首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
建立生物试样中常见巴比妥类药物的固相提取和柱上衍生化GC/MS分析法。将预制的血或肝分别在pH6.0和pH2.2的条件下过预活化的GDX-403吸附小柱,再用缓冲浪和蒸馏水各4ml顺序洗柱。最后用4ml丙酮/氯仿(1:1)溶剂洗脱样品,离心弃除水相,80℃挥至近干,用50μl乙醇定溶、取净化的样品2~4μl挥至近干,加20μl0.2molTMAH衍生化试剂,直接进样0.5μl,柱上衍生化GC/MS(GC)分析。在试验条件下,当血和肝分别添加2.0μg和5.0μg混合药物,回收率≥80%,相对标准差(RSD)优于±10%,检测限优于5ng(信/噪比≥2)。该法能有效地排除类脂物和组胺的干扰,可用于治疗量级药物分析和婴幼儿中毒案检验。  相似文献   

2.
The method of clonidine identification in blood and urine is described. It is based on liquid-liquid extraction and purification with toluol, subsequent derivation with pentafluobenzoylchloride and test on gas chromatograph with a detector of electron capture. The method is proposed for expert examinations.  相似文献   

3.
目的建立血中氟乙酸类杀鼠剂衍生化-液相色谱-电喷雾离子阱质谱分析方法。方法血样经乙腈沉淀蛋白后离心,上清液中加入衍生化试剂α-溴苯乙酮和催化剂四丁基溴化铵,在60℃水浴中加热90min,衍生化产物直接进行液相色谱-电喷雾离子阱质谱联用分析。结果血中氟乙酸根浓度在0.15μg/mL~15.40μg/mL之间具有良好的线性关系,最低检出限为0.020μg/mL。结论本文建立的方法操作简便、灵敏、快速,适用于刑事案件中氟乙酸类杀鼠剂的快速检验。  相似文献   

4.
芬氟拉明和苯丙胺类兴奋剂的固相微萃取   总被引:6,自引:1,他引:5  
用固相微萃取技术从血中提取芬氟拉明、苯丙胺和甲基苯丙胺。在 70℃条件下用 10 0 μm聚二甲基硅氧烷萃取头吸附 15min。重氢甲基苯丙胺作内标 ,采用柱前衍生化的进样方式 ,气质联用仪测定。选择离子m /z2 6 8(芬氟拉明 )、m/z2 40 (苯丙胺 )、m /z2 5 4(甲基苯丙胺 )和m/z2 5 8(重氢甲基苯丙胺 ,内标 )的峰面积比定量。血中检测浓度可达 0 0 1~ 0 0 3μg/g。通过解剖例中芬氟拉明的实际测定 ,证明这是一个从血液中提取分析苯丙胺类衍生物的快速准确的方法  相似文献   

5.
Aminoindanes are a class of novel psychoactive substances (NPSs) that have become more prevalent over the past decade. GC–MS is often utilized for identifying seized drugs and is well regarded for its ability to separate mixtures. However, certain aminoindanes have similar mass spectral data and require specific gas chromatographic stationary phases for separation. Derivatization is an alternative method that can be applied to GC–MS to enhance chromatographic results, providing more selective analysis in seized-drug identification. This study investigates derivatization techniques to provide options for forensic science laboratories in accurately identifying aminoindanes. Three derivatization reagents, N-methyl-bis(trifluoroacetamide) (MBTFA), heptafluorobutyric anhydride (HFBA), and ethyl chloroformate (ECF) were evaluated for the analysis of eight aminoindanes by GC–MS using two common gas chromatographic stationary phases, Rxi®-5Sil MS and Rxi®-1Sil MS. All three derivatization methods successfully isolated eight aminoindanes, including the isomers 4,5-methylenedioxy-2-aminoindane (4,5-MDAI), and 5,6-methylenedioxy-2-aminoindane (5,6-MDAI) that could not be differentiated prior to derivatization. Reduced peak tailing and increased abundance were observed after derivatization for all the compounds, and mass spectra of the derivatives contained individualizing fragment ions that allowed for further characterization of the aminoindanes. This excluded 4,5-MDAI and 5,6-MDAI as they shared the same characteristic ions and were only distinguishable by their retention times. All three derivatization techniques used in this study allow for successful characterization of the aminoindanes and give forensic science laboratories flexibility in their analysis approach when they encounter these compounds.  相似文献   

6.
A simple and sensitive method for the simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood was developed using a headspace-solid phase microextraction (SPME) and derivatization. A 0.5 g whole blood sample, 5 microl d(5)-methamphetamine (50 micrig/ml) as an internal standard, and 0.5 ml sodium hydroxide (1 M) were placed into a 12 ml vial, and sealed rapidly with a silicone septum and an aluminum cap. Immediately after the vial was heated to 70 degrees C in an aluminium block heater, the needle of the SPME device was inserted through the septum of the vial, and the extraction fiber was exposed in the headspace for 15 min. First, heptafluorobutyric anhydride was injected into the injection port of the GC-MS, and the compounds extracted by the fiber were then desorbed and derivatized simultaneously by exposing the fiber in the injection port. The calibration curves, using an internal standard method, demonstrated good linearity throughout the concentration range from 0.01 to 1.0 microg/g. The detection limits of this method were 5.0 ng/g for fenfluramine and methamphetamine, and 10 ng/g for amphetamine. No interferences were found, and the time for analysis was about 30 min for one sample. This method was applied to a suicide case in which the victim ingested fenfluramine. Fenfluramine was detected in the blood sample collected from the victim at the concentration of 7.7 microg/g.  相似文献   

7.
目的采用水相催化衍生化-液相色谱-紫外/荧光检测分析法,检测血中氟乙酸类杀鼠剂。方法血样经乙腈沉淀蛋白后,加入衍生化试剂4-溴甲基-7-甲氧基香豆素、催化剂四丁基溴化铵,在80℃水浴中衍生化反应120min,衍生产采用液相色谱-紫外/荧光检测分析。结果紫外检测法:氟乙酸根浓度在0.38~38.50μg/mL之间线性关系良好,最低检出限为0.10μg/mL;荧光检测法:氟乙酸根浓度在0.15~15.40μg/mL之间线性关系良好,最低检出限为0.050μg/mL。结论水相催化衍生化-液相色谱-紫外/荧光检测分析方法具有较好的灵敏度、准确性和精密度,可用于实际案例检测。  相似文献   

8.
The forensic toxicology community has recognized flunitrazepam and its metabolite (7-aminoflunitrazepam) as compounds of concern for several years. In this procedure, the analytes were extracted from whole blood and urine onto single mode solid phase cartridges (butyl) using nitrazepam as an internal standard. The columns were washed with distilled water and hexane. All three compounds were eluted from the sorbent using an ethyl acetate-methanol solvent mixture. After collection and evaporation of the solvent, the residue was dissolved in A, 0.1% (v/v) aqueous trifluoroacetic acid for HPLC-PDA analysis or B, ethyl acetate for derivatization with pentafluoropropionic anhydride (PFPA) for analysis by gas chromatography-mass spectrometry (selected ion monitoring, SIM). A limit of quantitation for this method using HPLC-PDA was found to be 5 and 1.0 ng mL(-1) by SIM.  相似文献   

9.
A simple determination method of amphetamine (AP) and methamphetamine (MA) in human blood was developed using on-column derivatization and gas chromatography-mass spectrometry (GC-MS). AP and MA were adsorbed on the surface of Extrelut and then derivatized the N-propoxycarbonyl derivatives using propylchloroformate. Pentadeuterated MA was used as an internal standards. The recoveries of AP and MA from the spiked blood were 89.7 and 90.3%, respectively. The calibration curves showed linearity in the range of 12.5-2000 ng/g for AP and MA in blood. The coefficients of variation of intraday and interday were 0.42-4.58%. Furthermore, this proposed method was applied to some medico-legal cases of MA intoxication. MA and its metabolite AP were detected in the blood samples, and the correlation of the blood level of amphetamines and the behaviors of the victims was in good agreement with the criteria proposed by Nagata [Jpn. J. Legal Med. 37 (1983) 513].  相似文献   

10.
There have been reports on improved chromatographic parameters derived from the incorporation of sequential derivatization in preparing biological specimens for the analysis of opiates. This current study was designed to characterize the mass spectrometric data resulting from sequential derivatizations of commonly abused amphetamines (along with all commercially available deuterated analogs) containing two active sites, i.e., amphetamine, methylenedioxyamphetamine, phenylpropanolamine. The first derivatization groups included in this study were trifluoroacetyl, pentafluoropropionyl, and heptafluorobutyryl, while t-butyldimethylsilyl was used as the second derivatization group. Products resulting from the first step and the two-step derivatization processes were analyzed by GC-MS. Full-scan mass spectrometric data were used to select ions with potential for designating the analytes and their respective isotopically labeled analogs in quantitative analysis protocols. Selected ion monitoring data were then collected and assessed to determine the quality of these ions when one or two different derivatization groups were incorporated in the sample preparation processes. A total of 77 full-scan mass spectra and 8 ion intensity cross-contribution tables, representing various forms of derivatization and isotopic analogs of the three amphetamines, are systematically presented for reference. Evaluations of these data concluded that many, but not all, products derived from "double derivatization" (sequential derivatization with two derivatization groups), generate ions of higher quality than those derived from "single derivatization".  相似文献   

11.
体液中常见滥用药物的系统筛选分析   总被引:6,自引:1,他引:5  
本文建立了体液中常见滥用药物的筛选分析体系.尿液或血液经固相萃取(SPE)或液提取(LLE)后,直接用GC/NPD分析或经TFA、BSTFA衍生化后用GC/MS分析.方法适用于同时分析甲基苯丙胺、MDMA、度冷丁、去甲度冷丁、曲马多、美沙酮、EDDP、可卡因、苯甲酰芽子碱、可待因、安定、氯丙嗪、吗啡、单乙酰吗啡等十四种常见滥用药物及代谢物.SPE法和LLE法回收率分别为66~102%和50~86%,最低检出限为2-5ng/ml尿.涉毒案件的鉴定应用表明该分析方法简便、快速、可靠.  相似文献   

12.
A derivatization/solid phase microextraction (SPME) method for the determination of benzoylecgonine in urine was developed. The derivatization is conducted directly in 1 mL of urine while sonicating for 3 min with 12 microL of hexyl chloroformate and 70 microL of a mixture containing acetonitrile:water:hexanol:2-dimethylaminopyridine (5:2:2:1 v/v), yielding benzoylecgonine hexyl ester (BHE) as the product. After the 3 min period, an aliquot of 250 microL is transferred to a vial for SPME. After the desired extraction time the 100 microns polydimethylsiloxane SPME fiber was transferred to the GC-MS for separation and analysis with a quadrupole ion trap mass spectrometer. The hexyl chloroformate derivatization and SPME procedures were optimized for compatibility and sensitivity. The method was found linear for 0.10 to 20.0 micrograms/mL (r2 = 0.999) of benzoylecgonine in urine using benzoylecgonine-d3 as an internal standard (1.5 micrograms/mL). Intra-day precisions were 8.8 and 6.8% RSD for 0.30 microgram/mL and 17 micrograms/mL benzoylecgonine standards in urine (n = 6), respectively. Inter-day precision (n = 3) were < or = 3.3% RSD, indicating good reproducibility. A detection limit of 0.03 microgram/mL (S/N = 3) was achieved, thus making the SPME method a simplified alternative to SPE for GC-MS confirmation after EMIT tests for benzoylecgonine which have a cutoff of 0.30 microgram/mL. Quantitative results by SPME and SPE of two clinical urine specimens known positive for cocaine by EMIT were in excellent agreement. Benzoylecgonine was detected by the derivatization/SPME method in 22 out of 22 other urine specimens known positive for cocaine.  相似文献   

13.
A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.  相似文献   

14.
A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).  相似文献   

15.
目的筛选适合于苯丙胺类气相色谱分析的衍生化试剂,同时寻找最佳衍生化条件。方法选择乙酸酐、三氟乙酸酐、3,5-二硝基苯甲酰氯3种衍生化试剂,以气相色谱作为检测方法,比较在不同的衍生条件下(加热方式、微波功率、时间等)的衍生效果。结果获得3种不同衍生化产物的气相色谱分析结果,得出苯丙胺类经乙酸酐乙酰化,于微波Ⅱ档衍生反应3min,衍生化反应完全满意的结果。结论在适当条件下选用乙酸酐对苯丙胺类进行完全的衍生化反应,适用于该类毒品的定量分析。  相似文献   

16.
Gamma-hydroxybutyric acid (GHB) can cause problems in interpretation of toxicological findings due to its endogenous nature, significant production in tissues after death and potential formation in stored samples. Our study was designed to determine the influence of storage conditions on GHB levels and its possible in vitro formation in blood and urine in cases where no exogenous use of GHB or its precursors was suspected. The samples were prepared by validated method based on liquid-liquid reextraction with adipic acid internal standard and MSTFA derivatization and assayed on a GC-MS operating in EI SIM mode. The first part of the study was performed with pooled blood and urine samples obtained from living and deceased subjects stored with and without NaF (1% w/v) at 4 and -20 degrees C over 8 months. In ante-mortem samples (both blood and urine) no significant GHB production was found. After 4 months of storage, the substantial GHB rise up to 100 mg/Lwas observed in post-mortem blood stored at 4 degrees C without NaF with subsequent gradual decrease in following months. The inhibition of GHB production was apparent during storage in NaF treated frozen blood samples. In post-mortem urine only slight temporary GHB levels were ascertained (up to 8 mg/L). The second part of our study was aimed to analyse 20 individual post-mortem blood samples stored at 4 degrees C for 16-27 days between autopsy and analysis without preservation followed by storage at 4 degrees C with NaF for 4 months. The temporary GHB production with maximum of 28 mg/Lwas detected in some samples.  相似文献   

17.
A simultaneous analytical method for etizolam and its main metabolites (alpha-hydroxyetizolam and 8-hydroxyetizolam) in whole blood was developed using solid-phase extraction, TMS derivatization and ion trap gas chromatography tandem mass spectrometry (GC-MS/MS). Separation of etizolam, TMS derivatives of alpha-hydroxyetizolam and 8-hydroxyetizolam and fludiazepam as internal standard was performed within about 17 min. The inter-day precision evaluated at the concentration of 50 ng/mL etizolam, alpha-hydroxyetizolam and 8-hydroxyetizolam was evaluated 8.6, 6.4 and 8.0% respectively. Linearity occurred over the range in 5-50 ng/mL. This method is satisfactory for clinical and forensic purposes. This method was applied to two unnatural death cases suspected to involve etizolam. Etizolam and its two metabolites were detected in these cases.  相似文献   

18.
苯丙胺类毒品三氟乙酰化气一质联用分析   总被引:2,自引:1,他引:1  
目的 考查了N甲基双三氟乙酰胺 (MBTFA)衍生化试剂对苯丙胺类毒品的衍生化效果与衍生化条件 ,建立该类毒品三氟乙酰化后的定性定量分析条件。方法 用三氟乙酰化气一质联用分析方法。结果 获得了衍生化产物经气质联用分析后的总离子流色谱图、质谱图及质谱断裂规律 ,以及各种定量参数。结论 经三氟乙酰化后分离效果得到改善 ,且衍生化完全 ,可用于该类毒品的定量分析。  相似文献   

19.
Vegetable oils have the ability to spontaneously heat under certain conditions, which may lead to spontaneous ignition. While the oils are not often encountered in forensic casework, they may be suspected in some fire cases. As these oils are not effectively analyzed using traditional fire debris analysis methods, a protocol must be established for extracting vegetable oils from fire debris. In this study, a protocol was developed for the extraction, derivatization, and analysis of vegetable oils from fire debris. Three derivatization methods were compared to establish an optimal derivatization procedure to convert the fatty acids found in vegetable oils to the fatty acid methyl esters (FAMEs) used in analysis. Three different gas chromatograph columns and programs were examined to determine which was best suited for the separation and analysis of FAMEs. The procedure was tested and refined using a variety of neat and burned vegetable oils, in addition to extractions from oils burned on commonly encountered fire debris materials. The findings of this research will serve as a starting point for further understanding and research of vegetable oils in fire debris.  相似文献   

20.
A method for the identification and quantification of hydroxyzine in human fluids by GC/NPD is presented. The method employs acepromazine as the internal standard and requires no derivatization. After a single alkaline extraction in n-heptane isoamylalcohol (98.5:1.5, v/v), analysis is achieved in 7 min. The lower limit of detectability was 0.8 ng/ml in plasma. Capillary gas chromatography mass spectrometry assay was developed for confirmation. Toxicological findings, after a fatality involving hydroxyzine are presented as an application of the procedure.  相似文献   