalene 32, 1-benzyl-3-methylnaphthalene 33 and methamphetamine dimer 34. These data are suggestive of ephedrine/pseudoephedrine as the main precursor of the 'ice' samples seized during 1998-2002. Additionally the two naphthalenes 32 and 33 further identified that 15 items in 9 seizures were produced via the more specific ephedrine/hydriodic acid/red phosphorus method. One sample comprised 75% dimethylamphetamine and 9.7% methamphetamine, representing the first Australian seizure of imported dimethylamphetamine reported.  相似文献   

8.
Impurities in 48 methamphetamine (MA) samples were analyzed by liquid-liquid extraction (LLE) and headspace solid-phase microextraction (HS-SPME) methods. MPS-2 autosampler was used to improve reproducibility of SPME method, and nonadecane (C(19)) diluted with potassium bromide (KBr) powder was used as an internal standard for standardizing retention time. Impurities identified by SPME method showed different patterns compared with LLE method. Non-volatile impurities like methamphetamine dimer were not identified by SPME method, but some volatile impurities like diphenylketone, caprolactam and lots of unknowns were identified only by SPME method. 1-Phenyl-2-propanone (P2P), 1-phenyl-2-propanol and benzylcyanide peaks could be discriminated clearly by SPME method without interference of amphetamine, an artifact originates from MA degradation. Differences in the impurity patterns resulted in different clustering results. When 48 MA samples were classified into 5 LLE and 5 SPME clusters, cross-matching of the clusters resulted in 8 sub-clusters. It shows that combination of the different extraction methods can distinguish the differences which cannot be distinguished by LLE or SPME method alone, and can improve reliability of the profiling results.  相似文献   

9.
A novel ring-substituted methamphetamine regioisomer, N,alpha,4-trimethyl phenmethylamine, was synthesized in order to study the validity of proposed structures for various mass spectrometry (MS)-derived peaks in a methamphetamine fragmentation pattern. While other research efforts have studied aspects of methamphetamine in detail, a full fragmentation study has not been reported previously. In addition to showing molecular structures represented by fragment peaks, mechanisms for selected processes are detailed. An empirically derived procedure to easily determine by simple spectral peak pattern recognition the geometry of dimethyl- or ethyl-substituted immonium ions (RRC = N+ RR) where m/z = 58 is outlined. These results are platform independent for electron ionization (EI) instruments, but have also proven to be helpful in explaining spectral peaks observed in spectra from ion trap systems. The spectrum for the synthesized methamphetamine regioisomer was accurately predicted using this methodology. While this approach is useful in some casework, the converse may be more useful: when an unexpected or unusual peak pattern arises in a spectrum, being able to analyze it to determine the structure of the molecule. This paper gives an analyst the means to begin such retro-synthetic analyses.  相似文献   

10.
In Hong Kong, ecstasy tablets are more commonly known as "Fing Tau Yuen", literally meaning "Shake Head Pills". The tablets contain mainly amphetamine-type stimulants (ATS) including 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MA) and/or ketamine. Adulterant such as caffeine was also detected in the tablets. This paper reports a study on the impurity profiles of ecstasy tablets from 89 seizures in Hong Kong from 2002 to early 2004. Tablet samples were extracted by diethyl ether under alkaline condition and then analyzed by gas GC-MS. The chromatograms obtained were compared. A total of 19 identified impurities were selected as markers for impurity profiling. They are different precursors, intermediates and by-products. The data matrices were examined by hierarchical cluster analysis (HCA), and then the ecstasy tablets were classified into different groups. Cluster analysis of ecstasy tablets is shown to be capable of providing intelligence on clandestine laboratory networks.  相似文献   

11.
In this study, δ13C values of six cocaine samples were identified and classified using a single quadrupole mass spectrometer and an isotope ratio mass spectrometry (IRMS) as simultaneous gas chromatography detectors. Our instrument modification is simple to use and is useful (i) when the sample is of limited size or can only be injected once, (ii) to help identify peaks in a complicated IRMS chromatogram, and (iii) to help differentiate very simple systems when impurity profiling is not possible. The EI-MS confirmed the identity of cocaine in each sample. The IRMS data distinguished 12 of the 15 possible pair-wise comparisons at the 95% CL. Three samples could not be differentiated by their δ13C ratios for cocaine. ANOVA demonstrated that the measurement variance was consistently larger than the sample variance. As the δ13C values clearly show, this technique enables the exclusion of a potential common source even when two samples have otherwise identical chemical and physical properties.  相似文献   

12.
Smuggling of methamphetamine is affected by enforced regulation and international situation, resulting in changes of precursors and synthetic methods used. Enantiomer ratio of methamphetamine can provide information concerning its precursor and synthetic method. This information is useful for the prevention of smuggling methamphetamine and its precursor, and resultant reduction of methamphetamine abuse. In the present study, we investigated on the enantiomer ratios of 433 crystalline methamphetamine samples seized in Korea from 1994 to 2005. Excluding 17 samples of low purity, 416 samples were used for enantiomer profiling. The methamphetamine samples were derivatized with (S)-(+)-alpha-methoxy-alpha-(trifluoromethyl)phenylacetyl chloride ((S)-(+)-MTPACl), and the derivatives were analyzed by GCMS in selected ion monitoring (SIM) mode. The enantiomer ratios of the samples were calculated from the standard calibration curves of each enantiomer, both of which showed good linearity in the range of 0-1.2 microg. Most of the seizures were pure S(+)-enantiomer, but 21% (95 of 416 samples) contained R(-)-enantiomer above 1%. They began to appear from 1997, and increased continuously up to 50% in the year 2005 (55 of 111 samples). From this study, we could find out that alternative precursors have been used recently for the illicit manufacture of methamphetamine seized in Korea.  相似文献   

13.
Impurity profiles of methamphetamine tablets seized in Thailand have been investigated. The samples are extracted with small amounts of ethyl acetate under alkaline condition and the extracts are analyzed by capillary gas chromatography. Nine compounds (1,2-dimethyl-3-phenylaziridine, ephedrine, methylephedrine, N-formylmethamphetamine, N-acetylmethamphetamine, N-formylephedrine, N-acetylephedrine, N,O-diacetylephedrie, methamphetamine dimer) are identified as impurities in methamphetamine tablet. Caffeine and ethyl vanillin are also detected as diluents and/or adulterants, and acetylcodeine monoacetylmorphine and diacetylmorphine are contained in many samples. In addition, trans-3,4-dimethyl-5-phenyl-2-oxazolidone is newly found as an impurity. For characterization and comparison of methamphetamine tablet exhibits, intensely and commonly detectable nine peaks are selected as the factor for multivariate analysis. The procedures reported here permit classification of 250 analyzed exhibits into five groups and characterization of classified groups.  相似文献   

14.
Analysis of impurities in methamphetamine (MA) can be used to characterize MA seizures, investigate the relationship among MA seizures, and provide information on their synthetic routes. Recently, chemically derivatized MA, such as tert-butoxycarbonyl (t-Boc) MA, has been seized and attracted attention because routine forensic analysis methods may fail to correctly identify them. Chemical derivatization is a simple method for protection and deprotection of a compound, and protection of MA using t-Boc can be used to mask the MA. Although t-Boc derivatization might alter the impurity profile of MA, the actual changes in the impurity profile have not been investigated. In this study, changes in the MA impurity profile with tert-butoxycarbonylation were explored. MA and some typical impurities were derivatized using di-tert-butyl dicarbonate and water. Analysis of the impurities in five MA samples by gas chromatography showed that peaks both appeared and disappeared for the deprotected MA compared with the original MA. However, typical impurities important for characterizing MA seizures were conserved after derivatization and deprotection. Most of the new peaks were speculated to be contaminants introduced during derivatization and deprotection. A peak giving a mass spectrum similar to that of t-Boc MA was detected in the chromatograms of t-Boc MA and deprotected MA. Although the origin of this peak was not determined, it might be a marker for the MA involving tert-butoxycarbonylation. These results indicate that tert-butoxycarbonylation can alter the MA impurity profile; therefore, care is needed when interpreting results for derivatized MA.  相似文献   

15.
In this study fifty samples of crystalline methamphetamine obtained from antinarcotics police of Iran seized during the year 2010 were analyzed. In order to determine the chemical characteristics of these samples, anion test, Gas Chromatography-Mass Spectrometry (GC-MS) and Liquid Chromatography-Mass Spectrometry (LC-MS) were carried out on the samples. All of the samples containing methamphetamine tested positive for chloride anion. The range of methamphetamine hydrochloride content in these samples was 33-95%. One sample out of 50 contained no methamphetamine. The fact that 1,2-dimethyl-3-phenylaziridine was the most frequently found impurity in the analyzed samples, indicates that most of the methamphetamine samples seized in Iran have been synthesized from pseudoephedrine as starting material.  相似文献   

16.
The profiling of impurities in methamphetamine (MA) using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) is described. The extraction of the impurities with an SPME fiber was examined under varying conditions. Optimal chromatograms were obtained when a 50 mg MA sample at 85 degrees C for 30 min was extracted using a fiber coated with divinylbenzene/carboxen/polydimethylsiloxane. MA samples from nine different origins were analyzed under optimized extraction conditions. Compounds related to MA such as benzaldehyde, benzyl alcohol, amphetamine, benzyl methyl ketone, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, N-acetylamphetamine, N-acetylmethamphetamine and N-formylmethamphetamine were detected in the chromatograms. Trace amounts of ethanol, diethyl ether and acetic acid were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different, depending on the sample. After the areas of the eight principal peaks were converted to their square root and logarithm, similarities among the samples were evaluated by Euclidian distance, cosine distance and correlation coefficient. The results showed that a combination of logarithmic conversion and cosine distance was the most suitable for discriminating and classifying the samples. HS-SPME/GC-MS is a simple and effective method for the extraction and identification of impurities. The present method, in combination with an appropriate statistical analysis, would be useful for developing a profile of impurities in MA.  相似文献   

17.
Biological fluids and tissue extracts prepared according to a previously published method were passed through a column of Amberlite XAD-2 resin for removal of drugs. The differential elution of the adsorbed drugs from the resin was performed by sequential elution of the drugs in four steps. The column was first washed with 30 ml of 0.05M sodium acetate buffer, pH 4.55. Drugs exhibiting acidic or neutral characteristics were then eluted from the column with 100 ml of chloroform in 20-ml aliquots. The column was then washed with 30 ml of 0.1M potassium carbonate, which was discarded. Drugs exhibiting basic characteristics were then eluted from the column with 100 ml of chloroform:isopropanol (3:1) in 20-ml aliquots. Sensitivity of drug detection with this method by thin-layer chromatography was 0.5 mug/ml in a 10-ml sample for nearly all drugs tested.  相似文献   

18.
In this paper, miniaturized achiral and chiral high-performance liquid chromatographic procedures for the determination of methamphetamine and amphetamine in human urine are described. After a simple pretreatment of human urine (i.e., 10 microL of urine or diluted urine were acidified and dried-up under N2 at room temperature) and fluorescence derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)-benzoyl chloride under mild conditions (pH 9.0, 10 min at room temperature), the derivatives were isocratically separated on a semi-micro ODS column with Tris-HCl buffer (0.1 M, pH 7.0): acetonitrile (45 + 55 v/v) at a flow rate of 0.2 mL/min or their enantiomers were separated on a semi-micro OD-RH column with sodium hexafluorophosphate (0.3 M aq.): acetonitrile (44 + 56 v/v) at a flow rate of 0.1 mL/min as the mobile phase. Wide-ranged calibration curves were obtained with detection limits for the achiral and chiral analyses in the atto and femtomol levels, respectively, per injected volume. Satisfactory within- and between-day reproducibility data were obtained with both the methods with the highest relative standard deviation being 9.6%. The methods were applied to the determination of methamphetamine and amphetamine in human urine samples and the concentrations determined by the two methods were well correlated (r = 0.994).  相似文献   

19.
An analytical method to identify and determine dimethylamphetamine (DMA) and its metabolites in human urine was developed with liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) involving the direct injection of a urine sample. The urine samples were directly injected by using a gel permeation column, whose stationary phase was polyvinyl alcohol with a small amount of a carboxyl group, so DMA and its metabolites were analyzed rapidly and simply without pretreatment such as extraction, concentration and derivatization. DMA and its metabolites were identified in drug-free human urine spiked with 1 microg of DMA, dimethylamphetamine N-oxide (DMANO) and methamphetamine (MA), and 3 microg of amphetamine (AM) in 1 ml of urine under the full-scan mode. Under the selected ion monitoring (SIM) mode, the limits of detection (signal-to-noise ratio=5) for DMA, DMANO, MA and AM were 20, 20, 20 and 60 ng in 1 ml of urine, respectively. This method was applied to the identification and determination of DMA and its metabolites in urine samples of 10 DMA abusers. The concentrations of DMANO were higher than those of unchanged DMA in all urine samples; thus, DMANO is considered to be a useful metabolite as an indicator to prove DMA intake.  相似文献   

20.
A rapid, sensitive, accurate, precise, reproducible, and versatile method for determining the purity of reference drug standards and the routine analysis of illicit drugs and adulterants using proton (1H) Nuclear Magnetic Resonance (NMR) Spectroscopy is presented. The methodology uses a weighed sample dissolved in a deuterated solvent or solvent mixture containing a high purity internal standard. The NMR experiment employs 8 scans using a 45 second delay and 90 degrees pulse. In the determination of purity of reference standards, the number of quantitative determinations available is equal to the number of peak groups that are baseline resolved. The relative standard deviation (RSD) of these signals is usually < 1% for pure standards, and the results agree well with other purity determining methods. This method can also aid in the determination of correct molecular weight for standards containing an unknown number of waters of hydration or an unknown number of acids per drug in salts. Because the molar response for the hydrogen nucleus is 1 for all compounds, and since no separation media are used, only one linearity study is required to test a probe. In the presented study, the linearity of the NMR probe was determined using methamphetamine HCl dissolved in deuterium oxide (D2O) with maleic acid as the internal standard (5 mg) for a range of concentrations from 0.033 to 69.18 mg/ml with a resulting correlation coefficient of >0.9999 for all 6 methamphetamine peak groups. The spectra of complex illicit heroin, methamphetamine, MDMA, and cocaine samples are presented, as well as an extensive list of compounds, their solubilities and the solvent(s) and internal standard used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏