首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 61 毫秒
1.
Five DNA extraction systems were assessed for their DNA extraction efficiency on samples of fresh pig bone. Four commercially available silica-based extraction kits (ChargeSwitch® gDNA Plant Kit (Life Technologies), DNA IQTM System Kit (Promega), DNeasy® Blood & Tissue Kit (Qiagen) and PrepFiler® BTA Forensic DNA Extraction Kit (Life Technologies)) and a conventional phenol-chloroform method were tested in this study. Extracted DNA samples were quantitated with GoTaq® qPCR Master Mix (Promega) using an Applied Biosystems® 7500 Real-Time PCR System and the extracts were amplified using an in-house multiplex system. The phenol-chloroform extraction produced higher yields of DNA than the silica-based extraction methods. Among the silica-based extractions ChargeSwitch® gDNA Plant Kit recovered the highest amounts of DNA. However, all methods produced DNA that could be amplified and none of the extracts contained any detectable inhibition.  相似文献   

2.
The efficacy of two extraction methods; room temperature and heat protocols was assessed for buccal swabs using the Prep-n-Go™ Buffer. DNA was extracted from buccal swabs using both extraction methods and their effectiveness to produce good quality DNA profiles was evaluated. Heat protocol was found to yield more DNA, however room temperature protocol produced better quality DNA profiles with fewer artefacts when the samples from both extraction methods were amplified directly without any normalisation with the VeriFiler™ Express PCR Amplification Kit.  相似文献   

3.
Analysis of STR profiles obtained from touch DNA has been very useful to the elucidation of crimes. Extraction method may be determinant for the recovery of genetic material collected from different surfaces. Vehicle theft is one of the most common crimes in São Paulo city, Brazil, but collection of biological traces in car steering wheels is not considered, because of the belief that profiles generated won’t be able to identify the thief, only the owner. This study aimed to analyze the efficacy of extraction methods for obtaining DNA profiles in samples collected from steering wheels. Eight criminal acts were simulated with 2 different individuals each (mixture of victim and thief), in duplicate, in order to compare two extraction methods: DNA IQ™ and Casework Direct Kit (both Promega Corporation). Genetic material was collected by double swab method and quantified by Quantifiler™Trio (ThermoFisher Scientific). Amplification was conducted with PowerPlex® Fusion System (Promega). It was possible to obtain STR profiles for all experiments. The mixtures were compared with reference profiles to evaluated how many alleles of each donor were observed. Samples extracted with Casework Direct Kit obtained STR profiles with higher averages of alleles for primary and secondary donors (88.7% and 59.9%, respectively) than those extracted with DNA IQ™ (60.4% and 38.1%, respectively). This could be explained by the differences established in the protocols of both methods, since DNA IQ™ is based on successive washes and can result in loss of DNA, whereas Casework Direct Kit minimizes this problem. We concluded that Casework Direct Kit was more efficient for processing touch DNA samples than DNA IQ™.  相似文献   

4.
Disputes over the identity of a urine sample donor have been reported, and urine authentication by genetic profiling has helped resolved the cases. However, since genotyping of urine is not always required, many drug-testing laboratories may face sample storage issues. Several studies have investigated the use of FTA® cards as a convenient tool for keeping specimen at room temperature for extended periods of time. However, generating complete STR profile from some FTA®-deposited urine samples remains challenging due to low levels of genetic material content, necessitating amendments to the laboratory’s standard protocols. This work therefore aims to evaluate the effects of two DNA template preparation methods, both employing FTA® cards as the storage medium, on the success rates of STR profiling from urine. Specimen from a female volunteer, representing a particularly low-yield sample, was employed. Aliquots of 1 and 2 mL were used as the starting material to evaluate DNA template preparation using the FTA® manufacturer’s protocol for disc purification against elution of DNA from the FTA® using Prepfiler™ Forensic DNA Extraction Kit. AmpFSTR™ Identifiler™ Plus PCR Amplification Kit was used to amplify the STR markers, and the PCR products were analysed using Applied Biosystems™ 3500xL Genetic Analyzer. The DNA profile qualities were examined in terms of number of loci detected and peak height balance. Comparisons with the profiles obtained from DNA isolated using QIAamp® DNA Micro Kit from 1 and 2 mL of the same batch of urine were also made. The optimised protocol was then tested on urine samples from three male volunteers. The results showed that the purification of FTA® punches according to the manufacturer’s protocol enabled full DNA profiles to be obtained from both 1 and 2 mL of urine from all samples tested, including male samples. In contrast, no DNA profile could be generated from the DNA eluted with the Prepfiler™ kit. When compared with the more conventional solid-phase DNA extraction method, the profiles generated from the FTA® punches exhibited similar reproducibility and quality to those from the template isolated by the QIAamp® Kit. This work further demonstrated the feasibility of FTA® cards as a tool for specimen storage and DNA template preparation from small volumes of urine for authentication by STR profiling. Full STR profiles could be generated from sample from both sexes without modification of the PCR conditions or injection time.  相似文献   

5.
4种固相颗粒吸附法提取滤纸血痕DNA效果的比较   总被引:1,自引:0,他引:1  
目的探讨4种固相颗粒吸附法提取滤纸血痕样本DNA的效果。方法含有1μL静脉血的滤纸血痕180份,分为4组,每组45份。分别采用4种固相颗粒吸附法(DNAIQ~(TM)系统、D盾超敏DNA提取试剂盒、超高效硅珠纯化DNA提取试剂盒和常规的硅珠法)对上述样本进行DNA提取,对比各组DNA溶液的浓度及STR分型检验结果。结果 D盾超敏DNA提取试剂盒[(3.764±1.790)μg/mL]、超高效硅珠纯化DNA提取试剂盒(3.634±1.112)及常规硅珠法(3.350±1.250)提取到DNA溶液的浓度无统计学差异(P0.05),但均高于DNA IQ~(TM)系统(1.864±1.207)(P0.001);D盾超敏DNA提取试剂盒、超高效硅珠纯化DNA提取试剂盒及常规硅珠法样本图谱峰高大于DNA IQ~(TM)系统(P0.001),超高效硅珠纯化DNA提取试剂盒和常规硅珠法样本图谱峰高大于D盾超敏DNA提取试剂盒(P0.01)。结论 D盾超敏DNA提取试剂盒、超高效硅珠纯化DNA提取试剂盒及常规硅珠法对于滤纸血痕的DNA提取效率高于DNA IQ~(TM)系统;超高效硅珠纯化DNA提取试剂盒和常规硅珠提取到的DNA溶液可能具有更高的质量。  相似文献   

6.
DNA IQ磁珠法结合Maxwell~(TM) 16自动仪提取接触DNA   总被引:1,自引:0,他引:1  
目的研究DNA IQ磁珠法结合MaxwellTM 16自动仪对接触DNA提取的应用价值。方法 151份案件接触DNA检材95℃裂解后,采用DNA IQ磁珠法结合MaxwellTM 16自动仪提取DNA,然后进行DNA定量和STR分型检测,统计各种类型的接触DNA含量I、PC CT值和STR分型成功率。结果 151份案件接触DNA检材中,除果核平均DNA获得量为9.51ng以外,其它接触检材的平均DNA获得量均大于10ng,烟蒂检验成功率最高为93%,果核检验成功率较低,为60%。所有DNA样品的IPC CT值均在27左右,纯度高。结论大部分接触DNA检材采用DNA IQ磁珠法结合MaxwellTM 16自动仪可提取到足以进行STR分型的DNA。  相似文献   

7.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

8.
The use of the polymerase chain reaction (PCR) to define deoxyribonucleic acid (DNA) types at several loci was investigated. PCR was used to amplify nine short tandem repeat (STR) loci along with the amelogenin locus on the X and Y chromosomes using the AmpF/STR Profiler Plus PCR amplification kit (Perkin Elmer). Rib bones were collected from 12 individuals. Five cm portions were buried at a depth of approximately 30 cm and 5 cm portions were left on the surface of the ground. Samples were exposed to the environment for periods of time ranging from two weeks to 17 months. Dried blood standards were prepared for use as reference standards for each rib sample. Bone, muscle, and bone marrow were collected from each sample. DNA from each tissue type was extracted. Complete profile results were obtained from the surface bone samples out to an exposure time of 17 months. None of the muscle or bone marrow samples produced complete profile results beyond eight weeks. All DNA typing results from complete or incomplete profiles were consistent with DNA typing results of the corresponding blood standard. Results suggest that using the AmpF/STR Profiler Plus PCR Amplification Kit is a valid way to establish the DNA profile of tissue types from human remains.  相似文献   

9.
The onus of proof in criminal cases is beyond any reasonable doubt, and the issue on the lack of complete internal validation data can be manipulated when it comes to justifying the validity and reliability of the X-chromosomal short tandem repeats analysis for court representation. Therefore, this research evaluated the efficiency of the optimized 60% reduced volumes for polymerase chain reaction (PCR) amplification using the Qiagen Investigator® Argus X-12 QS Kit, as well as the capillary electrophoresis (CE) sample preparation for blood samples on Flinder's Technology Associates (FTA) cards. Good-quality DNA profile (3000–12,000 RFU) from the purified blood sample on FTA card (1.2 mm) were obtained using the optimized PCR (10.0 μL of PCR reaction volume and 21 cycles) and CE (9.0 μL Hi-Di™ Formamide and 0.3 μL DNA Size Standard 550 [BTO] and 27 s injection time) conditions. The analytical and stochastic thresholds were 100 and 200 RFU, respectively. Hence, the internal validation data supported the use of the optimized 60% reduced PCR amplification reaction volume of the Qiagen Investigator® Argus X-12 QS Kit as well as the CE sample preparation for producing reliable DNA profiles that comply with the quality assurance standards for forensic DNA testing laboratories, while optimizing the analytical cost.  相似文献   

10.
STR profiling using hard tissues obtained from a severely decomposed body is sometimes a laborious work. There is now on a market a new DNA extraction kit, PrepFiler™ Forensic DNA Extraction Kit (AppliedBiosystems), and we tested it for missing persons. Postmortem intervals ranged from weeks to several years. Fifteen bone fragments and eleven nails were used in this report. Genomic DNA was quantified by QuantiFiler® DUO Quantification Kit (AppliedBiosystems), and STRs were analyzed using AmpFlSTR® Identifiler® PCR Amplification Kit (AppliedBiosystems). The profiling of 16 STR loci was successful in all nail samples. However, STR profiling was successful in only 6 of 15 bone materials. Nine cases failed to analyze STR polymorphisms using another DNA extraction kit, the QIAamp DNA Mini Kit (QIAGEN). For bone samples, it seems that STR profiling depends on the quality of samples.  相似文献   

11.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

12.
《Science & justice》2021,61(4):339-344
When a body is decomposed, hard tissues such as teeth may provide the only DNA source for human identification. There is currently no consensus as to the best DNA extraction method, and there is a lack of empirical data regarding tooth morphotype and condition that may impact DNA recovery. Therefore, this study sought to investigate which variables significantly improved DNA concentration, integrity and profiling success. A total of 52 human teeth were assessed, representing all tooth morphotypes from three deceased individuals. DNA was extracted using both the QIAamp® DNA Investigator Kit and the phenol-chloroform method. DNA concentration and degradation index were assessed using real time PCR, prior to conventional DNA profiling. Contrary to international guidelines promoting the use of molars, DNA profiling from molars was the least successful, with premolars, followed by canines, performing the best. The presence of fillings reduced the DNA quantity and quality obtained and may explain the poor performance of molars. DNA from the maxillae were significantly less degraded when the QIAamp® was used, although this did not influence DNA profiling success. A significant increase in DNA concentration, integrity and profiling success was observed in diseased teeth (periodontitis) compared to those without disease. This may be due to increased white blood cell presence at the site. There was no significant difference in DNA profiling success between the two DNA extraction methods. However, different teeth yielded failed DNA profiles for each extraction method, suggesting that repeated attempts, using alternative DNA extraction methods, is recommended. The recovery of additional DNA profiling information from degraded samples may help to ultimately reduce the burden of unidentified human remains.  相似文献   

13.
《Science & justice》2019,59(4):411-417
The RapidHIT™ 200 device from IntegenX® provides a sample-to-profile platform that is capable of processing a variety of sample types. In this study we review the sensitivity of the ‘Run Other’ protocol for processing crime stain type samples containing various input quantities of DNA using the AmpFℓSTR® NGMSElect™ Express PCR Amplification Kit cartridges available from IntegenX®. The range of DNA inputs which achieved useable results were not as desired and therefore various enhancements to the instruments extraction processes were investigated. These studies showed an improvement in the range of DNA input templates that could by processed on the RapidHIT™ 200 by using the enhanced methods and resulted in three new run protocols.  相似文献   

14.
Calcified tissues, such as bone and tooth, and some other sample types, such as those containing adhesive, present a challenge to standard extraction protocols. We have developed a lysis reagent, BTA™ lysis buffer, which is designed for use with PrepFiler™ Kit reagents. The BTA™ lysis buffer disrupts calcified tissue matrices and achieves effective extraction of DNA from pulverized bone and tooth samples. In addition, the BTA™ lysis buffer mildly but efficiently extracts DNA from challenging substrates like tape, chewing gum, and cigarette butts and, as with bone and tooth, DNA from these lysates is purified using established PrepFiler™ reagent extraction protocols.We successfully extracted DNA from powdered human bone samples, chewed gum and smoked cigarettes using BTA™ lysis buffer. Extraction yields for bone, gum and cigarette samples tested were consistent and reproducible. This extraction method efficiently removed potential PCR inhibitors from all samples tested, and CT values for the internal PCR control of Quantifiler® Human DNA Quantification Kit were consistent and within the normal range. The DNA extracted from these samples also provided conclusive profiles that were free of PCR artifacts when amplified using the AmpF?STR® Identifiler® PCR Amplification Kit. The protocol is easily adapted for automation.  相似文献   

15.
Sex determination is of paramount importance in forensic anthropology. Numerous anthropological methods have been described, including visual assessments and various measurements of bones. Nevertheless, whatever the method used, the percentage of correct classification of a single bone usually varies between 80% and 95%, due to significant intra- and inter-population variations, and sometimes variations coming from secular trends. DNA is increasingly used in a forensic context. But forensic DNA extraction from bone raises several issues, because the samples are very often badly altered and/or in very small quantity. Nuclear DNA is difficult to get from degraded samples, according to low copy number, at least in comparison with mitochondrial DNA. In a forensic context (as in a paeleoanthropological context) DNA sex determination is usually complicated by the weak amount of DNA, the degraded nature of nucleic acids, the presence of enzymatic inhibitors in DNA extracts, the possible faint amplification of Y band and the risk of contamination during either excavation or manipulation of samples.The aim of this work was to compare three methods of DNA sex determination from bones: procedure #1 using a single PCR amplification, procedure #2 using a double PCR amplification, and procedure #3 adding bleaching for decontamination of the bone, instead of simply rubbing the bone. These processes were applied to samples of bones (49 samples coming from 39 individuals) that were in various states of post mortem alteration.The main results are the following. (i) No DNA could be extracted from three skulls (parietal bones, mastoid process), the compact bone of one rib, and the diaphysis of one femur; (ii) there was a contamination in three skulls; and (iii) the Y band did not appear in two male cases, with one of the three procedures (male tibia, procedure #2) and with procedures #2 and #3 (male femur).This study emphasises the main issue while working with altered bones: the impossibility to extract DNA in some cases, and, worth of all, the contamination of the sample or the faint amplification of Y band which leads to a wrong sex answer. Multiple and significant precautions have to be taken to avoid such difficulties.  相似文献   

16.
Chelex法和两种磁珠法提取接触DNA效果的比较   总被引:1,自引:0,他引:1  
目的比较Chelex法、DNA IQ磁珠法、EQ国产磁珠法对接触DNA的提取效果。方法将稀释为10ng、100ng的标准品DNA,分别采用Chelex法、DNA IQ磁珠法、EQ国产磁珠法处理;对30例烟蒂和30例牙刷分别采用Chelex法、DNA IQ磁珠法和EQ国产磁珠法提取DNA,然后进行PCR定量和STR检测。结果Chelex法对DNA的提取无损失,DNA IQ磁珠法、EQ国产磁珠法对DNA的提取均有不同程度的损失;烟蒂、牙刷等检材采用Chelex法提取的接触DNA量和IPC CT值显著高于IQ磁珠法、EQ国产磁珠法,但STR检验成功率却低于IQ磁珠法、EQ国产磁珠法。2种磁珠法提取的DNA量、IPC CT值和STR检验成功率无显著性差异。结论污染轻、杂质少的接触DNA检材,用Chelex法提取最为方便快捷;IQ磁珠法、EQ国产磁珠法更适合污染接触DNA检材的提取及自动化操作。  相似文献   

17.
With the aim to asses the efficiency of the DNA IQ System in the recovery of DNA from semen samples, cotton swabs were prepared from 1/5 serial dilutions of semen. Each swab was fractionated in four equivalent quarters and the DNA was further extracted following the differential lysis protocol. The recovered DNA was quantified by means of real time PCR and the average DNA yield was used to compare results. Direct extractions of equivalent aliquots of each semen dilution were used as reference samples. Even though a high percentage of the starting material was lost during the process of transfer to/recover from the solid support, our experimental results demonstrated that the DNA IQ system was able to detect around 103 sperm cells in the starting material, enabling to obtain a complete DNA profile with AmpFl STR IdentiFiler PCR Amplification Kit (Applied Biosystems).  相似文献   

18.
Since the beginning of our work in 2003 our laboratory has focused exclusively on STR DNA from bone, a powerful tool in missing person cases. In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, recovered from water, degraded, and/or contain inhibitory substances. To address these challenges, this study has evaluated the performance of relatively new STR kits Investigator® 24plex QS kit (Qiagen) and GlobalFiler™ PCR Amplification kit (Thermo Fisher Scientific) by comparing it with current uses of the AmpFLSTR® Identifiler® Plus kit (Applied Biosystems) to obtain genetic information from skeletal remains. We analyzed 20 bone samples of skeletal remains from routine casework submitted for body identifications by law enforcement corresponding using Investigator® 24plex QS kit and GlobalFiler™ PCR Amplification kit, previously analysed AmpFLSTR® Identifiler® Plus kit (Thermo Fisher Scientific). The data indicates that the STR profiles obtained using the GlobalFiler™ and Investigator® 24plex QS kit for analysis of skeletal remains has shown results in an increased number of reportable genetic loci, and provide greater power of discrimination in comparison to the Identifiler® Plus Kit. Advanced extraction and purification techniques, together with more sensitive and robust new amplification kits allowed us to overcome the challenges associated with processing compromised skeletal remains and ultimately obtain full STR DNA profiles in 99% of the bones.  相似文献   

19.
When using non-FTA cards in commercial multiplex STR kits for direct PCR, pretreatment steps with specific buffers are recommended. Here, we designed a rapid direct PCR method utilizing a non-FTA card, Oral Cell Sampling Kit, by omitting the pretreatment step involving Prep-n-Go™ Buffer, and it showed compatibility with the GlobalFiler™ Express PCR Amplification Kit, GlobalFiler™ PCR Amplification Kit, and PowerPlex® Fusion system. To optimize the PCR conditions, we tested the method with different final PCR volumes and cycles. Finally, we conducted a performance test using 50 Korean buccal samples and confirmed the high performance of the method, detecting more than 90% of the samples with full profiles when using GlobalFiler™ PCR Amplification Kit and PowerPlex® Fusion system at 29 cycles in a 10 μL final PCR volume. Thus, we report a simple direct PCR set-up to analyze reference samples collected using a non-FTA card manufactured in Korea.  相似文献   

20.
Successful DNA-based identification of mass disaster victims depends on acquiring tissues that are not highly degraded. In this study, multiple protocols for field preservation of tissues for later DNA analysis were tested. Skin and muscle samples were collected from decaying pig carcasses. Tissues were preserved using cold storage, desiccation, or room temperature storage in preservative solutions for up to 6 months. DNA quality was assessed through amplification of successively larger segments of nuclear DNA. Solution-based storage, including a DMSO/NaCl/EDTA mixture, alcohols, and RNAlater preserved DNA of the highest quality, refrigeration was intermediate, and desiccation was least effective. Tissue type and extent of decomposition significantly affected stored DNA quality. Overall, the results indicate that any tissue preservation attempt is far superior to delaying or forgoing preservation efforts, and that simple, inexpensive methods can be highly effective in preserving DNA, thus should be initiated as quickly as possible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号