首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A population study on 13 tetra- and pentameric STR loci (D3S1358, VWA, D8S1179, D21S11, D18S51, D16S539, D2S1338, D19S433, THO1, FGA, ACTBP2 (SE33), Penta D and Penta E) was performed with Romanians from the Bucharest area.  相似文献   

2.
Allele frequencies for the 15 STR loci (D3S1358, TH01, D21S11, D18S51, Penta E, D5S818, D13S317, D7S820, D16S539, CSF1PO, Penta D, vWA, D8S1179, TPOX, FGA) included in the PowerPlex 16 kit were obtained from a multiethnic sample of 100 unrelated individuals born in Bosnia and Herzegovina.  相似文献   

3.
Allele frequencies for the nine tetrameric short tandem repeats (STR) loci D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820 (AmpFlSTR Profiler Plus PCR amplification kit, PE Applied Biosystems) and two pentameric STR loci Penta D and Penta E (PowerPlex 16 system, Promega Corporation) were determined in a population sample of unrelated China Han.  相似文献   

4.
In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.  相似文献   

5.
Allele frequencies for the 15 STR locus of PowerPlex 16 were analyzed in 95 healthy unrelated individuals belonging to five important population groups inhabiting different part of India. Fifteen loci studied are Penta E, D18S51, D21S11, THO1,D3S1358, FGA, TPOX, D8S1179, vWA, Amelogenin, Penta D, CSF1PO, D16S539, D7S820, D13S317 and D5S818. In addition of all tetra nucleotide loci, two penta nucleotide loci Penta D and Penta E of the studied system are also found highly polymorphic in all the five studied populations of India. These loci are found highly informative in solving paternity cases and other forensic testing in studied population.  相似文献   

6.
目的 研究PentaD和PentaE基因座分型引物设计 ,调查PentaD和PentaE基因座在武汉汉族人群中的遗传多态性。方法 用重新设计的PentaD和PentaE基因座分型引物 ,采用热启动PCR和PAGE技术对 2 81名武汉地区汉族无关个体进行分型调查 ,并将其分型结果与Promega公司的PowerPlexTM16系统荧光标记复合扩增试剂盒分型结果进行比较。结果 新设计引物扩增产物的片段大小范围分别为 15 3~ 198bp和 10 7~ 2 12bp ,其分型结果与PowerPlexTM16系统的分型结果完全一致 ,且用银染法检测的灵敏度显著提高 (由 0 5ng提高到 0 2ng)。PentaD和PentaE基因座在武汉汉族群体分别检出 10个和 2 1个等位基因 ,其基因型频率分布均符合Hardy Weinberg平衡。家系调查证实了其等位基因的传递符合孟德尔遗传规律。两基因座的个体识别能力 (DP)分别为 0 92 62、 0 9860 ,非父排除率 (PE)分别为 0 665 1、 0 83 2 5。结论 新设计引物用于PentaD和PentaE基因座的分型检测准确可靠 ,两基因座多态性程度高 ,在法医学个人识别和亲子鉴定中具有使用价值。  相似文献   

7.
The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.  相似文献   

8.
Allele frequencies of 13 tetrameric short tandem repeat (STR) loci (D3S1358, TH01, D21S11, D18S51, D5S818, D13S317, D7S820, D16S539, CSF1PO, vWA, D8S1179, TPOX, FGA) and 2 pentameric short tandem repeat loci (Penta E and Penta D) included in the PowerPlex 16 kit were obtained from a sample of 116 unrelated individuals in Van-A?ri districts of the Eastern Anatolia region of Turkey. The expected performance of these loci for personal identification and paternity testing in this population was estimated.  相似文献   

9.
Allele frequencies for 18 STR autosomal loci (D3S1358, VWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820, D16S539, TH01, TPOX, CSF1PO, Penta D, Penta E, D19S433, D2S1338 and SE33) were obtained from a sample of 191-500 unrelated individuals from Costa Rica, Central America.  相似文献   

10.
Over 1500 population database samples comprising African Americans, Caucasians, Hispanics, Native Americans, Chamorros and Filipinos were typed using the PowerPlex 16 and the Profiler Plus/COfiler kits. Except for the D8S1179 locus in Chamorros and Filipinos from Guam, there were eight examples in which a typing difference due to allele dropout was observed. At the D8S1179 locus in the population samples from Guam, there were 13 examples of allele dropout observed when using the Profiler Plus kit. The data support that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples that are for use in CODIS. In addition, allele frequency databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic.  相似文献   

11.
PowerPlex~(TM) 16体系在中国人群中罕见等位基因及其类型   总被引:1,自引:2,他引:1  
目的 分析PowerPlexTM 16体系基因座在中国人群中的罕见等位基因及其类型。方法 应用PCR-STR和DNA序列分析技术,对4650个无关个体在15个STR基因座中的罕见等位基因进行检测。结果 在PowerPlexTM16体系中的D7S820、D16S539、Penta E基因座,检测到2种类型的罕见等位基因,而TH01、D21S11、D5S818、D13S317、Penta D、D8S1179、TPOX、FGA基因座检测出1种类型。其等位基因频率均较低(0.215‰-7.097‰)。结论 超出ladder范围的罕见等位基因序列比相邻等位基因增加(或减少)1个或数个重复单位,因碱基的插入或缺失的罕见等位基因出现在两等位基因之间。  相似文献   

12.
Frequency data of short tandem repeats loci included in the SGM Plus kit and on two pentanucleotide STR loci: Penta E and Penta D [Profiles DNA 2 (1998) 2] included in the PowerPlex16 kit were collected from a sample of 400 (for SGM Plus) and 91 (for Penta E and Penta D) random, unrelated individuals born in the South Poland region.  相似文献   

13.
Allele and haplotype frequencies of 17 chromosome STR loci, 15 of them included in the kit PowerPlex 16 System from Promega, were determined in a sample of unrelated males from Madeira and Porto Santo Islands. PowerPlex 16 includes STRs not studied before in the Madeira population. The-kit includes two new allele markers (Penta D and Penta E), which proved to be extremely useful for paternity testing (PD = 0.952 and 0.977, respectively). The study revealed that the Madeira population does not differ from that of the north Portugal. Nevertheless, some loci presented alleles found in sub-Saharan and North European populations which were not reported so far in Portugal.  相似文献   

14.
Allele and haplotype frequencies of 15 chromosome STR loci included in the kit PowerPlex16 System from Promega, were determined in a sample of unrelated males from Guiné-Bissau, a country from the west African coast. All individuals were subjected to an interview in order to make sure that their ancestors belonged to the same ethnic group. This way we intended to look for possible inter-ethnic differences. PowerPlex 16 includes STRs not studied before in any multi-ethnic population. The kit includes two new allele markers (Penta D and Penta E), which are very useful either in forensics or population genetic studies. The Guinean population presents significant differences when compared with other African populations.  相似文献   

15.
Allele and haplotype frequencies of 16 chromosome STR loci, 15 of them included in the Kit PowerPlex16 System from Promega were determined in a sample of unrelated males from the A?ores Archipelago. All subjects were subjected to an interview in order to make sure that their ancestors belonged to the same island at least back to three generations. This way we intended to look for possible inter-islands differences. PowerPlex16 includes STRs not studied before in the A?ores population. The Kit includes two new allele markers (Penta D and Penta E), which proved to be extremely useful for paternity testing (PD=0.921 and 0.971, respectively). The study revealed that the A?ores population is considerable different from the previous studied Madeira population, but does not differ from that of the north Portugal. Nevertheless, some loci presented alleles not previously reported for Portugal.  相似文献   

16.
Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex 16 and the Profiler Plus COfiler kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.  相似文献   

17.
Allele frequencies for 16 short tandem repeats (STR) loci were determined with a sample of 230-300 unrelated individuals from the population of Rio de Janeiro, Brazil. The loci are the most commonly used in forensic and paternity testing, being analysed by the Identifiler (Applied Biosystems) and PowerPlex 2.1 (Promega) commercial kits. It was proved that Penta E and D18S51 are the most polymorphic loci.  相似文献   

18.
DNA profiles of forensic cases of Córdoba Province, Argentina, typed by PowerPlex 16 kit (Promega), have shown in the Penta D locus few samples with a variant allele migrating as an off ladder between alleles 9 and 10. In order to determine the molecular basis of the new variant allele, three samples were subject to polymerase chain reaction amplification of the Penta D locus by monoplex, and were further purified and sequenced. The sequence analysis revealed that the off ladder allele has ten repeats motifs AAAGA as allele 10, with three nucleotides (TAA) deletion in the 3' flanking region, 128 nucleotides after the last repeat. Therefore, the variant allele could be explained by a deletion of allele 10, and was designated 9.2. Mse I digestion assay allows to corroborate allele 9.2 without sequencing. A population study in Córdoba Province indicates that allele 9.2 of Penta D locus has a frequency of 0.0063.  相似文献   

19.
Allele distribution of the 15 STR loci of Powerplex 16 Multiplex System were studied in four predominant population groups of South India for evaluating their significance in human identification and population study: Iyengar Brahmin (65), Gowda (59), Lingayat (98) and Muslim (45) from the state of Karnataka. The loci analyzed are--D3S1358, THOI, D2ISI I, D18S51, D5S818, Penta E, D13S317, D7S820, D16S539, CSFIPO, Penta D, vWA, D8S179, TPOX and FGA. Out of 15 STR loci Penta D and D18S51 were found highly polymorphic in the studied populations.  相似文献   

20.
Validation of a 16-locus fluorescent multiplex system   总被引:24,自引:0,他引:24  
STR multiplexes have been indispensable for the efficient genotyping of forensic samples. The PowerPlex 16 System contains the coreCODIS loci, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, THOI, TPOX, vWA, the sex determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. This multiplex satisfies the locus requirements for most national databases and is the most efficient currently available system due to its single PCR amplification. To provide the groundwork for judicial acceptance, including the publication of primer sequences, and to evaluate laboratory-to-laboratory variation, a developmental validation for casework on this commercially available system was performed in 24 laboratories and produced the following conclusions. Amplification was reliable on a variety of thermal cyclers and product could be analyzed on either an ABI PRISM 310 Genetic Analyzer or an ABI PRISM 377 DNA Sequencer. Genotyping using single source samples was consistent between 0.25 and 2 ng of input DNA template with a few laboratories obtaining complete genotypes at 0.0625 ng. However, heterozygote allele imbalance (<60% peak height balance) caused by stochastic effects was observed at a rate of 13% with 0.125 ng DNA and 22% at 0.0625 ng DNA. Mixture analyses were done using a total of 1 ng of DNA template. Most alleles were detected in mixtures of 4 to 1 and some minor alleles were detected in mixtures of 19 to 1. Optimum amplification cycle number was dependent on the sensitivity of the detection instrument used and could also be adjusted to accommodate larger amounts of DNA on solid supports such as FTA paper. Reaction conditions including volume, annealing temperature, and concentrations of primer, AmpliTaq Gold, and magnesium were shown to be optimal yet robust enough to withstand moderate variations without affecting genotype analysis. Environmental, matrix and standard source analyses revealed an ability to obtain complete genotypes in all sample types except those exposed to 80 degrees C for 12-48 days. Finally, comparison of genotype results from the PowerPlex 16 System with other commercially available systems on non-probative reference and forensic samples showed consistent results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号