首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.  相似文献   

2.
Li L  Chen GH  Li CT  Liu Y  Lin Y  Que TZ  Zhao ZM  Wang YX 《法医学杂志》2006,22(2):111-116
目的建立18个基因座的PCR扩增检测试剂盒。方法采用两个多重PCR体系和四色荧光素标记技术,对Amelogenin和17个STR基因座(D3S1358、vWA、FGA、D8S1179、D21S11、D18S51、D5S818、D13S317、D16S539、TH01、TPOX、CSF1PO、D7S820、D2S1338、D19S433、D12S391和D19S253)进行基因型检测,并对其可靠性、稳定性、效能等进行研究。结果通过2个多重PCR扩增体系,可以成功地对各类生物学检材的Amelogenin和17个STR基因座进行检测,且可靠、稳定、高效。结论本研究所研制的试剂盒,是对该18个基因座进行检测的高效、稳定、可靠的新体系。  相似文献   

3.
In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.  相似文献   

4.
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.  相似文献   

5.
目的依据分型图谱,直观、简便识别是否存在Amelogenin基因Y片段丢失的可能。方法采用计算分型图谱中等位基因峰高之和比值的方法,统计1 968份人员样本经Power Plex~ 21试剂盒扩增后Amelogenin与D3S1358基因座之间的均衡性、Amelogenin X等位基因与Amelogenin Y等位基因的均衡性以及D3S1358基因座不同等位基因的均衡性情况。结果 90.8%的女性样本Amelogenin X等位基因峰高不低于D3S1358基因座等位基因峰高和的60%,94.9%的男性样本Amelogenin X等位基因的峰高不超过D3S1358基因座等位基因峰高和的70%。结论 Power Plex~ 21试剂盒扩增后的分型结果中,当Amelogenin基因只检测到Amelogenin X等位基因,且Amelogenin X等位基因的峰高不及D3S1358基因座等位基因峰高之和的70%时,应考虑存在Y片段丢失的可能性。  相似文献   

6.
青岛地区汉族人群13个STR基因座的频率分布及法医学应用   总被引:9,自引:0,他引:9  
目的 调查青岛地区汉族人群无关个体的 13个STR基因座 (D3S135 8、VWA、FGA、D8S1179、D2 1S11、D18S5 1、D5S818、D13S317、D7S82 0、D16S5 39、TH0 1、TPOX、CSFIPO)的基因频率分布 ,研究其遗传多态性及其在法医学个体识别及亲子鉴定中的应用价值。 方法 用美国ABI - 310型遗传分析仪对ProfilerPlus和Cofiler两个系统的 13个STR基因座的复合扩增产物进行毛细管电泳及四色荧光自动分析检测 ,基因分型软件为GeneScanv3.1和Genotyperv2 .5 .2。  结果 获得 13个STR基因座在青岛地区汉族人群的基因频率分布数据 ,13个STR基因座的PIC >0 .5 ,DP >0 .71,CCE =0 .999999,TDP值接近 1,TPm =1.2× 10 -14 ,家系调查符合孟德尔遗传规律。 结论 ProfilerPlus和Cofiler两个系统的 13个STR基因座在法医学个体识别及亲子鉴定中具有较高的应用价值。  相似文献   

7.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

8.
Analysis of length polymorphism at short tandem repeat (STR) loci utilizing the polymerase chain reaction (PCR) process has proven to be an ideal assay for human identification purposes. The short length of STR loci coupled with the amplification of target sequence through PCR allows for a robust, sensitive, and specific assay for highly polymorphic markers. A multiplex containing fifteen STR loci plus the gender-determining locus Amelogenin was developed to provide a single amplification/detection of all CODIS (Combined DNA Index System) STR loci (CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA) as well as two internationally-accepted STRs (D2S1338 and D19S433). By incorporating five-dye fragment analysis technology and non-nucleotide linkers, previously optimized AmpFlSTR kit primer sequences have been maintained. This kit has been developed in accordance with the standards of the forensic community as defined by the DNA Advisory Board. Validation studies were performed to include developmental validation, and the results support the use of the AmpFlSTR Identifiler PCR Amplification Kit for human identity and parentage testing.  相似文献   

9.
Validation of a 16-locus fluorescent multiplex system   总被引:24,自引:0,他引:24  
STR multiplexes have been indispensable for the efficient genotyping of forensic samples. The PowerPlex 16 System contains the coreCODIS loci, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, THOI, TPOX, vWA, the sex determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. This multiplex satisfies the locus requirements for most national databases and is the most efficient currently available system due to its single PCR amplification. To provide the groundwork for judicial acceptance, including the publication of primer sequences, and to evaluate laboratory-to-laboratory variation, a developmental validation for casework on this commercially available system was performed in 24 laboratories and produced the following conclusions. Amplification was reliable on a variety of thermal cyclers and product could be analyzed on either an ABI PRISM 310 Genetic Analyzer or an ABI PRISM 377 DNA Sequencer. Genotyping using single source samples was consistent between 0.25 and 2 ng of input DNA template with a few laboratories obtaining complete genotypes at 0.0625 ng. However, heterozygote allele imbalance (<60% peak height balance) caused by stochastic effects was observed at a rate of 13% with 0.125 ng DNA and 22% at 0.0625 ng DNA. Mixture analyses were done using a total of 1 ng of DNA template. Most alleles were detected in mixtures of 4 to 1 and some minor alleles were detected in mixtures of 19 to 1. Optimum amplification cycle number was dependent on the sensitivity of the detection instrument used and could also be adjusted to accommodate larger amounts of DNA on solid supports such as FTA paper. Reaction conditions including volume, annealing temperature, and concentrations of primer, AmpliTaq Gold, and magnesium were shown to be optimal yet robust enough to withstand moderate variations without affecting genotype analysis. Environmental, matrix and standard source analyses revealed an ability to obtain complete genotypes in all sample types except those exposed to 80 degrees C for 12-48 days. Finally, comparison of genotype results from the PowerPlex 16 System with other commercially available systems on non-probative reference and forensic samples showed consistent results.  相似文献   

10.
A population study of Caucasians residing in Maine was conducted using the AmpF1STR Profiler PCR Amplification Kit and the AmpF1STR Profiler Plus PCR Amplification Kit (Applied Biosystems Division (ABD) of Perkin Elmer, Foster City, CA). The kits contain the reagents necessary to amplify 12 different STR loci and the gender marker Amelogenin using two multiplex PCR, each containing nine STR loci. Thus, there is an overlap of six STR loci. The 12 STR loci are TH01, TPOX, CSF1PO, D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820. These loci represent 12 of the 13 core loci selected by the CODIS STR standardization project. Dye-labeled amplification products were separated and detected using the capillary electrophoresis instrument ABI Prism 310 Genetic Analyzer. Allele frequencies were determined for the 12 STR loci. Statistical analysis of the data included Hardy-Weinburg equilibrium (HWE) analysis, pairwise independence testing, power of discrimination (PD), and probability of exclusion (PE).  相似文献   

11.
A multiplex PCR was developed for the analysis of the sex-determining gene Amelogenin, four conventional STR (short tandem repeat; THO1, D18S51, D21S11 and FGA) loci with a reduced amplicon size and four miniSTR loci (D1S1677, D2S441, D10S1248 and D22S1045). A concordance study in a population of 198 Belgians revealed no differences for the conventional STR loci while a sensitivity study showed a reproducible DNA profile with as low as 30 pg of input DNA.  相似文献   

12.
目的建立扩增片段<135bp,包括D5S818,D8S1179,D16S539 3个miniSTR基因座复合扩增系统。方法采用不同荧光染料标记引物,通过PCR扩增,利用ABI 3100遗传分析仪进行片段长度分析,对100份无关个体血样,10个家系样本以及30份高度降解检材进行检测。结果本系统DNA分型结果与AmpFLSTR Identifiler试剂盒完全一致,且灵敏度高于AmpFLSTR Identifiler试剂盒。结论本系统可以应用于个人识别和亲权鉴定,为降解DNA样本分型提供了新的方法。  相似文献   

13.
目的基于重组质粒制备可用于校准法医STR分型的阳性参照物。方法以常用阳性参照物9948人类基因组DNA STR分型为依据,基于重组质粒构建包含CSF1PO、D7S820、TH01等40个常染色体位点,DYS391、DYS522、DYS385a/b等22个Y染色体位点以及性别判定基因座Amelogenin的STR分型阳性参照物。将重组质粒定量、稀释后等比例混合,分别应用于DNATyper~?19、DNATyper~?24、DNATyper~?Y、Amp F?STR~?Identifiler~?Plus以及Power Plex~?18D System五种扩增试剂盒。结果阳性参照物中各重组质粒浓度为0.01pg/μL~0.001pg/μL;应用于Amp F?STR~?Identifiler~?Plus PCR扩增试剂盒,基于重组质粒制备的阳性参照物与人类基因组DNA扩增检测结果差异较小;将此阳性参照物分别应用于不同公司、不同STR基因座的四种STR扩增试剂盒,电泳检测图谱显示各基因座基因型完整,分型正确,峰高相当,基因座间均衡性良好。结论基于重组质粒制备STR分型阳性参照物,是一种可以替代细胞系制备阳性参照物的方法,具有一定的参考价值。基于此方法制备的阳性参照物可适用于市面上常用的STR检验试剂盒,普适性较强,对法医DNA分型检测有一定的实用价值。  相似文献   

14.
A combination of four Y-specific polymorphic STR loci was amplified simultaneously using fluorescently labeled primers. Multiplex conditions required optimization to eliminate constant bands and amplification products for female DNA. A series of experiments was carried out for mixtures of DNA from two males, and from male and female individuals for the Y-specific STRs and an autosomal locus. For the male/male mixtures amplified with the Y specific system, and amplified for an autosomal locus, the minor component in the mixture could only be identified up to a ratio of 1:10, 1:50 respectively. In male/female DNA mixtures the Y STR alleles could be identified for the highest ratio tested, 400 pg male in DNA in 800 ng female DNA which amounts to a ratio of 1:2000.  相似文献   

15.
Allele frequencies for the nine tetrameric short tandem repeats (STR) loci D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820 (AmpFlSTR Profiler Plus PCR amplification kit, PE Applied Biosystems) and two pentameric STR loci Penta D and Penta E (PowerPlex 16 system, Promega Corporation) were determined in a population sample of unrelated China Han.  相似文献   

16.
PowerPlex~(TM) 16体系在中国人群中罕见等位基因及其类型   总被引:1,自引:2,他引:1  
目的 分析PowerPlexTM 16体系基因座在中国人群中的罕见等位基因及其类型。方法 应用PCR-STR和DNA序列分析技术,对4650个无关个体在15个STR基因座中的罕见等位基因进行检测。结果 在PowerPlexTM16体系中的D7S820、D16S539、Penta E基因座,检测到2种类型的罕见等位基因,而TH01、D21S11、D5S818、D13S317、Penta D、D8S1179、TPOX、FGA基因座检测出1种类型。其等位基因频率均较低(0.215‰-7.097‰)。结论 超出ladder范围的罕见等位基因序列比相邻等位基因增加(或减少)1个或数个重复单位,因碱基的插入或缺失的罕见等位基因出现在两等位基因之间。  相似文献   

17.
The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.  相似文献   

18.
Allele frequencies for the 15 STR locus of PowerPlex 16 were analyzed in 95 healthy unrelated individuals belonging to five important population groups inhabiting different part of India. Fifteen loci studied are Penta E, D18S51, D21S11, THO1,D3S1358, FGA, TPOX, D8S1179, vWA, Amelogenin, Penta D, CSF1PO, D16S539, D7S820, D13S317 and D5S818. In addition of all tetra nucleotide loci, two penta nucleotide loci Penta D and Penta E of the studied system are also found highly polymorphic in all the five studied populations of India. These loci are found highly informative in solving paternity cases and other forensic testing in studied population.  相似文献   

19.
Allele frequencies for three tetrameric short tandem repeat (STR) loci D3S1358, HUMVWA, and HUMFGA were determined in a Slovene Caucasian population sample. DNA samples from a total of 221 Slovenes were amplified by multiplex PCR using the commercial kit AmpFISTR Blue (Perkin-Elmer). Separation and detection of the amplified STR fragments were carried out using a 377 automated genetic analyzer (Applied Biosystem Division/Perkin Elmer). Seven alleles at the D3S1358 locus, 8 alleles at the HUMVWA31A locus, and 13 alleles at the HUMFGA locus were observed. A deviation from Hardy-Weinberg equilibrium was observed, only at the HUMVWA31A locus (p = 0.045, exact test). The departure at this locus was not significant after Bonferroni correction. There were no detectable departures between pairwise comparisons of the loci. The combined power of discrimination for all three loci is 0.9998, and the power of exclusion is 0.9526. The observed allele frequencies for the loci D3S1358, HUMVWA31A, and HUMFGA are similar to those in European and U.S. Caucasian populations.  相似文献   

20.
荧光标记复合扩增STR检测技术在法医学中的应用   总被引:2,自引:0,他引:2  
本研究用荧光标记8个STR位点及性别位点,于同一试管同步进行扩增后,在PE377全自动测序仪于一个泳道内,成功地对各位点进行基因型分离检测.将此方法应用于30多起案件检验,均取得满意结果.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号