首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
目的研究多重置换扩增(multiple displacement amplification,MDA)在含抑制物检材中的抗抑制能力,与磁珠法纯化检材相比较,证明其在法医学中的应用及意义。方法将不同浓度血红素和腐殖酸与样本DNA进行混合,分为MDA处理组、磁珠法处理组和空白对照组,PCR-STR单基因座D3S1358扩增联合聚丙烯酰胺凝胶电泳检测,并应用Amp F詛STR誖IdentifilerTMPlus试剂盒联合毛细管电泳检测。结果血红素质量浓度大于1 ng/μL或腐殖酸质量浓度大于0.1 ng/μL时,空白对照组经单基因座STR检测不能得到扩增产物;磁珠法处理组血红素质量浓度大于100 ng/μL或腐殖酸浓度大于1 ng/μL时,不能够得到扩增产物;MDA处理组各浓度抑制物均能成功扩增,完全不受抑制物影响。结论 MDA技术可消除血红素及腐殖酸的抑制作用,其抗抑制能力优于磁珠法纯化DNA,具有一定的法医学应用意义。  相似文献   

2.
《中国法医学杂志》2017,(6):614-617
目的利用TE-MAGS在TECAN自动化工作站上结合磁珠试剂盒,定量研究微量DNA提取回收效率和纯化能力。方法 0.1~1ng9947A和混有6种常见PCR抑制剂的1ng9947A,经自动化提取后进行荧光定量和STR分型,定量分析回收效率和纯化能力。结果 0.1~1ng9947A提取后实际回收效率在38.92~60.01%之间,0.3ng以上9947A提取扩增后可以得到完整的STR图谱。胆汁酸盐、胶原质、尿素去除效率大于94.5%,血红素、黑色素、腐殖酸去除效率分别为97.5%、97.85%、82.14%。结论 TE-MAGS磁珠法对微量DNA回收效率较高,纯化能力较强,适合微量DNA提取。  相似文献   

3.
法医物证DNA自动化检验技术体系的研究   总被引:1,自引:1,他引:0  
目的建立自动化工作站同步提取不同种类涉案法医生物检材DNA的新方法。方法选用TECAN Freedom EVO100.4、75—2型自动化提取、加样工作站,采用磁珠法及Chelex-100法对各类涉案生物检材进行DNA提取、PCR扩增、毛细管电泳检测其STR分型,进行比较测试。在“全国公安机关DNA数据库应用系统”中建立并应用实验室信息管理系统(LIMS)模拟实施规范化DNA检案。结果1552份各类检材,采用工作站-磁珠法提取DNA效果最佳,STR检测成功率为95%,工作站-Chelex法为88%;二者分别与其手工提取法比较,成功率无明显差异。92个样本同期检测,自动化工作站较手工操作DNA检案时间可缩减1.25倍。结论工作站域珠法提取涉案检材DNA,可获得满意的STR分型结果。应用LIMS管控,可有效防控污染,明显提高检案效率及鉴定质量。  相似文献   

4.
国产磁珠结合自动化工作站批量提取生物检材DNA的应用   总被引:7,自引:4,他引:3  
目的建立国产磁珠结合自动化工作站批量提取案件中生物检材DNA的方法。方法采用国产磁珠结合Bio-Robert Universal System自动化工作站对案件中常见的生物样本进行DNA提取,检测Identifiler系统16个STR基因座,在ABI3130XL遗传分析仪上进行STR分型。其中210份样品同时在ABI7500型荧光定量PCR仪上进行定量。结果9100份10类生物检材应用国产磁珠结合自动化工作站,大部分可提取到足够的DNA进行STR检验。STR检验成功率最高的为口腔拭子、肌肉,达100%,接触细胞检材的成功率较低,为50.0%。结论国产磁珠结合自动化工作站可用于案件中常见的大部分生物样本的DNA提取。  相似文献   

5.
目的比较3种常见的接触检材前处理方式对磁珠法提取DNA效果的影响。方法收集烟蒂、牙刷、纱线手套各10份;分别采用95℃、70℃直接裂解和TNE、SDS、PK预消化方式进行前处理,再用磁珠法提取纯化DNA,并进行DNA定量,统计提取的接触DNA量和IPC CT值;同时用Sinofiler复合扩增系统进行STR分型检测。结果 3种方法前处理后用磁珠提取的DNA纯度均较高I,PC CT值在26.63~27.19之间。用预消化法获得的DNA量高于裂解法,而95℃裂解与70℃裂解方法提取的DNA量无显著性差异。STR扩增检测结果亦表明,采用预消化法处理的样品STR分型成功率高于裂解法9,5℃与70℃裂解方法处理的样品STR分型成功率无显著性差异。结论人体接触检材采用预消化磁珠法提取DNA,有助于提高STR检验成功率。  相似文献   

6.
两种国产磁珠试剂盒对常见PCR抑制物去除效果比较   总被引:1,自引:1,他引:0  
目的比较国产博坤磁珠试剂盒和Wawasye磁珠试剂盒对法医学常见PCR抑制物的去除效果。方法选择6种常见PCR抑制物,胆汁酸盐、胶原质、腐殖酸、血红素、黑色素和尿素,分别将其与K562 DNA混合后,采用Identifiler试剂盒进行分型,以恰好抑制K562 DNA所有26个不同等位基因的抑制物浓度为标准添加浓度,在此基础上提高每种PCR抑制物的浓度,分别采用两种磁珠试剂盒对混有抑制物的标准品DNA进行纯化处理后,再进行PCR扩增和STR分型检测,统计STR基因座等位基因检出个数。结果分别混有1×、2×和4×标准添加浓度各种抑制物的K562 DNA经博坤磁珠试剂盒纯化后,均可检出所有STR基因座的全部等位基因;经Wawasye磁珠试剂盒纯化后,混有胆汁酸盐、胶原质、血红素和尿素的DNA均可检出所有STR基因座的全部等位基因,而混有腐殖酸和黑色素的DNA未检出任何等位基因。结论除Wawasye磁珠试剂盒无法有效去除腐殖酸和黑色素外,两种国产磁珠试剂盒对大多数PCR抑制物均具有良好去除效果。  相似文献   

7.
Chelex法和两种磁珠法提取接触DNA效果的比较   总被引:1,自引:0,他引:1  
目的比较Chelex法、DNA IQ磁珠法、EQ国产磁珠法对接触DNA的提取效果。方法将稀释为10ng、100ng的标准品DNA,分别采用Chelex法、DNA IQ磁珠法、EQ国产磁珠法处理;对30例烟蒂和30例牙刷分别采用Chelex法、DNA IQ磁珠法和EQ国产磁珠法提取DNA,然后进行PCR定量和STR检测。结果Chelex法对DNA的提取无损失,DNA IQ磁珠法、EQ国产磁珠法对DNA的提取均有不同程度的损失;烟蒂、牙刷等检材采用Chelex法提取的接触DNA量和IPC CT值显著高于IQ磁珠法、EQ国产磁珠法,但STR检验成功率却低于IQ磁珠法、EQ国产磁珠法。2种磁珠法提取的DNA量、IPC CT值和STR检验成功率无显著性差异。结论污染轻、杂质少的接触DNA检材,用Chelex法提取最为方便快捷;IQ磁珠法、EQ国产磁珠法更适合污染接触DNA检材的提取及自动化操作。  相似文献   

8.
目的建立对衣物类生物检材STR检验的有效自动提取纯化方法。方法对100例衣物类生物检材用EZ1DNA Investigator试剂盒、EZ1Advanced XL工作站的Large-Volume程序(大体积法)进行提取纯化,AmpFLSTR~Identifiler~Plus荧光STR复合扩增,3500x L型遗传分析仪分析结果。结果 69份检材中检出了单一DNA分型结果,9份检出了混合基因型,22份未检出基因型。结论该方法对衣物类生物检材DNA提取纯化后进行荧光STR检测,可应用于法庭科学实践。  相似文献   

9.
DNA IQ磁珠法结合Maxwell~(TM) 16自动仪提取接触DNA   总被引:1,自引:0,他引:1  
目的研究DNA IQ磁珠法结合MaxwellTM 16自动仪对接触DNA提取的应用价值。方法 151份案件接触DNA检材95℃裂解后,采用DNA IQ磁珠法结合MaxwellTM 16自动仪提取DNA,然后进行DNA定量和STR分型检测,统计各种类型的接触DNA含量I、PC CT值和STR分型成功率。结果 151份案件接触DNA检材中,除果核平均DNA获得量为9.51ng以外,其它接触检材的平均DNA获得量均大于10ng,烟蒂检验成功率最高为93%,果核检验成功率较低,为60%。所有DNA样品的IPC CT值均在27左右,纯度高。结论大部分接触DNA检材采用DNA IQ磁珠法结合MaxwellTM 16自动仪可提取到足以进行STR分型的DNA。  相似文献   

10.
浓缩DNA法结合miniSTR分型技术检验微量DNA   总被引:1,自引:0,他引:1  
Gu LH  Dong Y  Zhang C  Xu Y  Chen RH  Hu W  Chen LK  Zhou HG 《法医学杂志》2010,26(5):361-363
目的优化低拷贝数DNA STR分型方法。方法对采用磁珠法或Chelex-100法提取DNA,Identi-filer试剂盒扩增,未获得分型结果的日常检案检材,采用物理浓缩法或过柱浓缩法浓缩DNA,采用miniFilerTM试剂盒再次扩增分型。结果 127例检材中,47例磁珠法提取DNA未获得分型的样品,分型成功率为36%;80例Chelex-100法提取DNA未获分型的样品,分型成功率为30%。结论采用浓缩法和miniFilerTM试剂盒,可以提高日常检案中低拷贝数检材的STR检验分型成功率。  相似文献   

11.
应用自动化工作站提取常见生物样本DNA   总被引:7,自引:2,他引:5  
目的建立使用自动化工作站提取法医案件生物样本DNA的方法。方法选用Biomek 3000自动化工作站,采用DNA IQTM系统及Chelex法对法医案件中常见生物样本进行DNA提取,荧光定量技术进行定量,PCR扩增16个STR基因座并与手工提取方法比较。结果与手工提取方法进行比较,选用自动化工作站结合使用DNAIQTM系统及Chelex法提取DNA可获得满意的STR检验结果。结论自动化工作站可用于法医案件中常见生物样本的DNA提取。  相似文献   

12.
目的比较有机法+QIAquick纯化法和DNA IQ磁珠法对陈旧骨骼和牙齿DNA的纯化效果。方法选择10份陈旧骨骼和12份牙齿样本,进行消化后分别采用有机法+QIAquick纯化法和DNA IQ磁珠法进行提取纯化,进行DNA定量后用SinofilerTM试剂盒进行检测。结果 2种方法纯化的骨骼、牙齿DNA的IPC CT值无显著差异。有机法+QIAquick纯化法纯化的骨骼、牙齿DNA平均浓度分别为0.180ng/μL±0.068ng/μL和0.132ng/μL±0.027ng/μL,所有样品均获得全部基因分型。DNA IQ磁珠法纯化的DNA平均浓度分别为0.038ng/μL±0.028ng/μL和0.036ng/μL±0.007ng/μL,有5份骨骼和6份牙齿样本仅获得部分基因分型或未能分型。结论有机法+QIAquick纯化法对陈旧骨骼、牙齿DNA的纯化效果优于DNA IQ磁珠法。  相似文献   

13.
The current backlog of casework is among the most significant challenges facing crime laboratories at this time. While the development of next-generation microchip-based technology for expedited forensic casework analysis offers one solution to this problem, this will require the adaptation of manual, large-volume, benchtop chemistry to small volume microfluidic devices. Analysis of evidentiary materials from rape kits where semen or sperm cells are commonly found represents a unique set of challenges for on-chip cell lysis and DNA extraction that must be addressed for successful application. The work presented here details the development of a microdevice capable of DNA extraction directly from sperm cells for application to the analysis of sexual assault evidence. A variety of chemical lysing agents are assessed for inclusion in the extraction protocol and a method for DNA purification from sperm cells is described. Suitability of the extracted DNA for short tandem repeat (STR) analysis is assessed and genetic profiles shown. Finally, on-chip cell lysis methods are evaluated, with results from fluorescence visualization of cell rupture and DNA extraction from an integrated cell lysis and purification with subsequent STR amplification presented. A method for on-chip cell lysis and DNA purification is described, with considerations toward inclusion in an integrated microdevice capable of both differential cell sorting and DNA extraction. The results of this work demonstrate the feasibility of incorporating microchip-based cell lysis and DNA extraction into forensic casework analysis.  相似文献   

14.
Abstract: Automated platforms used for forensic casework sample DNA extraction need to be versatile to accommodate a wide variety of sample types, thus protocols frequently need modification. In this study, DNA IQ? methods previously developed for the Biomek® 2000 Automation Workstation were adapted for the Teleshake Unit using normal volumes and all deepwell extraction, and a large volume DNA IQ? method developed. DNA purification without detectable contamination of adjacent reagent blanks is reported in the extraction of tissue samples containing several micrograms of DNA. Sensitivity and contamination studies demonstrated similar performance with the manual organic extraction method for bloodstain dilution samples. Mock casework samples demonstrated the effectiveness of the Teleshake and Teleshake large volume methods. Because of the performance and increased versatility of the DNA IQ? extraction with these modifications, the Teleshake Unit has been implemented in both normal and large volume automated DNA extractions at the Virginia Department of Forensic Science.  相似文献   

15.
An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.  相似文献   

16.
目的测试DNA TyperTM15 plus直扩试剂盒的技术性能指标,评价其在DNA数据库建设中的应用价值。方法采用DNA TyperTM15 plus试剂盒,并使用IdentifilerTM和DNA TyperTM15试剂盒进行比较,设定不同体系和引物量、不同退火温度和循环次数以进行方法验证;设定不同模板量标准品、不同比例混合样本,取猪、狗、兔等动物的血液样品,血痕、骨骼、唾液斑等常见检材样本以及不同建库样本,以验证试剂盒灵敏度、特异性、稳定性以及混合样本、常见检材及建库样本的检测能力。结果直扩试剂盒分型结果准确,重复性好,灵敏度可达0.125ng,不同批次间试剂检测结果稳定,对不同检材有很好的适应性。10μL扩增体系时FTA卡和加强型血液采集卡取样直径应为0.5mm,而血滤纸、血液采集卡样本和经典型血液采集卡取样直径应为1.0mm。结论 DNA TyperTM15 plus直扩试剂盒的性能可以满足DNA数据库建设及检案的需要,可在相关实验中选择使用。  相似文献   

17.
粪便DNA提取及检验   总被引:3,自引:0,他引:3  
目的 研究人类粪便DNA的提取和检验方法。方法  8人份粪便样本 ,磁珠法提取DNA后 ,进行STR复合扩增和mtDNAHVI区测序分析。结果 用 2种方法提取的粪便DNA ,STR复合扩增检验均未获成功 ;方法1提取的粪便DNA有 6个样本、方法 2有 7个样本获得了清晰可读的mtDNAHVI区序列 ,并与唾液对照样本DNA的序列完全一致。结论 用本文建立的方法提取粪便DNA ,不适于STR分析 ,可通过mtDNA测序分析进行检验。  相似文献   

18.
Analysis of short tandem repeat (STR) markers currently represents the most useful instrument in the field of forensic genetics. The problem with forensic material is the degradation of the sample material. In recent years, several papers have demonstrated that short amplicon STR (miniSTR) represents one of the most useful tools for analyzing degraded DNA samples.In the present study, we attempted to develop a short amplicon STR multiplex system (autosomal and y-chromosomal) for analyzing degraded DNA using some newly designed primer sets for a multiplex polymerase chain reaction (PCR) systems for typing.An assay of degraded DNA samples using the designed multiplex systems, including artificially degraded samples and degraded forensic casework samples, proved remarkably effective. Comparing the multiplex with commercial kits, first results show a well success rate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号