首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
We previously reported that detection of Streptococcus salivarius is feasible for proving the presence of saliva in a forensic sample. Here, a simple and rapid method for the detection of S. salivarius in forensic samples was developed that uses loop-mediated isothermal amplification (LAMP). The LAMP primer set was designed using S. salivarius-specific sequences of glucosyltransferase K. To simplify the procedure, the sample was prepared by boiling and mutanolysin treatment only, and the entire analytical process was completed within 2.5 h. The cut-off value was set at 0.1 absorbance units, measured at 660 nm, upon termination of the reaction. S. salivarius was identified in all saliva samples, but was not detected in other body fluids or on the skin surface. Using this method, S. salivarius was successfully detected in various mock forensic samples. We therefore suggest that this approach is useful for the identification of saliva in forensic practice.  相似文献   

2.
Saliva on skin is important in forensic trace evidence. If areas where saliva is present can be outlined, this may lead to DNA analysis and identification. This study describes a rapid and non-destructive method to detect dried saliva on the surface of the skin by fluorescence spectroscopy. Eighty-two volunteers deposited samples of their own saliva on the skin of their ventral forearm. A control sample of water was deposited at three different sites on the contralateral arm. Saliva and water control were then allowed to air-dry. Swab samples were taken from dried saliva and control sites and were dissolved in 0.1M KCl solution. Emission spectra were obtained from the solution and were characterized by a principal maximum at 345-355nm with excitation at 282nm. The fluorescence emission intensity was greater than background readings obtained from the control swab site in 80 of 82 volunteers (approximately 97.6%). The fluorescence profile of saliva samples were similar to those obtained from aqueous samples of pure amylase and tryptophan, an endogenous fluorophore in alpha-amylase. The presence of an emission peak at 345-355nm with excitation at 282nm could provide a strong presumptive indication of saliva deposition.  相似文献   

3.
Abstract:  Current methods for forensic identification of saliva generally assay for the enzymatic activity of α-amylase, an enzyme long associated with human saliva. Here, we describe the R apid S tain ID entification (RSID™-Saliva), a lateral flow immunochromatographic strip test that uses two antisalivary amylase monoclonal antibodies to detect the presence of salivary amylase, rather than the activity of the enzyme. We demonstrate that RSID™-Saliva is accurate, reproducible, and highly sensitive for human saliva; RSID™-Saliva detects less than 1 μL of saliva. The sensitivity of RSIDTM-Saliva allows investigators to sample a fraction of a questioned stain while retaining the majority for DNA-STR analysis. We demonstrate that RSID™-Saliva identifies saliva from a variety of materials (e.g., cans, bottles, envelopes, and cigarette-butts) and it does not cross-react with blood, semen, urine, or vaginal fluid. RSID™-Saliva is a useful forensic test for determining which evidentiary items contain saliva and thus may yield a DNA profile.  相似文献   

4.
PSA is currently being used to detect and monitor quantitatively the development of prostate cancer by serum levels of PSA and has also been found to be present in high concentrations in semen. Elegantly simple, sensitive, and reproducible methods have been developed for analysis of the presence of PSA, including the Tandem-E PSA Immunoenzymetric Assay. The most common procedures for the forensic identification of semen have focused on the microscopic detection of sperm, acid phosphatase activity, and immunoelectrophoretic methods for the detection of PSA. Although these methods have been used for many years, there are problems associated with each method. The Tandem-E PSA Immunoenzymetric Assay detected PSA in 100% of the forensic casework fabric samples, 80% of the forensic casework vaginal swabs and 100% of the vasectomized individuals tested. The cut-off value was determined to be 1.77 ng/mL. These results indicate that this method can be used to identify the presence of semen in forensically significant specimens.  相似文献   

5.
The identification of species in casework samples is of fundamental importance for forensic investigations. Laboratories are increasingly compelled to provide accurate and fast identifications in trace materials left on crime scenes, wildlife poaching, illegal trade of protected species, fraudulent food products cases, etc. However, the field of nonhuman forensic genetics is still working on the standardization of typing methods and practices. Here we describe the successful implementation of the Species Identification by Insertions/Deletions (SPInDel) method in routine casework analyses in 11 laboratories worldwide. The SPInDel was developed to detect human DNA, at the same time that identifies common animal species. The fragment size analysis of six mtDNA regions allows identification in suboptimal DNA samples, including mixtures, with no need for sequencing. The samples were collected from 2013 to 2018 and included hair, blood, meat, saliva, faeces, bones, etc. The SPInDel kit successfully identified >95% of the samples, being dog, human and pig the most frequently detected species. The six SPInDel loci were successfully amplified in mixtures and degraded samples (river water, sand, stains in clothes, etc.). Interestingly, several species that were not originally targeted by SPInDel primers were also identified (e.g., red fox, brown bear, fallow deer and red deer). In conclusion, the SPInDel kit was successfully used in crime scene investigations (often involving human DNA detection) and in cases of poaching, environmental contamination and food fraud. It is now becoming a useful tool for the routine analysis of nonhuman DNA samples within the high quality standards of forensic genetics.  相似文献   

6.
Distinguishing between bloodstains caused by a spatter pattern or by expirated blood may be crucial to a forensic investigation. Expirated blood is likely to be contaminated with saliva but current techniques have limited sensitivity, especially with small bloodstains. We report that a PCR assay, designed to detect salivary bacteria, can amplify streptococcal DNA from saliva stains applied to fabrics for at least 62 days after seeding. Bacterial DNA was detected when 0.01 µl of saliva was present in the stain and the amplification was not affected by contamination with blood. These findings indicate that PCR amplification of salivary microbial DNA may have application in the identification of expirated bloodstains in forensic case-work.  相似文献   

7.
目的采用磁珠直接吸附法对人体尿液、唾液、血液3种体态生物检材中的游离DNA进行提取检验,为法医物证中游离DNA的研究及检验工作提供参考。方法对3种生物检材采取离心吸取上清液的方法分离游离DNA,然后采用磁珠直接吸附法进行提取纯化,Identifiler-Plus试剂盒进行复合扩增后常规STR检测。结果在3种检材中均检出了游离DNA,其中血液中游离DNA检出率为100%,唾液为90%,尿液为70%。结论人体体态生物检材中存在游离DNA,同时磁珠直接吸附法可高效、快捷的提取生物检材中的游离DNA。  相似文献   

8.
Semenogelin (Sg), a protein originating in the seminal vesicles and a substrate for prostate specific antigen (PSA or p30), is a useful marker for the identification of semen. And detection of Sg has been available commercially in a membrane test recently. PSA is commonly used to detect semen in forensic significant samples taken from sexual assault cases. The strip PSA test has been available commercially from various manufacturers for many years. In this study, we evaluated two immunochromatographic membrane tests, one for Sg and the other for PSA by analyzing human semen, other human bodily fluids/materials including urine, blood, saliva, sweat, breast milk, vaginal secretion and fecal materials, semen from various animals and forensic casework samples. The data demonstrate that both Sg and PSA strip tests provide rapid and sensitive method for identification of seminal plasma. These results show that the immunochromatographic method for Sg detection is useful for the identification of seminal plasma in forensic samples, an alternative to the method for PSA detection.  相似文献   

9.
The stability of salivary α‐amylase is a critical factor in both catalytic and immunological method‐based forensic saliva identification. This study aimed to assess the sensitivity of catalytic and immunological tests on degraded saliva samples. Degraded saliva stains were prepared by microbial decomposition using humid soil. Salivary α‐amylase activity was catalytically detected both qualitatively and quantitatively using the Phadebas® amylase test. As immunological methods, we conducted qualitative and quantitative tests using the RSID?‐saliva test and ELISA, respectively. Salivary α‐amylase activity of degraded samples (incubated at 37°C for 12 h) was significantly lower than that of controls in the quantitative tests. All the degraded samples obtained by the humid soil produced negative results in the Phadebas® tests, but showed positive results in the RSID?‐saliva test and ELISA. These results suggest that immunological tests are effective for testing degraded saliva samples that have lost their enzymatic activity.  相似文献   

10.
We have used the 16S–23S rRNA intergenic spacer region for identifying vaginal specific bacteria. Lactobacillus crispatus and Lactobacillus gasseri were detected in vaginal secretions but not in semen, blood or saliva. Our data indicated that both L. crispatus and L. gasseri were detected in vaginal secretions from women with different levels of expression of hormonal genes including pregnant, pre- and post-menopausal women, and a woman who has had a hysterectomy. Therefore, we have demonstrated that these Lactobacilli are promising new markers for the forensic identification of vaginal secretions. We have incorporated the Lactobacilli markers into a mRNA multiplex system to produce an 11-plex assay that can identify circulatory blood, menstrual blood, saliva, semen (in the presence and absence of spermatozoa) and vaginal secretions.  相似文献   

11.
12.
Evaluation of microRNA (miRNA) expression as a potential method for forensic body fluid identification has been the subject of investigation over the past several years. Because of their size and encapsulation within proteins and lipids, miRNAs are inherently less susceptible to degradation than other RNAs. In this work, blood, urine, semen, and saliva were exposed to environmental and chemical conditions mimicking sample compromise at the crime scene. For many treated samples, including 100% of blood samples, miRNAs remained detectable, comparable to the untreated control. Sample degradation varied by body fluid and treatment, with blood remarkably resistant, while semen and saliva are more susceptible to environmental insult. Body fluid identification using relative miRNA expression of blood and semen of the exposed samples was 100% and 94%, respectively. Given the overall robust results herein, the case is strengthened for the use of miRNAs as a molecular method for body fluid identification.  相似文献   

13.
Saliva stains present a unique challenge in the forensic setting, often challenging the analyst to weigh the value of presumptive indication of the fluid versus the potential for DNA analysis to yield identification information. There are many situations in which determining the presence of a body fluid is probative and further corroborates DNA evidence. That said, even a minute portion of sample consumed by a screening test could mean the difference between a full, partial, or null profile obtained through DNA analysis. The basis of presumptive testing or screening of saliva has historically been based on the presence of amylase, a component found in relatively high concentrations in human saliva versus other body fluids and substances. Though the current available methods for the screening of saliva in a forensic application have grown in number, the popularity of these methods seemingly has not. This study attempts to identify a specific and sensitive saliva screening test by comparing three modern techniques--the recently released SALIgAE, Phadebas, and starch-iodine mini-centrifuge test--on the basis of sensitivity, specificity, mixtures, and simulated casework samples while also considering sample consumption. The Phadebas method for presumptive saliva testing detected dilutions of neat saliva down to 1:200 versus considerably less sensitive results with SALIgAE and the starch-iodine mini-centrifuge test. Utilizing a screening test with a high degree of sensitivity, such as Phadebas, allows an analyst to gain a maximum amount of information in the form of body fluid indication and DNA results because of the consumption of a small portion of sample.  相似文献   

14.
唾液及含唾液检材的DNA分析   总被引:1,自引:0,他引:1  
提取160份唾液及含唾液的检材中的DNA,并根据DNA的质和量进行了DNA指纹图检验或应用聚合酶链反应(PCR)进行了DNA分型。结果表明,唾液和含唾液检材是很好的DNA来源.对其进行DNA分析是可行的。  相似文献   

15.
The ability to detect semen in sexual offence cases is a crucial first step to locating stains which may be suitable for DNA profiling. Since the development of the acid phosphatase test in the late1950s by Stuart S. Kind, the process undertaken to perform the test has gone largely unchanged. The method currently accepted by operational forensic science laboratories allows 2 min for a reaction to be obtained, and until relatively recently, this has not been challenged. In this research, samples of semen were obtained from three donors and a range of dilutions for each sample were prepared. Each dilution was subjected to acid phosphatase testing using both direct testing and the ‘press test’ method. The results showed that semen could be detected in excess of 15 min in dilutions up to 1 in 400 using the press test method and in dilutions up to 1 in 1000 using the direct method. Of further significance was the observation that using the press test method, the two minute cut-off was insufficient to detect the majority of stains and in some cases, semen stains as strong as 1 in 20 dilutions. This research provides compelling evidence for protocols currently utilised in forensic practice to be reviewed in order that forensic scientists do not overlook potential evidential material that may prove suitable for body fluid identification such as DNA STR profiling.  相似文献   

16.
Molecular‐based approaches for biological source identification are of great interest in the forensic community because of a lack of sensitivity and specificity in current methods. MicroRNAs (miRNAs) have been considered due to their robust nature and tissue specificity; however, analysis requires a separate RNA extraction, requiring an additional step in the forensic analysis workflow. The purpose of this study was to evaluate miRNA detection in blood, semen, and saliva using DNA extraction methods commonly utilized for forensic casework. RT‐qPCR analysis revealed that the tested miRNAs were consistently detectable across most tested DNA extraction methods, but detection was significantly reduced compared to RNA extracts in some biological fluids. DNase treatment was not necessary to achieve miRNA‐specific results. A previously developed miRNA panel for forensic body fluid identification was evaluated using DNA extracts, and largely demonstrated concordance with results from samples deriving from RNA extracts of semen, blood, and saliva.  相似文献   

17.
Abstract: In this study, Tamm‐Horsfall protein (THP), a major component of urinary protein, and uroplakin III (UPIII), a transmembrane protein widely regarded as a urothelium‐specific marker, were evaluated for forensic identification of urine by ELISA and/or immunohistochemistry. THP was detected in urine, but not in plasma, saliva, semen, vaginal fluid, or sweat by the simple ELISA method developed in this study. In addition, most aged urine stains showed positive results. The urine specificity of THP was confirmed by gene expression analysis. Therefore, as reported previously, ELISA detection of THP can be used as a presumptive test for urine identification. UPIII was specific for immunohistochemical staining of cells in centrifuged precipitate of urine. However, ELISA and RT‐PCR for UPIII were not specific for urine. UPIII may be applicable for forensic urine identification by immunohistochemistry.  相似文献   

18.
Increasing numbers of unidentified cadavers are a major problem. We have developed a new method for providing identification information that can determine the geographical origin or place of long‐term residence of unidentified cadavers based on genotypic polymorphisms of hepatitis B virus (HBV) known to correlate with their geographical distribution. PCR of serum samples detected HBV DNA from 4 (3.9%) of 102 randomly selected Japanese forensic cadavers. Multiplex PCR did not detect multiple HBV genotypes from any single cadaver, confirming the absence of coinfection. Phylogenetic tree analysis based on a 485‐bp mutant region of the HBV S gene successfully classified the HBV genotypes into A to J. Among 10 HBV‐infected cadavers, 8 had genotype Ce/C2, a genotype prevalent in East Asia, and 2 had genotype Bj/B1, a Japanese‐specific genotype. HBV genotypic polymorphisms correlate with the geographical distribution of the virus and thus provide important information for identifying unidentified cadavers infected with HBV.  相似文献   

19.
《Science & justice》2023,63(4):493-499
Forensic scientists are often asked to assist the court by evaluating the significance of finding body fluids on the hands of an individual; however, there is an absence of published data regarding the background levels of body fluids on hands. Whilst the scientist can use casework experience to inform the courts on the significance of the results, it would be advantageous to have data which could assist with this interpretation. This study was designed to ascertain the background levels of blood, semen, saliva, hairs/fibres and staining/debris on hands in the general population by sampling from delegates attending a scientific conference.The findings suggest that approximately one third of the population would be expected to have hairs or fibres on their hands and that females are more likely to have visible staining on their hands than males. Presumptive tests for blood and semen yielded negative results in all samples; however, almost 2 % of the samples were found to contain a very low number of sperm heads. In contrast, the majority of samples tested positive for the presence of saliva using the presumptive Phadebas® amylase test. The data supports the caution applied by forensic practitioners when evaluating the presence of saliva detected using the presumptive Phadebas® amylase test based on the lack of specificity and indicates that the RSID™-Saliva test would be more suitable to use.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号