Luminol, leuchomalachite green, phenolphthalein, Hemastix, Hemident, and Bluestar are all used as presumptive tests for blood. In this study, the tests were subjected to dilute blood (from 1:10,000 to 1:10,000,000), many common household substance, and chemicals. Samples were tested for DNA to determine whether the presumptive tests damaged or destroyed DNA. The DNA loci tested were D2S1338 and D19S433. Leuchomalachite green had a sensitivity of 1:10,000, while the remaining tests were able to detect blood to a dilution of 1:100,000. Substances tested include saliva, semen, potato, tomato, tomato sauce, tomato sauce with meat, red onion, red kidney bean, horseradish, 0.1 M ascorbic acid, 5% bleach, 10% cupric sulfate, 10% ferric sulfate, and 10% nickel chloride. Of all the substances tested, not one of the household items reacted with every test; however, the chemicals did. DNA was recovered and amplified from luminol, phenolphthalein, Hemastix, and Bluestar, but not from leuchomalachite green or Hemident.  相似文献   

2.
Four presumptive blood tests, Hexagon OBTI, Hemastix(R), Leucomalachite green (LMG), and Kastle-Meyer (KM) were compared for their sensitivity in the identification of dried bloodstains. Stains of varying blood dilutions were subjected to each presumptive test and the results compared. The Hexagon OBTI buffer volume was also reduced to ascertain whether this increased the sensitivity of the kit. The study found that Hemastix(R) was the most sensitive test for trace blood detection. Only with the reduced buffer volume was the Hexagon OBTI kit as sensitive as the LMG and KM tests. However, the Hexagon OBTI kit has the advantage of being a primate specific blood detection kit. This study also investigated whether the OBTI buffer within the kit could be utilized for DNA profiling after presumptive testing. The results show that DNA profiles can be obtained from the Hexagon OBTI kit buffer directly.  相似文献   

3.
血迹是凶杀、伤害等案件中最常见和最重要的一种物证。血痕预试验是利用化学检测的方法从现场大量可疑的斑迹中初步筛选出可能是血的痕迹物证。本文对常用血痕预试验试剂的应用现状及其灵敏度、特异性、稳定性等进行分析比较,同时对预试验检测中存在的问题及今后的发展趋势进行综述,旨在为更好地研究、利用血痕预试验试剂提供参考。  相似文献   

4.
《Science & justice》2014,54(6):432-438
Current methods of detection and identification of blood stains rely largely on visual examination followed by presumptive tests such as Kastle–Meyer, Leuco-malachite green or luminol. Although these tests are useful, they can produce false positives and can also have a negative impact on subsequent DNA tests. A novel application of visible wavelength reflectance hyperspectral imaging has been used for the detection and positive identification of blood stains in a non contact and non destructive manner on a range of coloured substrates. The identification of blood staining was based on the unique visible absorption spectrum of haemoglobin between 400 and 500 nm. Images illustrating successful discrimination of blood stains from nine red substances are included. It has also been possible to distinguish between blood and approximately 40 other reddish stains. The technique was also successfully used to detect latent blood stains deposited on white filter paper at dilutions of up to 1 in 512 folds and on red tissue at dilutions of up to 1 in 32 folds. Finally, in a blind trial, the method successfully detected and identified a total of 9 blood stains on a red T-shirt.  相似文献   

5.
Presumptive tests for blood play a critical role in the examination of physical evidence and in the determination of subsequent analysis. The catalytic power of hemoglobin allows colorimetric reactions employing phenolphthalein (Kastle‐Meyer test) to indicate “whether” blood is present. Consequently, DNA profiles extracted from phenolphthalein‐positive stains are presumed to be from blood on the evidentiary item and can lead to the identification of “whose” blood is present. Crushed nodules from a variety of legumes yielded phenolphthalein false‐positive reactions that were indistinguishable from true bloodstains both in color quality and in developmental time frame. Clothing and other materials stained by nodules also yielded phenolphthalein false‐positive reactivity for several years after nodule exposure. Nodules from leguminous plants contain a protein (leghemoglobin) which is structurally and functionally similar to hemoglobin. Testing of purified leghemoglobin confirmed this protein as a source of phenolphthalein reactivity. A scenario is presented showing how the presence of leghemoglobin from nodule staining can mislead investigators.  相似文献   

6.
Saliva stains present a unique challenge in the forensic setting, often challenging the analyst to weigh the value of presumptive indication of the fluid versus the potential for DNA analysis to yield identification information. There are many situations in which determining the presence of a body fluid is probative and further corroborates DNA evidence. That said, even a minute portion of sample consumed by a screening test could mean the difference between a full, partial, or null profile obtained through DNA analysis. The basis of presumptive testing or screening of saliva has historically been based on the presence of amylase, a component found in relatively high concentrations in human saliva versus other body fluids and substances. Though the current available methods for the screening of saliva in a forensic application have grown in number, the popularity of these methods seemingly has not. This study attempts to identify a specific and sensitive saliva screening test by comparing three modern techniques--the recently released SALIgAE, Phadebas, and starch-iodine mini-centrifuge test--on the basis of sensitivity, specificity, mixtures, and simulated casework samples while also considering sample consumption. The Phadebas method for presumptive saliva testing detected dilutions of neat saliva down to 1:200 versus considerably less sensitive results with SALIgAE and the starch-iodine mini-centrifuge test. Utilizing a screening test with a high degree of sensitivity, such as Phadebas, allows an analyst to gain a maximum amount of information in the form of body fluid indication and DNA results because of the consumption of a small portion of sample.  相似文献   

7.
The purpose of this work was to conduct a comparative study of the sensitivity and specificity of phenolphthalein, tetramethylbenzidine, leucomalachite green, and orthotolidine as presumptive tests for blood. The findings of this study indicate that the phenolphthalein and the leucomalachite green tests are the most specific and that the tetramethylbenzidine and orthotolidine tests are the most sensitive of the group. The author concludes that the phenolphthalein test is the best single test for evaluating suspected bloodstains.  相似文献   

8.
In forensics, bloodstains on dark fabrics might be invisible for the naked eye. Although several visualization, presumptive, and confirmatory blood tests have been developed, all have one or more disadvantages, especially on DNA analysis. We report here the use of a visualization assay that can visually detect blood drops up to 1/20 dilution. In this assay, the fabric is placed between two wet filter papers and covered by glass surfaces on both sides. Pressure is applied on the glass surfaces in which bloodstains transfer onto the filter papers through capillary forces. Detected stains can be tested with other more sensitive presumptive blood tests performed on the filter paper. Even more, DNA analysis can be performed on the transferred bloodstains. The presented visualization assay is easy to perform, extremely cheap, requires little hands on time, and does not affect bloodstain pattern analysis.  相似文献   

9.
Detection of blood on dark materials is difficult for crime scene examiners so presumptive tests are used to assist. This study compared the ability of luminol, leuko crystal violet, tetramethylbenzidine, and Combur Test®E to detect whole, diluted blood (1:100) and a key‐shaped blood transfer stain (1:10), on dark cotton sheeting, tea towel, socks, synthetic carpet, and car mats. Powdered bleach was used to evaluate specificity of the blood detection tests. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall misclassification rate (OMR) assessed the quality of the blood tests. Luminol was the preferred test for diluted blood having the highest sensitivity (79%–96%), NPV (66%–93%), and the lowest OMR (3%–15%). Luminol was also found to be most efficient with a testing time on 25 items of 2 h 50 min compared with up to 8 h. Overall, luminol was the most effective method, also providing information on bloodstain patterns.  相似文献   

10.
When bloodstains are detected at crime scene using presumptive tests (e.g. luminol, phenolphthalein, leuchomalachite green), it is important to establish the real human nature of each stain. This is possible using confirmatory tests. One of these is rapid stain identification-blood (RISD-blood) a lateral flow immuno-chromatographic strip test format which allows the identification of human blood by detection of glycophorin A, a red blood cell membrane antigen, using two anti-human glycophorin A (GPA) monoclonal antibodies.The aim of this study is to assess the sensitivity of RSID-blood test in old, degraded bloodstains and in some bloodstains previously treated with BlueStar Forensic, a presumptive test which is often used in crime scene investigations to detect latent bloodstains. The genetic analysis of all bloodstains of confirmed human nature was subsequently performed using the AmpF1STR Identifiler PCR Amplification Kit (Applied Biosystems), to validate the possibility of obtain a consistent and reliable DNA typing results.  相似文献   

11.
This study was designed to test the following factors involved with processing luminol treated bloodstained evidence: 1) The reactivity of other presumptive chemical color tests, phenolphthalin (PT) and tetramethylbenzidine (TMB), following the application of the light emitting luminol presumptive test. 2) The effect of different cleanings of various bloody substrates on the luminol test. 3) The effect of different cleanings of various bloody substrates on the ability to obtain DNA suitable for PCR testing. 4) The ability to extract DNA from luminol treated bloodstained substrates using three extraction techniques. 5) The effect of spraying washed and unwashed bloodstains on various substrates with luminol on the ability to correctly type the DNA using PCR. Our findings indicated that luminol did not adversely effect the PCR testing and did not interfere with the PT and TMB presumptive tests for blood. It was determined that the substrate and the method of cleaning were the major factors affecting DNA yield and the ability to type the bloodstains using PCR based technologies.  相似文献   

12.
Abstract: The choice of reagents for presumptive tests for blood, and subsequent extraction methodologies, can significantly affect both the quantity and quality of purified DNA. Blood samples directly tested with Hemastix® yielded <1% of the DNA recovered from untested samples when purified using the Qiagen BioRobot® EZ1 and EZ1® DNA Investigator kit. Full short tandem repeat profiles were obtained from both tested and untested samples, suggesting that the Hemastix® reagent(s) affect DNA binding, rather than produce DNA damage. The Hemastix® inhibition of DNA yield could be overcome by the addition of MTL buffer to the sample prior to extraction. Laboratories may wish to modify current procedures for extracting blood samples, utilize other extraction/purification methodologies, or inform their submitting agencies to avoid direct exposure of questioned bloodstains to Hemastix® reagents.  相似文献   

13.
微滴式数字PCR技术用于生物样品种属鉴定和绝对定量   总被引:4,自引:0,他引:4  
目的 运用微滴式数字PCR技术进行生物样品的种属鉴定和绝对定量.方法 选择人mtDNA两个编码基因ND4和16S rRNA,设计特异性引物与探针,用人来源及常见动物样本验证种属特异性,再用重组质粒和2组共16份人来源生物检材,倍比稀释.使用微滴式数字PCR技术进行种属检验和绝对定量,验证其灵敏度和稳定性.结果 人重组质粒FAM (ND4)可进行人来源样品的检测,其检测结果与各级稀释梯度基本吻合,微滴式数字PCR技术可以检测出反应体系中低至单拷贝的DNA.结论 微滴式数字PCR技术可以进行生物样品的种属鉴定和绝对定量,并具有很高的灵敏度和特异性,可应用于日常法医物证检验.  相似文献   

14.
An investigation into the effects of physical and chemical enhancement on subsequent presumptive and confirmatory tests for human blood is presented. Human blood was deposited onto porous (white 80 gsm paper and brown envelope) and non-porous (tile and linoleum) substrates in a depletion series (30 depletions on non-porous and 20 on porous) and subjected to three ageing periods; 1, 7 and 28?days. A number of enhancement techniques were tested [fluorescence, black magnetic powder (BMP), iron-oxide black powder suspension (PS), cyanoacrylate (CA) fuming, acid violet 17 (AV17), acid yellow 7 (AY7), ninhydrin, DFO and Bluestar Forensic Magnum (BFM) luminol] to evaluate their potential effects on subsequent presumptive and confirmatory tests. AV17 and Bluestar provided the best enhancement and fully enhanced all depletions in the series. The sensitivity of the Kastle-Meyer (KM) (presumptive), Takayama and RSID-Blood tests (confirmatory) was initially investigated to determine the range of detectable depletions. The KM test detected all depletions, whereas the Takayama test detected up to depletion 6 and RSID-Blood detected up to depletion 20 (paper), 10 (envelope), 15 (tile) and 9 (lino). The abilities of these tests to detect blood after enhancement were then observed.A number of techniques resulted in little to no effect on any of the blood tests, whereas adverse effects were observed for others. Ninhydrin and CA fuming caused weak but instantaneous positive KM results whereas methanol-based AV17 and AY7 delayed the reaction by as much as 1?min. The Takayama test was not very sensitive, therefore, its performance was easily affected by enhancement and negative results were often observed. RSID-Blood tests were largely unaffected by chemical enhancement although a drop in positive results was observed for some of the techniques when compared to positive controls.Using a standard procedure for DNA extraction, all the tested blood samples (before and after enhancement) gave a detectable quantity of DNA and were successfully profiled. Out of the 45 samples processed for DNA profiling, 41 gave full profiles, while the remaining showed allele drop out in one or two loci.  相似文献   

15.
Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based presumptive screening tests such as acid phosphatase (AP), Phadebas, and luminol, often used in casework for detecting potential semen, saliva, and blood stains, respectively. The Polilight was able to locate stains that were not apparent to the naked eye. The color of the material on which a stain is deposited can have an effect on the detectibility of the stain. The Polilight was found to be comparable with the AP and Phadebas tests in terms of its sensitivity. In a comparative study between the AP test and Polilight on 40 casework exhibits, one false-negative result was observed when using the Polilight. On a series of mock casework exhibits it was determined that the Polilight can be used successfully to locate saliva stains for DNA analysis. The sensitivity of luminol for detecting potential bloodstains was greater than that of Polilight; however the Polilight has particular application in instances where a bloodstain may have been concealed with paint. Overall, the Polilight is a relatively safe, simple, noninvasive, and nondestructive technique suitable for use in forensic casework.  相似文献   

16.
Some of the commonly used presumptive test reagents for identification of blood and semen could potentially affect the recovery of intact high-molecular-weight deoxyribonucleic acid (DNA) from evidentiary samples. Thus, the capability of performing restriction fragment length polymorphism (RFLP) analysis on evidentiary samples could be compromised. In order to investigate the potential effects of presumptive test reagents on the DNA present in these samples, bloodstains on cotton and glass were exposed directly to luminol, benzidine, phenolphthalein, o-tolidine, and leucomalachite green, while semen stains and vaginal swabs containing semen were exposed directly to bromochloroindolyl phosphate (BCIP) and sodium thymolphthalein monophosphate (STMP) reagents. The yield gels for DNA quality and quantity and RFLP results indicated that bloodstains exposed to luminol, benzidine dissolved in ethanol, and phenolphthalein, as well as semen stains and vaginal swabs exposed to BCIP and STMP yield RFLP patterns consistent with that of the uncontaminated control. Except for the phenolphthalein treatment, the quantity of extractable, high-molecular-weight DNA obtained was comparable with that of untreated stains. Therefore, evidentiary material purposely or inadvertently contaminated with these reagents can be successfully typed. However, stains exposed to benzidine dissolved in glacial acetic acid, leucomalachite green, and o-tolidine failed to yield high-molecular-weight DNA or to produce any RFLP patterns.  相似文献   

17.
Quadratic pieces of fleece measuring 16 mm2 were soaked with 10 different blood-samples in the dilution steps of 1:1, 1:10, 1:100, 1:1000, respectively, and were tested in blood group typing and identification tests of forensic serology. The above spezified dilutions correspond with 5 microliters, 0.5 microliter, 0.05 microliter and 0.005 microliter of blood, respectively. The detection limit of the microspectrometric test for blood was the dilution 1:10, of the porphyrine test a dilution above 1:100, whereas the preliminary test for blood (peroxidase) succeeded always up to a dilution of 1:1000 and the species determination by the radial immunodiffusion test in agar gels succeeded in most cases op to a dilution of 1:1000. The detection limit of the anti-human globulin inhibition test was between the dilution steps 1:10 and 1:100 when non-titrated and undiluted anti-human globulin serum was used. Gc- and ABO-grouping were possible up to a dilution of 1:100 and were thus the most sensitive grouping systems. Phenotyping of the enzyme-systems and the Gm/Km-system usually required stains with considerably higher blood concentrations i.e. stains of undiluted blood.  相似文献   

18.
Microthermal method was used for objective registration of the course of precipitation reaction in determination of species specificity of human and animal protein. This method allows one to carry out species identification using blood protein dilution with 0.9% solution of natrium chloride in correlation from 1:100 up to 1:100,000. Method is simple in use, it can be operated on the apparatus of home production. Analysis with two control tests may be performed within 10 min. The results of reaction are successfully registered as thermistograms subjoined to the expert conclusion.  相似文献   

19.
Laux DL 《Science & justice》2011,51(3):143-145
Forensic scientists periodically check working test reagents with knowns or standards to verify that the presumptive testing reagents are working properly. Oftentimes, this is done with a neat body fluid such as blood or saliva that is dried onto a swab and kept in a freezer. The problem with this practice is that a degrading test reagent, for example acid phosphatase testing reagent, may test positive on a neat standard but miss a weak semen stain from a case.To ensure that presumptive testing reagents are working properly, a series of “weak” standards have been developed for the testing of acid phosphatase, amylase, creatinine and hemoglobin. The preparation and use of these biological standards will be discussed.  相似文献   

20.
Abstract:  Following implementation of our automated process incorporating the Promega DNA IQTM system as a DNA extraction method, a large number of blood-containing exhibits failed to produce DNA. These exhibits had been tested with the Hemastix® reagent strip, commonly used by police investigators and forensic laboratories as a screening test for blood. Some exhibits were even tainted green following transfer of the presumptive test reagents onto the samples. A series of experiments were carried out to examine the effect of the Hemastix® chemistries on the DNA IQTM system. Our results indicate that one or more chemicals imbedded in the Hemastix® reagent strip severely reduce the ability to recover DNA from any suspected stain using the DNA IQTM magnetic bead technology. The 3,3',5,5'-tetramethylbenzidine (TMB) used as the reporting dye appears to interact with the magnetic beads to prevent DNA recovery. Hydrogen peroxide does not seem to be involved. The Hemastix® chemistries do not interfere in any way with DNA extraction performed using phenol-chloroform. The incompatibility of the Hemastix® chemistries on the DNA IQTM system forced us to adopt an indirect approach using filter paper to carry out the presumptive test.  相似文献   