首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
This study assessed the performance of five different DNA extraction methods for the recovery of DNA from bone: ChargeSwitch® gDNA Plant Kit, DNA IQ™ System Kit, DNeasy® Blood & Tissue Kit, PrepFiler® BTA Forensic DNA Extraction Kit and phenol-chloroform-isoamyl alcohol. DNA was extracted from pig rib and femur bones that was fresh, had undergone surface decomposition for three months, and had undergone surface decomposition for one year. Extracted DNA was analyzed using real-time PCR and amplification of an in-house PCR multiplex that assessed the quality and quantity of DNA and for the presence of inhibitors. The phenol-chloroform-based method consistently yielded the highest amounts of DNA and DNA IQ the lowest; however, all methods produced relatively high yields of DNA from both pig rib and femur samples that could be amplified without any detected inhibition. The data demonstrate that with reasonable quality bone samples any of the tested methods can isolate DNA that can be successfully analyzed. The effective use of internal PCR controls is also demonstrated.  相似文献   

2.
In sexual assault cases DNA profiling of spermatozoa can be of critical importance. Most methods use differential extraction of the spermatozoa to separate it from the female component. Here we have compared two commercially available differential extraction methods, the QIAamp® DNA mini kit (Qiagen) and Differex™ with the DNA IQ® System (Promega). Simulated postcoital samples were prepared using buccal cells from a female donor and spermatozoa from three male donors. A dilution series ranging from neat semen to a 1:1500 dilution (semen:dH2O) was prepared and mixed with an equal volume of saliva from a female donor. Extraction efficiency was assessed using DNA concentration measured with NanoDrop 2000 and Quantifiler® Human DNA Quantification Kit and the profile count of full, partial and mixed DNA profiles generated using SGM Plus and PowerPlex® ESI 17. Statistical analysis was carried out using Randomisation in R, which is a robust model making no assumption of the distribution of data. Based on the amount of DNA extracted and the types of profiles no significant difference in the performance of the two extraction kits was seen. However, the processing time taken with the Differex™ System was about half than that of the QIAamp® DNA mini kit and involved fewer liquid transfers.  相似文献   

3.
Manual Chelex®-100 and organic extractions (phenol/chloroform) are used as routine methods at the Swedish National Laboratory of Forensic Science, SKL. The aim of this study was to find an automated DNA purification system to replace the organic method. The following methods were evaluated and compared to each other and to the organic method used routinely; BioRobot® EZ1 with EZ1 DNA Investigator Kit and Card (Qiagen), iPrep™ Purification Instrument with iPrep™ ChargeSwitch® Forensic Kit and Card (Invitrogen), Magnatrix™ 1200 Workstation with the Magnatrix™ gDNA Blood Kit Forensic and two different protocols; Forensic protocol A and B (Magnetic Biosolutions). Blood on fats, cotton swabs, moist snuff, paper towels and leather, post-mortem blood and muscle tissue were extracted with the different methods. DNA concentration and quality of the electropherograms were examined. Individual comparisons between the four extraction methods showed that iPrep™ and Magnatrix™ 1200 gave significantly lower mean quantities compared to BioRobot® EZ1 and the organic extraction method (p < 0.05). There were no significant differences between the latter two. BioRobot® EZ1 generated the best results and is in the process of being validated for routine analysis at SKL.  相似文献   

4.
Analysis of STR profiles obtained from touch DNA has been very useful to the elucidation of crimes. Extraction method may be determinant for the recovery of genetic material collected from different surfaces. Vehicle theft is one of the most common crimes in São Paulo city, Brazil, but collection of biological traces in car steering wheels is not considered, because of the belief that profiles generated won’t be able to identify the thief, only the owner. This study aimed to analyze the efficacy of extraction methods for obtaining DNA profiles in samples collected from steering wheels. Eight criminal acts were simulated with 2 different individuals each (mixture of victim and thief), in duplicate, in order to compare two extraction methods: DNA IQ™ and Casework Direct Kit (both Promega Corporation). Genetic material was collected by double swab method and quantified by Quantifiler™Trio (ThermoFisher Scientific). Amplification was conducted with PowerPlex® Fusion System (Promega). It was possible to obtain STR profiles for all experiments. The mixtures were compared with reference profiles to evaluated how many alleles of each donor were observed. Samples extracted with Casework Direct Kit obtained STR profiles with higher averages of alleles for primary and secondary donors (88.7% and 59.9%, respectively) than those extracted with DNA IQ™ (60.4% and 38.1%, respectively). This could be explained by the differences established in the protocols of both methods, since DNA IQ™ is based on successive washes and can result in loss of DNA, whereas Casework Direct Kit minimizes this problem. We concluded that Casework Direct Kit was more efficient for processing touch DNA samples than DNA IQ™.  相似文献   

5.
In forensic science, fingerprints are a common source of evidentiary information. However, latent examination is not always successful and trace human DNA cannot always be obtained. Thus, examining the fingerprint microbiome may offer a suitable alternative to more traditional methods of forensic identification. The Zymo Research ZR Bacterial/Fungal DNA MicroPrep™ Kit, Qiagen QIAmp® DNA Mini Kit, Promega Wizard® Genomic DNA Purification Kit, and the MPBio FastDNA® Spin Kit were compared for their ability to yield a sufficient amount of bacterial DNA for next-generation sequencing in order to obtain a microbiome profile. Prints were deposited onto slides, allowed to sit for up to 1 month, and total DNA isolated and quantified using each kit. The kit from Zymo Research yielded the most concentrated DNA sample (0.0084 ng/µL) in the least amount of time as compared to other kits examined. Although this amount of DNA was far below the recommended DNA concentration threshold recommended for next-generation sequencing, a microbiome profile was successfully obtained. As interest in using the microbiome of an individual as a forensic tool continues to increase, there is the possibility that the microbiome of a fingerprint could complement traditional human DNA profiling in the future. This study provides evidence that trace amounts of bacterial DNA from fingerprints is quantifiable and sufficient for microbiome analysis.  相似文献   

6.
Calcified tissues, such as bone and tooth, and some other sample types, such as those containing adhesive, present a challenge to standard extraction protocols. We have developed a lysis reagent, BTA™ lysis buffer, which is designed for use with PrepFiler™ Kit reagents. The BTA™ lysis buffer disrupts calcified tissue matrices and achieves effective extraction of DNA from pulverized bone and tooth samples. In addition, the BTA™ lysis buffer mildly but efficiently extracts DNA from challenging substrates like tape, chewing gum, and cigarette butts and, as with bone and tooth, DNA from these lysates is purified using established PrepFiler™ reagent extraction protocols.We successfully extracted DNA from powdered human bone samples, chewed gum and smoked cigarettes using BTA™ lysis buffer. Extraction yields for bone, gum and cigarette samples tested were consistent and reproducible. This extraction method efficiently removed potential PCR inhibitors from all samples tested, and CT values for the internal PCR control of Quantifiler® Human DNA Quantification Kit were consistent and within the normal range. The DNA extracted from these samples also provided conclusive profiles that were free of PCR artifacts when amplified using the AmpF?STR® Identifiler® PCR Amplification Kit. The protocol is easily adapted for automation.  相似文献   

7.
Within the initial step of the forensic DNA analysis process, the DNA extraction efficiency and especially the removal of potential PCR inhibitors is crucial for subsequent steps, e.g. quantification by real-time PCR and amplification of short tandem repeats (STRs). The protocol of the PrepFiler™ Forensic DNA Extraction Kit was optimized for the application on a Tecan liquid handling workstation Freedom EVO® 150. This modified application of the PrepFiler™ technology was compared with respect to DNA yield, sensitivity and the ability to remove potential PCR inhibitors to an established routine method working on the same liquid handling workstation based on ChargeSwitch® Technology (CST) from Invitrogen.  相似文献   

8.
Formalin-fixed and paraffin-embedded tissue (FF-PET) is an invaluable resource for retrospective molecular genetic studies, but the extraction of high-quality genomic DNA from FF-PET is still a problematic issue. Despite the range of DNA extraction methods currently in use, the association of phenol–chloroform extraction and silica-based purification protocols, reported in ancient DNA studies on archaeological bones, has, to our knowledge, not been used for DNA extraction from FF-PET yet. The present study compared the efficiency of three DNA extraction and purification protocols from two different FF-PET substrates, heart and liver, by using quantitative PCR and multiplex amplification.We showed that the method, using phenol–chloroform and the QIAamp DNA mini® Kit (Qiagen), was the most effective DNA extraction and purification method and that the DNA quantity extracted from liver is statistically more important than that extracted from heart. Autosomal STR typing by multiplex amplifications gave partial allelic profiles with only small size products (less than 300 bases) amplified, suggesting that DNA extracted from FF-PET was degraded.In conclusion, the protocol presented here, previously described in studies on ancient bones, should find application in different molecular studies involving FF-PET material.  相似文献   

9.
Psilocybe cubensis, or “magic mushroom,” is the most common species of fungus with psychedelic characteristics. Two primer sets were designed to target Psilocybe DNA using web‐based software and NBCI gene sequences. DNA was extracted from eighteen samples, including twelve mushroom species, using the Qiagen DNeasy® Plant Mini Kit. The DNA was amplified by the polymerase chain reaction (PCR) using the primers and a master mix containing either a SYBR® Green I, Radiant? Green, or LCGreen Plus® intercalating dye; amplicon size was determined using agarose gel electrophoresis. The PCR assays were tested for amplifiability, specificity, reproducibility, robustness, sensitivity, and multiplexing with primers that target marijuana. The observed high resolution melt (HRM) temperatures for primer sets 1 and 7 were 78.85 ± 0.31°C and 73.22 ± 0.61°C, respectively, using SYBR® Green I dye and 81.67 ± 0.06°C and 76.04 ± 0.11°C, respectively, using Radiant? Green dye.  相似文献   

10.
East Timor is a country located in Southeast Asia. In this study, we determined allele frequencies and forensic parameters for 24 STR autosomal loci included in the PowerPlex® Fusion System. Autosomal STR data was collected from saliva samples of 100 individuals from East Timor. The amplification of the 24 autosomal STRs was performed using PowerPlex® Fusion System (Promega Corporation) and the amplified products were analysed on 3500 Genetic Analyser using GeneMapper® ID-X 1.2 Software (Applied Biosystems). All the analysed loci meet Hardy–Weinberg equilibrium after Bonferroni correction. In our samples, we found “off-ladder” alleles (D2S441, Penta E and FGA locus) confirmed by reamplification, amplification with others kits and sequenced when justified.  相似文献   

11.
STR profiling using hard tissues obtained from a severely decomposed body is sometimes a laborious work. There is now on a market a new DNA extraction kit, PrepFiler™ Forensic DNA Extraction Kit (AppliedBiosystems), and we tested it for missing persons. Postmortem intervals ranged from weeks to several years. Fifteen bone fragments and eleven nails were used in this report. Genomic DNA was quantified by QuantiFiler® DUO Quantification Kit (AppliedBiosystems), and STRs were analyzed using AmpFlSTR® Identifiler® PCR Amplification Kit (AppliedBiosystems). The profiling of 16 STR loci was successful in all nail samples. However, STR profiling was successful in only 6 of 15 bone materials. Nine cases failed to analyze STR polymorphisms using another DNA extraction kit, the QIAamp DNA Mini Kit (QIAGEN). For bone samples, it seems that STR profiling depends on the quality of samples.  相似文献   

12.
Abstract: The PrepFiler? Forensic DNA Extraction Kit enables isolation of genomic DNA from a variety of biological samples. The kit facilitates reversible binding of DNA with magnetic particles resulting in high DNA recovery from samples with very low and high quantities of biological materials: 0.1 and 40 μL of human blood (donor 2) provided 14 and 2883 ng of DNA, respectively. Following the revised SWGDAM guidelines, performance of the developed method was investigated using different sample types including saliva on swabs, semen stains on cotton fabric, samples exposed to environment, samples with polymerase chain reaction (PCR) inhibitors, blood stains (on denim, cotton cloth, and FTA® paper), and touch evidence‐type samples. DNA yields for all samples tested were equal or better than those obtained by both phenol–chloroform extraction and commercial kits tested. DNA obtained from these samples was free of detectable PCR inhibitors. Short tandem repeat profiles were complete, conclusive, and devoid of PCR artifacts.  相似文献   

13.
Abstract: Obtaining complete short tandem repeat (STR) profiles from fingerprints containing minimal amounts of DNA, using standard extraction techniques, can be difficult. The aim of this study was to evaluate a new kit, Fingerprint DNA Finder (FDF Kit), recently launched for the extraction of DNA and STR profiling from fingerprints placed on a special device known as Self‐Adhesive Security Seal Sticker® and other latent fingerprints on forensic evidentiary material like metallic guns. The DNA extraction system is based on a reversal of the silica principle, and all the potential inhibiting substances are retained on the surface of a special adsorbent, while nucleic acids are not bound and remain in solution dramatically improving DNA recovery. DNA yield was quite variable among the samples tested, rendering in most of the cases (>90%) complete STR profiles, free of PCR inhibitors, and devoid of artifacts. Even samples with DNA amount below 100 pg could be successfully analyzed.  相似文献   

14.
运用酚-氯仿法结合磁珠法提取蝇蛆体内人类DNA   总被引:1,自引:0,他引:1  
目的建立运用酚-氯仿法结合磁珠法从蝇蛆嗉囊内提取人类DNA的方法,从而提高STR分型检验的灵敏度。方法采用酚-氯仿法对蝇蛆嗉囊内容物中的人类DNA进行提取,提取产物经磁珠法纯化浓缩后用QuantifilerTM人类DNA定量试剂盒在7500型实时荧光定量PCR仪上进行PCR定量,再用AmpF■STR IndentifilerTM试剂盒在3130XL-Avant遗传分析仪上对这些DNA样本进行STR分型。结果本研究建立的方法可增加模板DNA浓度约为单独使用酚-氯仿法的2倍。用此方法提取到的DNA浓度[(0.218±0.041)ng/μL]可获得全部16个STR分型结果。结论酚-氯仿法结合磁珠法可以有效地提高提取到的人类DNA样本STR分型检验的灵敏度,对于从事法医昆虫学方面研究的工作者有较好的实用价值。  相似文献   

15.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

16.
The analysis of degraded DNA is one of the biggest challenges in forensic casework. SNPs, which can be amplified using small amplicons, have previously been successfully applied to the profiling of forensic evidence that could not be analyzed using conventional STRs. Here we selected the 52 SNPforID SNP markers, with amplicons that ranged in size from 59 bp to 115 bp, and used them to profile a range of casework samples from Malaysia. DNA degradation is a common problem in Malaysia due to the high temperatures and humidity. To carry out the study we modified the 52 SNPforID markers into four 13-plex SNaPshot assays to enable easier interpretation of profiles on the ABI PRISM® 310 and 3500.Fifty-one crime samples comprising bloodstains on cloth, swabs, and a mat and 2 swabs of trace DNA from 10 crime scenes in Malaysia were profiled after DNA extraction using a phenol–chloroform method. The samples were also subjected to STR analysis using the Powerplex® 16 system (Promega), which resulted in only 17 full profiles and 9 partial profiles; using SNPs, 36 full profiles and 5 partial profiles could be generated.  相似文献   

17.
We have implemented and validated automated methods for DNA extraction and PCR setup developed for a Tecan Freedom EVO® liquid handler mounted with a Te-MagS™ magnetic separation device. The DNA was extracted using the Qiagen MagAttract® DNA Mini M48 kit. The DNA was amplified using AmpF?STR® Identifiler®, Y-filer® (Applied Biosystems), GenePrint® FFFL and PowerPlex® Y (Promega). The methods were validated for fresh whole blood and blood from deceased according to EN/ISO 17025.  相似文献   

18.
Abstract: DNA amplification is a fundamental yet costly process used in DNA analysis. This study evaluated half‐reaction amplification (12.5, 12, and 13 uL) using the Promega Powerplex® 16 Kit with the hope of reducing sample analysis costs by half. A sensitivity study was completed, along with the testing of various blood stain samples including those with low (<0.40 ng) and high DNA concentrations (>3.0 ng), peak height imbalances, and allelic drop‐out. Also, 467 samples submitted to the MUFSC laboratory for testing were analyzed. Results indicate that half‐reaction amplification produced higher quality profiles than full‐reactions. Average peak heights increased by 85%, peak height imbalances improved, and drop‐out was eliminated in 75.8% of samples. Only eight of 467 case samples required re‐amplification, a success rate of 94% was observed, and the repeat rate decreased significantly. Finally, a DNA input of 0.25–1.0 ng is ideal for half‐reaction amplification.  相似文献   

19.
Traditionally, DNA extracts from biological evidence items have been concentrated and rinsed using microdialysis filtration units, including the Centricon® and Microcon® centrifugal filter devices. As an alternative to microdialysis filtration, we present an optimized method for using NucleoSpin® XS silica columns to concentrate and clean-up aqueous extracts from the organic extraction of DNA from biological samples. The method can be used with standard organic extraction and dithiothreitol (DTT)-based differential extraction methods with no modifications to these methods prior to the concentration and clean-up step. Extracts from laboratory-prepared bloodstains, saliva and semen stains have been successfully amplified with both qPCR and STR assays. Finally, the total time to process a set of samples with the NucleoSpin® XS column is approximately 30 min vs. approximately 1.5 h with the Centricon® YM-100 filter device.  相似文献   

20.
In human identification, the victim's toothbrush is an invaluable personal item as the deposited cellular material contains DNA from which a reference profile can be produced. The profile obtained then allows direct comparison to be made with the profile from the unidentified body. This study was undertaken to determine the minimum number of bristle bundles that would generate a complete DNA profile. The minimum period of usage for a toothbrush to retain enough cells for genotyping was also investigated. We also tested two commonly used DNA extraction methods: QIAamp® DNA Mini Kit and Chelex® 100 to explore the efficiency of these protocols in recovering DNA from toothbrushes. In this experiment, volunteers brushed their teeth for 1, 7, 14, or 30 days. DNA was extracted from 5 and 10 bundles of bristles cut from the collected toothbrushes. The amount of DNA recovered was quantified by quantitative real-time PCR, and DNA genotyping was performed for each sample. Data revealed that QIAamp® DNA Mini Kit performed better at yielding DNA in terms of purity, quantity, and quality than Chelex® 100. It was also found that, with a suitable method of recovery, DNA samples from five bundles of bristles from all of the toothbrushes generated complete profiles. Based on the experimental results, a general guideline concerning the appropriate extraction method and the quantity of the starting material for the analysis of DNA from toothbrushes could be suggested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号