首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 421 毫秒
1.
Chelex-100法提取脱落细胞检材DNA的实时定量研究   总被引:1,自引:0,他引:1  
杨电  刘超  徐曲毅  胡慧英 《刑事技术》2009,(5):30-31,34
目的研究脱落细胞检材DNA检验的简便有效的提取方法。方法对76份包括帽子、眼镜、牙刷、剃须刀、梳子、口香糖、羊水在内的7种脱落细胞检材采用Chelex-100法提取DNA,在ABI7500型荧光定量PCR仪上进行定量,同时用Identifiler复合扩增系统扩增,在ABI3130遗传分析仪上进行STR分型。结果从帽子(头套)中获得的脱落细胞DNA平均含量为8.31ng,眼镜擦拭物上获得的脱落细胞DNA平均含量为6.20ng,牙刷上获得的脱落细胞DNA平均含量为49.40ng,剃须刀擦拭物上获得的脱落细胞DNA平均含量为6.92ng、梳子擦拭物上获得的的脱落细胞DNA平均含量为10.68ng,口香糖的脱落细胞DNA平均含量为16.30ng,羊水的脱落细胞DNA平均含量为320ng。以上76份检材性别及10个以上STR位点分型成功率为75.8%。结论从帽子、眼镜、牙刷、剃须刀、梳子、口香糖、羊水等检材提取的脱落细胞可用Chelex-100法提取DNA作STR分型。  相似文献   

2.
Chelex-100提取生物检材DNA实时PCR定量研究   总被引:3,自引:1,他引:2  
目的研究Chelex-100法提取的生物检材DNA用量与复合STR分型成功率的关系。方法113份各种生物检材采用Chelex-100法提取DNA,应用Quantifiler人类DNA定量试剂盒在ABI 7500荧光定量PCR仪上进行实时PCR定量,同时用Identifiler复合扩增系统在ABI 3100遗传分析仪上对这些DNA样品进行STR分型。结果各种生物检材提取的DNA浓度分别为:37份滤纸、纱布血痕0.042~5.28ng/μl,16份口腔拭子1.15—4.21ng/μl,18份烟头0.016~1.46ng/μl,10份肋软骨0.531—14.40ng/μl,8份肌肉5.75—24.80ng/μl,7份指甲0.788—11.50ng/μl,17份精斑0.79~99.50ng/μl。在建立的8μl扩增体系中,根据上述结果,调整用于复合STR扩增的DNA模板量在0.5—3ng之间,大部分样品可获得完全的STR分型。结论Chelex-100法提取的检材DNA模板用量在0.5—3ng之间可得到有效STR扩增,浓度为0.5ng/μl以上的DNA样品,用小体积模板(1μl)比大体积(3μl)模板扩增效果好。  相似文献   

3.
一种收集衣服上脱落细胞的新方法   总被引:3,自引:2,他引:1  
目的建立一种生物脱落细胞的微量提取新方法。方法利用一套自制的“生物细胞提取仪”无损提取衣物等载体上的人体脱落细胞,采用Chelex-100法提取DNA,用不同的试剂盒进行STR复合扩增检验。结果10例检材都得到16个基因座成功分型。结论用该方法提取微量细胞DNA,可获得满意的DNA分型。  相似文献   

4.
目的比较Chelex-100法和硅珠法两种DNA提取法,在签字笔上附着微量脱落上皮细胞分型中的应用效果。方法 17名志愿者每人使用14支签字笔,每支笔每天使用20min,为期1个月,平均分为两组,分别保存1、3、5、7、14、21和28d,同时运用Chelex-100法和硅珠法两种方法提取签字笔上遗留微量脱落细胞中的DNA,用Identifiler复合扩增系统在AB I 3100遗传分析仪上对这些DNA样品进行STR分型,同时采集上述17名志愿者口腔拭子作为对照。结果以基因座检出个数为指标,使用后签字笔保存1、3、5、7、14、21和28d后,采用Chelex-100法和硅珠法两种方法提取DNA并进行分型检出的基因座个数相比差异均有统计学意义(P0.01);口腔拭子保存1、3、5、7、14、21和28d后,采用Chelex-100法和硅珠法两种方法提取DNA并进行分型检出的基因座个数相比差异均无统计学意义(P0.05)。结论对于微量检材,应用硅珠法提取的DNA分型效果明显优于Chelex-100法,具有较高的应用价值,而在检材量比较多时区别不明显。  相似文献   

5.
封宇  严密  刘云  陈骏 《法医学杂志》2008,24(6):435-436
目的 探索牙刷刷毛黏附口腔黏膜脱落细胞DNA提取有效方法.方法 采用牙刷刷毛拔出法和直接涮洗法收集口腔黏膜脱落细胞,分别用Chelex-100法和DNA IQ试剂盒提取DNA进行PCR扩增及STR分型.结果 牙刷刷毛拔下后收集口腔黏膜脱落细胞检测STR 9个以上基因座成功率明显高于直接涮洗法,差异具统计学意义(P<0.05).Chelex-100法和DNA IQ试剂盒提取法之间差异无统计学意义(P>0.05).结论 牙刷刷毛拔出法较直接涮洗法收集口腔黏膜脱落细胞更有效.  相似文献   

6.
目的评估新建立的23个STR复合扩增体系EX23的法医学应用价值。方法使用磁珠法提取样本DNA,应用23个STR复合扩增体系进行扩增,ABI3130XL遗传分析仪对扩增产物进行电泳,GeneMapperID 3.2软件进行基因分型,对法医学应用参数、灵敏度、种属、脱落细胞检材及降级检材分型效果进行观察,并与Sinofiler试剂盒比较。结果 DNA模板量在0.05~1.00ng时,各基因座分型结果清晰准确,均衡性好、特异性强。应用该复合扩增体系检验混合样本、降解检材及脱落细胞检材,均能获得正确的分型结果。统计结果显示该23个STR基因座累计个人识别(TDP)率达0.999999999,三联体累计非父排除率(CPE)达0.999999997。结论新建立的23个STR复合扩增体系分型效果良好,在广东地区汉族人群中具有高度多态性,可满足日常法医鉴定的需要。  相似文献   

7.
目的对汽车方向盘及变速杆把手上的皮肤脱落细胞进行STR检验研究。方法用EZ-tape采集车辆方向盘及变速杆上的脱落细胞,Chelex-100法与磁珠法结合提取DNA,延长保温时间。定量后调整PCR反应体系,适当增加PCR循环数,增加PCR产物量及延长进样时间进行电泳检测,使用GeneMapperIDV3.2软件进行STR分型。同时,对比使用多重置换扩增技术对提取的DNA进行全基因组扩增。结果对33份车辆方向盘和变速杆上脱落细胞的检测,其中19份检出全部基因座的基因分型结果,9份检出部分基因型,5份未检出DNA分型结果。而利用多重置换扩增技术未获得满意图谱。结论本研究建立的脱落细胞收集、DNA提取、PCR扩增及检测方法适合于车辆上脱落细胞的检验,其结果优于使用多重置换扩增技术获得的分型。  相似文献   

8.
车辆上脱落细胞STR检验   总被引:2,自引:1,他引:1  
袁丽  鲁涤  杨雪  印佳 《证据科学》2010,18(1):120-124
目的对汽车方向盘及变速杆把手上的皮肤脱落细胞进行STR检验研究。方法用EZ-tape采集车辆方向盘及变速杆上的脱落细胞,Chelex-100法与磁珠法结合提取DNA,延长保温时间。定量后调整PCR反应体系,适当增加PCR循环数,增加PCR产物量及延长进样时间进行电泳检测,使用GeneMapperIDV3.2软件进行STR分型。同时,对比使用多重置换扩增技术对提取的DNA进行全基因组扩增。结果对33份车辆方向盘和变速杆上脱落细胞的检测,其中19份检出全部基因座的基因分型结果,9份检出部分基因型,5份未检出DNA分型结果。而利用多重置换扩增技术未获得满意图谱。结论本研究建立的脱落细胞收集、DNA提取、PCR扩增及检测方法适合于车辆上脱落细胞的检验,其结果优于使用多重置换扩增技术获得的分型。  相似文献   

9.
目的采用激光显微捕获技术(LCM)捕获尿液脱落细胞,并进行STR分型。方法收集10份健康成人尿液样本,根据储存时间分组,其中新鲜尿液组(≤24h)分别采用Chelex-100及LCM联合DNA IQTM提取法提取DNA,储存尿液组(〉24h)再分为4℃组和室温组,分别在4~30d内不同时间点采用LCM联合DNA IQTM提取法提取DNA;各组提取的模板DNA进行扩增及SRT分型检验。结果新鲜尿液组采用LCM联合DNA IQTM提取法提取DNA,所有样本均可检出全部基因座(16个),采用Chelex-100法则在部分基因座上出现等位基因丢失、非特异性扩增、峰值低等现象;4℃储存10d和室温储存4d以内的尿液经检验可明确判读12个以上基因座,4℃20~30d及室温7d,可检出7个以上基因座。结论 LCM技术可用于尿液检材的DNA分型检验,且检材应尽可能4℃保存并尽快检验。  相似文献   

10.
浓缩DNA法结合miniSTR分型技术检验微量DNA   总被引:1,自引:0,他引:1  
Gu LH  Dong Y  Zhang C  Xu Y  Chen RH  Hu W  Chen LK  Zhou HG 《法医学杂志》2010,26(5):361-363
目的优化低拷贝数DNA STR分型方法。方法对采用磁珠法或Chelex-100法提取DNA,Identi-filer试剂盒扩增,未获得分型结果的日常检案检材,采用物理浓缩法或过柱浓缩法浓缩DNA,采用miniFilerTM试剂盒再次扩增分型。结果 127例检材中,47例磁珠法提取DNA未获得分型的样品,分型成功率为36%;80例Chelex-100法提取DNA未获分型的样品,分型成功率为30%。结论采用浓缩法和miniFilerTM试剂盒,可以提高日常检案中低拷贝数检材的STR检验分型成功率。  相似文献   

11.
DNA IQ磁珠法结合Maxwell~(TM) 16自动仪提取接触DNA   总被引:1,自引:0,他引:1  
目的研究DNA IQ磁珠法结合MaxwellTM 16自动仪对接触DNA提取的应用价值。方法 151份案件接触DNA检材95℃裂解后,采用DNA IQ磁珠法结合MaxwellTM 16自动仪提取DNA,然后进行DNA定量和STR分型检测,统计各种类型的接触DNA含量I、PC CT值和STR分型成功率。结果 151份案件接触DNA检材中,除果核平均DNA获得量为9.51ng以外,其它接触检材的平均DNA获得量均大于10ng,烟蒂检验成功率最高为93%,果核检验成功率较低,为60%。所有DNA样品的IPC CT值均在27左右,纯度高。结论大部分接触DNA检材采用DNA IQ磁珠法结合MaxwellTM 16自动仪可提取到足以进行STR分型的DNA。  相似文献   

12.
A 96-channel microfabricated capillary array electrophoresis (muCAE) device was evaluated for forensic short tandem repeat (STR) typing using PowerPlex 16 and AmpFlSTR Profiler Plus multiplex PCR systems. The high-throughput muCAE system produced high-speed <30-min parallel sample separations with single-base resolution. Forty-eight previously analyzed single-source samples were accurately typed, as confirmed on an ABI Prism 310 and/or the Hitachi FMBIO II. Minor alleles in 3:1 mixture samples containing female and male DNA were reliably typed as well. The instrument produced full profiles from sample DNA down to 0.17 ng, a threshold similar to that found for the ABI 310. Seventeen nonprobative samples from various evidentiary biological stains were also correctly typed. The successful application of the muCAE device to actual forensic STR typing samples is a significant step toward the development of a completely integrated STR analysis microdevice.  相似文献   

13.
An automatic and rapid DNA typing system was employed for personal identification, using fragmentary tissue samples from victims in an airplane accident. Two victims were crushed into small pieces, and 33 samples suspected to belong to them were recovered from under the sea. From each sample, 10 mg was used for testing. The parents' bloods of two presumptive victims were also examined. DNA extraction from samples was performed by the NaI method, and the obtained DNA samples were analyzed with the ABI PRISM system. Among 33 samples, 31 samples were identified to be human tissues, possibly from two victims. The other two samples seemed to be parts of marine animals. ABO blood group, STR polymorphism, and mitochondrial DNA polymorphism typing were possible in every examined human sample. Two victims' fragmentary tissues were identified by determining ABO genotype, STR type and mitochondrial DNA type. The system we employed enabled an accurate typing of many fragmentary samples in a short time, thus contributing to the fast and secure identification of many victims in such cases as big air accidents.  相似文献   

14.
Chewed betel-quid (BQ) residues are often considered vital biological evidence at crime scenes, since the human DNA extracted from the residues is actually from buccal epithelial cells and can be associated with suspects. BQ-chewing is also a risk factor for oral diseases and/or cancers. Archived medical oral-specimens can be used to identify specific individuals under adverse conditions, although STR markers are known to be unstable in various tumor tissues. This study evaluates the DNA stability of forensic marker systems in BQ-chewers' oral epithelial cells, and in archived clinical specimens of oral cancer patients. The genotypes of oral and paired peripheral blood samples in 200 subjects were compared, using the commercialized typing systems of HLA-DQA1, PM (including LDLR, GYPA, HBGG, D7S8, and GC loci), and AmpFlSTR markers (including 9 STR loci and the Amelogenin gene). The 100 healthy BQ-chewers had consistent oral swab and paired blood sample genotypes analyzed withboth DQA1/PM and STR marker systems. In the 100 oral cancer patients, one discordant result at D7S8 was found in the 600DQA1/PM-marker loci, and 25 allelic alterations with expansion or contraction were detected in the 900 STR loci. The findings herein suggest that when cancerous specimens were tested, the HLA-DQA1/PM system with point polymorphism appears more reliable than the STR system with length polymorphism. Our results also indicate that healthy BQ-chewers' oral cotton swabs containing buccal epithelial cells are useful for forensic purposes using the HLA-DQA1, PM, and STR marker systems.  相似文献   

15.
法医物证DNA自动化检验技术体系的研究   总被引:1,自引:1,他引:0  
目的建立自动化工作站同步提取不同种类涉案法医生物检材DNA的新方法。方法选用TECAN Freedom EVO100.4、75—2型自动化提取、加样工作站,采用磁珠法及Chelex-100法对各类涉案生物检材进行DNA提取、PCR扩增、毛细管电泳检测其STR分型,进行比较测试。在“全国公安机关DNA数据库应用系统”中建立并应用实验室信息管理系统(LIMS)模拟实施规范化DNA检案。结果1552份各类检材,采用工作站-磁珠法提取DNA效果最佳,STR检测成功率为95%,工作站-Chelex法为88%;二者分别与其手工提取法比较,成功率无明显差异。92个样本同期检测,自动化工作站较手工操作DNA检案时间可缩减1.25倍。结论工作站域珠法提取涉案检材DNA,可获得满意的STR分型结果。应用LIMS管控,可有效防控污染,明显提高检案效率及鉴定质量。  相似文献   

16.
目的:探讨氨基比林血痕预试验处理血痕后样本DNA含量的变化及对STR分型检测的影响。方法10名健康无关个体EDTA抗凝血液制成滤纸血痕,氨基比林血痕预试验检测,按试验后血样干燥保存时间分30 min、1 h、3 h、6 h、12 h、24 h共6个实验组,并采用磁珠法、QIAcube DNA纯化法、Chelex-100法三种方法提取样本DNA,应用荧光定量PCR检测样本DNA含量,PCR-STR荧光技术进行STR分型。结果提取方法相同时,氨基比林血痕预试验后血样随干燥保存时间的延长,样本DNA含量呈逐渐降低的趋势。保存时间相同时,不同DNA提取方法间,样本DNA含量差异也有统计学意义。90.56%样本均可获得16个STR基因座明确分型。结论氨基比林血痕预试验对血痕样本DNA有损伤,24 h内多可获有效STR分型。磁珠法提取样本DNA进行STR分型,效果最好。  相似文献   

17.
STR typing and mitochondrial DNA (mtDNA) sequencing were performed on the matter adhering to an earphone found at a crime scene. Experimental studies were carried out using the earphones provided by volunteers. By means of immunohistochemistry, keratinocytes and a portion of nucleated epithelial cells were proven to exist in the contents from the earphones. DNA was extracted by means of the phenol/chloroform method, and the low quantity of extracted DNA was found to be highly degraded. Six STR loci, CSFIPO, TPOX, TH01, F13A01, FESFPS and vWA, were PCR amplified and typed by using two triplex systems (CTT and FFv Multiplexes, Promega, WI), and an amelogenin locus was determined as well. Although partial profiles were observed in some experimental samples, all STR loci could be typed when a considerable amount of high molecular weight DNA was obtained (>0.5 ng/microL). Amplification and sequencing of mtDNA hypervariable region I(15997-16401) and hypervariable region 11(29-408) were all successful. The mitochondrial DNA sequence of the actual case sample, comprising two hypervariable regions and a total of 785 base pairs, showed eight mutations and two insertions with respect to the standard published reference sequence. The genotype was unique in the three published Japanese databases. These results suggest that it is possible to analyze mtDNA from minute amounts of materials and from degraded materials more effectively and routinely in forensic practice.  相似文献   

18.
目的探索DNA IQTMSYSTEM在疑难指甲DNA提取中的应用。方法 15份疑难指甲采用Chelex方法检验没有成功获得STR分型图谱,采用DNA IQTMSYSTEM提取法并纯化,采用Identifiler PLUS试剂盒进行复合扩增,产物经ABI3130XL型DNA基因分析仪检测。结果成功获得15例疑难指甲的STR基因座DNA分型。结论 DNA IQTMSYSTEM方法能快速、有效提取疑难指甲DNA进行STR分型。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号