首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
法律   3篇
  2002年   2篇
  2001年   1篇
排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
2.
Quality assurance samples submitted from the NCSBI as part of a contract with TBTG to outsource DNA Database samples showed unexpected discrepancies for the locus D16S539 when all other loci yielded identical results. Discrepancies observed included allele drop out and an imbalance in sister alleles with samples returned from TBTG. This led to a comprehensive review of the technical procedures used between the two laboratories to determine the cause of the discrepancies noted for the locus D16S539, since both laboratories were using the PowerPlex 1.1 typing kit from the Promega Corporation. The NCSBI and the TBTG utilize different extraction methods (organic extraction vs. FTA) and amplification conditions (AmpliTaq vs AmpliTaq Gold), respectively, so the exact cause of discrepancy observed was not immediately apparent. Experiments at the NCSBI associated the observed allele drop out and the imbalance of the sister alleles with the use of AmpliTaq Gold and a hot start procedure. Sequencing data revealed that a point mutation resides on the D16S539 primer-binding site that reaches polymorphic levels in African-American populations. This led to the development of a degenerate primer by the Promega Corporation to detect "missing" alleles when AmpliTaq Gold is used. The degenerate primer was then thoroughly tested to show its efficacy in detecting the "true" D16S539 profile when used.  相似文献   
3.
In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号